Part #:3M 2510-3/4X60FT

Straight-cut, woven, cotton-cloth backing is oil-primed and coated with yellow, electrical, insulating varnish Excellent dielectric strength Suitable for insulating bus bars, motor leads and service drop connections Wide and narrow width electrical tape available (0.75 in &ndash 2 in.) Temperature stable with an operating range of 32&degF (0&degC) to 220&degF (105&degC) Withstands a temperature range of 32 to 221 degrees F (0 to 105 degrees C) Withstands a temperature range of 32 to 221 degrees F (0 to 105 degrees C) ASTM Approved and RoHS 2011/65/EU Compliant Yellow, varnish coated cotton cloth, no adhesive. Insulate bus bars, motor leads (for re-entry), service drop connections. Scotch&reg Tape 2510 has a straight-cut, woven cotton, cambric fabric backing that provides high tensile strength and ruggedness. This fabric is coated and oil-primed with yellow electrical insulating varnish. This moisture-resistant tape offers excellent dielectric strength with cut-through and puncture resistance. ASTM Approved and RoHS 2011/65/EU Compliant.
$ 59.78
Part #:INT-MAT T104

24 HR TYPE DRAWN STEEL MATERIAL 5 INCH W X 3 INCH D X 7 3/4 INCH H SIZE GRAY FINISH 1 HR MIN. OFF TIME 1 HR MIN. ON TIME CSA (CANADA AND US), CSA C22.2 APPROVAL INDOOR/OUTDOOR LIGHTING, POST LANTERN, SIGN, POOL HEATER, FILTER, HYDROCHLORINATOR, AIR CONDITIONING, BLOWER, ELECTRIC FENCE, PUMP, HEATING/VENTILATING SYSTEM, MUSIC AND SIGNAL SYSTEM, FAN, POULTRY FOGGER, CONVEYER APPLICATION 208 TO 277 VAC AT 60 HZ VOLTAGE RATING NEMA 1 ENCLOSURE 40 AMPERE (RESISTIVE/TUNGSTEN) CURRENT RATING 5 HP AT 240 VAC SINGLE PHASE (28 FLA), 1000 VA (PILOT DUTY) POWER RATING -40 TO 130 DEG F OPERATING TEMPERATURE DPST SWITCH TYPE NO RESERVE POWER INTERMATIC[R] BRAND WITH ON/OFF TRIPPER T100 MODEL
$ 144.46
Part #:INT-MAT T101R

24 HR TYPE DRAWN STEEL MATERIAL 5 1/2 INCH W X 3 5/8 INCH D X 9 3/8 INCH H SIZE GRAY FINISH 1 HR MIN. OFF TIME 1 HR MIN. ON TIME CSA (CANADA AND US), CSA C22.2 APPROVAL INDOOR/OUTDOOR LIGHTING, POST LANTERN, SIGN, POOL HEATER, FILTER, HYDROCHLORINATOR, AIR CONDITIONING, BLOWER, ELECTRIC FENCE, PUMP, HEATING/VENTILATING SYSTEM, MUSIC AND SIGNAL SYSTEM, FAN, POULTRY FOGGER, CONVEYER APPLICATION 125 VAC AT 60 HZ VOLTAGE RATING NEMA 3R ENCLOSURE 40 AMPERE (RESISTIVE/TUNGSTEN) CURRENT RATING 2 HP AT 120 VAC (24 FLA), 1000 VA (PILOT DUTY) POWER RATING -40 TO 130 DEG F OPERATING TEMPERATURE SPST SWITCH TYPE NO RESERVE POWER INTERMATIC[R] BRAND WITH ON/OFF TRIPPER T100 MODEL
$ 197.28
Part #:INT-MAT T104R

