Lps-Rk
2510
Part #:GE RT1J
- THERMAL, BIMETALLIC FIXED HEATER, ADJUSTABLE TRIP TYPE 690 V CONTACT RATING UL (CANADA AND US), CSA C22.2, CE APPROVAL 1-PHASE APPLICATION CONTACTOR/PANEL MOUNTING 3 POLE(S) SCREW TERMINAL TYPE 1NO-1NC AUXILIARY CONTACT 1.8 TO 2.7 AMPERE MOTOR FLA AUTOMATIC/MANUAL RESET TYPE YES HEATER INCLUDED COMPENSATED AMBIENT TEMPERATURE CLASS 10A TRIP CLASS APPLICABLE STANDARD IEC/EN 60947-4-1, IEC/EN 60947-5-1, VDE 0660 USED ON CL00/CL01/CL02/CL25/CL03/CL04/CL45 SERIES CONTACTOR MAXIMUM CIRCUIT BREAKER CURRENT RATING 15 AMPERE RT MODEL
$
55.00
Qty:
Part #:GE RT1L
- THERMAL, BIMETALLIC FIXED HEATER, ADJUSTABLE TRIP TYPE 690 V CONTACT RATING UL (CANADA AND US), CSA C22.2, CE APPROVAL 1-PHASE APPLICATION CONTACTOR/PANEL MOUNTING 3 POLE(S) SCREW TERMINAL TYPE 1NO-1NC AUXILIARY CONTACT 4 TO 6.3 AMPERE MOTOR FLA AUTOMATIC/MANUAL RESET TYPE YES HEATER INCLUDED COMPENSATED AMBIENT TEMPERATURE CLASS 10A TRIP CLASS APPLICABLE STANDARD IEC/EN 60947-4-1, IEC/EN 60947-5-1, VDE 0660 USED ON CL00/CL01/CL02/CL25/CL03/CL04/CL45 SERIES CONTACTOR MAXIMUM CIRCUIT BREAKER CURRENT RATING 15 AMPERE RT MODEL
$
55.00
Qty:
Part #:GE RT1M
- THERMAL, BIMETALLIC FIXED HEATER, ADJUSTABLE TRIP TYPE 690 V CONTACT RATING UL (CANADA AND US), CSA C22.2, CE APPROVAL 1 PHASE APPLICATION CONTACTOR MOUNTING 3 POLE(S) SCREW TERMINAL TYPE 1NO-1NC AUXILIARY CONTACT 5.5 TO 8.5 AMPERE MOTOR FLA AUTOMATIC/MANUAL RESET TYPE YES HEATER INCLUDED COMPENSATED AMBIENT TEMPERATURE CLASS 10A TRIP CLASS APPLICABLE STANDARD IEC/EN 60947-4-1, IEC/EN 60947-5-1, VDE 0660 USED ON CL00/CL01/CL02/CL25/CL03/CL04/CL45 SERIES CONTACTOR MAXIMUM CIRCUIT BREAKER CURRENT RATING 15 AMPERE RT MODEL
$
57.00
Qty:
Part #:GE RT1P
- THERMAL, BIMETALLIC FIXED HEATER, ADJUSTABLE TRIP TYPE 690 V CONTACT RATING UL (CANADA AND US), CSA C22.2, CE APPROVAL 1-PHASE APPLICATION CONTACTOR/PANEL MOUNTING 3 POLE(S) SCREW TERMINAL TYPE 1NO-1NC AUXILIARY CONTACT 10 TO 16 AMPERE MOTOR FLA AUTOMATIC/MANUAL RESET TYPE YES HEATER INCLUDED COMPENSATED AMBIENT TEMPERATURE CLASS 10A TRIP CLASS APPLICABLE STANDARD IEC/EN 60947-4-1, IEC/EN 60947-5-1, VDE 0660 USED ON CL00/CL01/CL02/CL25/CL03/CL04/CL45 SERIES CONTACTOR MAXIMUM CIRCUIT BREAKER CURRENT RATING 35 AMPERE RT MODEL
$
57.00
Qty:
Part #:BUSS LPS-RK-50SP
- CLASS RK1 TYPE 5.5 INCH UL 248-12, CSA C22.2, CE APPROVAL 600 VOLT AC, 300 VOLT DC VOLTAGE RATING 1.06 INCH DIAMETER 300 KILOAMP SYMMETRICAL, 100 KILOAMP (DC) INTERRUPTING RATING 50 AMP CURRENT RATING FERRULE WITH GROOVED RING TERMINAL TYPE 10 SECOND TIME DELAY AT 500 PERCENT RATED LOAD, DUAL ELEMENT, NON-INDICATING CHARACTERISTICS LOW-PEAK[TM] BRAND CONTACT MATERIAL SILVER PLATED APPLICATION LARGE DISTRIBUTION SWITCHBOARD, POWER PANELBOARD, MOTOR CONTROL CENTER, MACHINERY DISCONNECT SWITCH LPS-RK MODEL
$
106.36
Qty:
Part #:3M 2510-3/4X60FT
-
Straight-cut, woven, cotton-cloth backing is oil-primed and coated with yellow, electrical, insulating varnish
Excellent dielectric strength
Suitable for insulating bus bars, motor leads and service drop connections
Wide and narrow width electrical tape available (0.75 in &ndash 2 in.)