24 HR TYPE DRAWN STEEL MATERIAL 5 1/2 INCH W X 3 5/8 INCH D X 9 3/8 INCH H SIZE GRAY FINISH 1 HR MIN. OFF TIME 1 HR MIN. ON TIME CSA (CANADA AND US), CSA C22.2 APPROVAL INDOOR/OUTDOOR LIGHTING, POST LANTERN, SIGN, POOL HEATER, FILTER, HYDROCHLORINATOR, AIR CONDITIONING, BLOWER, ELECTRIC FENCE, PUMP, HEATING/VENTILATING SYSTEM, MUSIC AND SIGNAL SYSTEM, FAN, POULTRY FOGGER, CONVEYER APPLICATION 208 TO 277 VAC AT 60 HZ VOLTAGE RATING NEMA 3R ENCLOSURE 40 AMPERE (RESISTIVE/TUNGSTEN) CURRENT RATING 5 HP AT 240 VAC SINGLE PHASE (28 FLA), 1000 VA (PILOT DUTY) POWER RATING -40 TO 130 DEG F OPERATING TEMPERATURE DPST SWITCH TYPE NO RESERVE POWER INTERMATIC[R] BRAND WITH ON/OFF TRIPPER T100 MODEL
$ 191.76
Part #:GE THQL2120

MOLDED CASE, FIXED THERMAL MAGNETIC, INTERNAL COMMON TRIP TYPE 2 INCH WIDTH X 2-3/8 INCH DEPTH X 3-9/32 INCH HEIGHT SIZE AL SERIES PANELBOARD USED ON 14 TO 8 AWG (COPPER), 12 TO 8 AWG (ALUMINUM) WIRE SIZE UL APPROVAL 120/240 VOLT AC VOLTAGE RATING 1 INCH PLUG-IN MOUNTING 10 KILOAMP INTERRUPTING RATING 20 AMP CURRENT RATING 2 POLE(S) COPPER/ALUMINUM LOAD LUG TERMINAL TYPE TRIP TYPE NON-INTERCHANGEABLE FRAME TYPE THQL TRIP FUNCTION LI APPLICATION HEATING, AIR CONDITIONING, REFRIGERATION THQL MODEL
$ 48.00
Part #:GE THQL2140

MOLDED CASE, FIXED THERMAL MAGNETIC, INTERNAL COMMON TRIP TYPE 2 INCH WIDTH X 2-3/8 INCH DEPTH X 3-9/32 INCH HEIGHT SIZE AL SERIES PANELBOARD USED ON 8 TO 3 AWG (COPPER/ALUMINUM) WIRE SIZE UL APPROVAL 120/240 VOLT AC VOLTAGE RATING 1 INCH PLUG-IN MOUNTING 10 KILOAMP INTERRUPTING RATING 40 AMP CURRENT RATING 2 POLE(S) COPPER/ALUMINUM LOAD LUG TERMINAL TYPE TRIP TYPE NON-INTERCHANGEABLE FRAME TYPE THQL TRIP FUNCTION LI APPLICATION HEATING, AIR CONDITIONING, REFRIGERATION THQL MODEL
$ 53.00
Part #:GE THQB2115

MOLDED CASE, FIXED THERMAL MAGNETIC, INTERNAL COMMON TRIP TYPE 2 INCH W X 2-3/8 INCH D X 3-9/32 INCH H SIZE AQ SERIES PANELBOARD USED ON 14 TO 8 AWG (COPPER)/12 TO 8 AWG (ALUMINUM) WIRE SIZE UL APPROVAL 120/240 VAC VOLTAGE RATING 1 INCH BOLT-ON MOUNTING 10 KILOAMPERE INTERRUPTING RATING 15 AMPERE CURRENT RATING 2 POLE(S) COPPER/ALUMINUM LOAD LUG, BOLT-ON TERMINAL TYPE TRIP TYPE NON-INTERCHANGEABLE FRAME TYPE THQB TRIP FUNCTION LI APPLICATION HEATING, AIR CONDITIONING, REFRIGERATION SERIES THQB MODEL
$ 78.00
Part #:GE THQB2150

MOLDED CASE, FIXED THERMAL MAGNETIC, INTERNAL COMMON TRIP TYPE 2 INCH W X 2-3/8 INCH D X 3-9/32 INCH H SIZE AQ SERIES PANELBOARD USED ON 8 TO 3 AWG (COPPER/ALUMINUM) WIRE SIZE UL APPROVAL 120/240 VAC VOLTAGE RATING 1 INCH BOLT-ON MOUNTING 10 KILOAMPERE INTERRUPTING RATING 50 AMPERE CURRENT RATING 2 POLE(S) COPPER/ALUMINUM LOAD LUG, BOLT-ON TERMINAL TYPE TRIP TYPE NON-INTERCHANGEABLE FRAME TYPE THQB TRIP FUNCTION LI APPLICATION HEATING, AIR CONDITIONING, REFRIGERATION SERIES THQB MODEL
$ 78.00
Part #:GE THQP220

MOLDED CASE, FIXED THERMAL MAGNETIC, INTERNAL COMMON TRIP TYPE 1 INCH WIDTH X 2-3/8 INCH DEPTH X 3-9/32 INCH HEIGHT SIZE 14 TO 8 AWG (COPPER), 12 TO 8 AWG (ALUMINUM) WIRE SIZE UL APPROVAL 120/240 VOLT AC VOLTAGE RATING 1/2 INCH PLUG-IN MOUNTING 10 KILOAMP INTERRUPTING RATING 20 AMP CURRENT RATING 2 POLE(S) COPPER/ALUMINUM LOAD LUG TERMINAL TYPE TRIP TYPE NON-INTERCHANGEABLE FRAME TYPE THQP TRIP FUNCTION LI APPLICATION HEATING, AIR CONDITIONING, REFRIGERATION THQP MODEL
$ 48.00
Part #:GE THQB2120

MOLDED CASE, FIXED THERMAL MAGNETIC, INTERNAL COMMON TRIP TYPE 2 INCH WIDTH X 2-3/8 INCH DEPTH X 3-9/32 INCH HEIGHT SIZE AQ SERIES PANELBOARD USED ON 14 TO 8 AWG (COPPER), 12 TO 8 AWG (ALUMINUM) WIRE SIZE UL APPROVAL 120/240 VOLT AC VOLTAGE RATING 1 INCH BOLT-ON MOUNTING 10 KILOAMP INTERRUPTING RATING 20 AMP CURRENT RATING 2 POLE(S) COPPER/ALUMINUM LOAD LUG TERMINAL TYPE TRIP TYPE NON-INTERCHANGEABLE FRAME TYPE THQB TRIP FUNCTION LI APPLICATION HEATING, AIR CONDITIONING, REFRIGERATION THQB MODEL
$ 78.00
Part #:GE THQB2160

MOLDED CASE, FIXED THERMAL MAGNETIC, INTERNAL COMMON TRIP TYPE 2 INCH WIDTH X 2-3/8 INCH DEPTH X 3-9/32 INCH HEIGHT SIZE AQ SERIES PANELBOARD USED ON 8 TO 3 AWG (COPPER/ALUMINUM) WIRE SIZE UL APPROVAL 120/240 VOLT AC VOLTAGE RATING 1 INCH BOLT-ON MOUNTING 10 KILOAMP INTERRUPTING RATING 60 AMP CURRENT RATING 2 POLE(S) COPPER/ALUMINUM LOAD LUG TERMINAL TYPE TRIP TYPE NON-INTERCHANGEABLE FRAME TYPE THQB TRIP FUNCTION LI APPLICATION HEATING, AIR CONDITIONING, REFRIGERATION THQB MODEL
$ 78.00
Part #:INT-MAT T101

24 HR TYPE DRAWN STEEL MATERIAL 5 INCH W X 3 INCH D X 7 3/4 INCH H SIZE GRAY FINISH 1 HR MIN. OFF TIME 1 HR MIN. ON TIME CSA (CANADA AND US), CSA C22.2 APPROVAL INDOOR/OUTDOOR LIGHTING, POST LANTERN, SIGN, POOL HEATER, FILTER, HYDROCHLORINATOR, AIR CONDITIONING, BLOWER, ELECTRIC FENCE, PUMP, HEATING/VENTILATING SYSTEM, MUSIC AND SIGNAL SYSTEM, FAN, POULTRY FOGGER, CONVEYER APPLICATION 125 VAC AT 60 HZ VOLTAGE RATING NEMA 1 ENCLOSURE 40 AMPERE (RESISTIVE/TUNGSTEN) CURRENT RATING 2 HP AT 120 VAC (24 FLA), 1000 VA (PILOT DUTY) POWER RATING -40 TO 130 DEG F OPERATING TEMPERATURE SPST SWITCH TYPE NO RESERVE POWER INTERMATIC[R] BRAND WITH ON/OFF TRIPPER T100 MODEL
$ 155.26
 