Temperature stable with an operating range of 32°F (0°C) to 220°F (105°C)
Withstands a temperature range of 32 to 221 degrees F (0 to 105 degrees C)
Withstands a temperature range of 32 to 221 degrees F (0 to 105 degrees C)
ASTM Approved and RoHS 2011/65/EU Compliant
Yellow, varnish coated cotton cloth, no adhesive. Insulate bus bars, motor leads (for re-entry), service drop connections.
Scotch® Tape 2510 has a straight-cut, woven cotton, cambric fabric backing that provides high tensile strength and ruggedness. This fabric is coated and oil-primed with yellow electrical insulating varnish. This moisture-resistant tape offers excellent dielectric strength with cut-through and puncture resistance. ASTM Approved and RoHS 2011/65/EU Compliant.
$
59.78
Qty:
Part #:GE RT1K
- THERMAL, BIMETALLIC FIXED HEATER, ADJUSTABLE TRIP TYPE 690 V CONTACT RATING UL (CANADA AND US), CSA C22.2, CE APPROVAL 1-PHASE APPLICATION CONTACTOR/PANEL MOUNTING 3 POLE(S) SCREW TERMINAL TYPE 1NO-1NC AUXILIARY CONTACT 2.5 TO 4 AMPERE MOTOR FLA AUTOMATIC/MANUAL RESET TYPE YES HEATER INCLUDED COMPENSATED AMBIENT TEMPERATURE CLASS 10A TRIP CLASS APPLICABLE STANDARD IEC/EN 60947-4-1, IEC/EN 60947-5-1, VDE 0660 USED ON CL00/CL01/CL02/CL25/CL03/CL04/CL45 SERIES CONTACTOR MAXIMUM CIRCUIT BREAKER CURRENT RATING 15 AMPERE RT MODEL
$
55.00
Qty:
Part #:BUSS LPS-RK-200SP
- CLASS RK1 TYPE 9.63 INCH UL 248-12, CSA C22.2, CE APPROVAL 600 VAC/300 VDC VOLTAGE RATING 1.66 INCH DIAMETER 300 KILOAMPERE (SYMMETRICAL), 100 KILOAMPERE (DC) INTERRUPTING RATING 200 AMPERE CURRENT RATING BLADE TERMINAL TYPE 10 SEC TIME DELAY (AT 500 PERCENT RATED LOAD), DUAL ELEMENT, NON-INDICATING CHARACTERISTICS LOW-PEAK[TM] BRAND APPLICATION LARGE DISTRIBUTION SWITCHBOARD, POWER PANELBOARD, MOTOR CONTROL CENTER, MACHINERY DISCONNECT SWITCH SERIES LPS-RK MODEL
$
535.94
Qty:
Part #:BUSS LPS-RK-25SP
- CLASS RK1 TYPE 5 INCH UL 248-12, CSA C22.2, CE APPROVAL 600 VAC/300 VDC VOLTAGE RATING 0.81 INCH DIAMETER 300 KILOAMPERE (SYMMETRICAL), 100 KILOAMPERE (DC) INTERRUPTING RATING 25 AMPERE CURRENT RATING FERRULE WITH GROOVED RING TERMINAL TYPE 8 SEC TIME DELAY (AT 500 PERCENT RATED LOAD), DUAL ELEMENT, NON-INDICATING CHARACTERISTICS LOW-PEAK[TM] BRAND APPLICATION LARGE DISTRIBUTION SWITCHBOARD, POWER PANELBOARD, MOTOR CONTROL CENTER, MACHINERY DISCONNECT SWITCH SERIES LPS-RK MODEL
$
75.26
Qty:
Part #:BUSS LPS-RK-30SP
- CLASS RK1 TYPE 5 INCH UL 248-12, CSA C22.2, CE APPROVAL 600 VAC/300 VDC VOLTAGE RATING 0.81 INCH DIAMETER 300 KILOAMPERE (SYMMETRICAL), 100 KILOAMPERE (DC) INTERRUPTING RATING 30 AMPERE CURRENT RATING FERRULE WITH GROOVED RING TERMINAL TYPE 8 SEC TIME DELAY (AT 500 PERCENT RATED LOAD), DUAL ELEMENT, NON-INDICATING CHARACTERISTICS LOW-PEAK[TM] BRAND APPLICATION LARGE DISTRIBUTION SWITCHBOARD, POWER PANELBOARD, MOTOR CONTROL CENTER, MACHINERY DISCONNECT SWITCH SERIES LPS-RK MODEL
$
75.26
Qty: