Part #:BUSS FRN-R-125

CLASS RK5 TYPE 7.13 INCH UL 248-12, CSA C22.2, CE APPROVAL 250 VOLT AC, 125 VOLT DC VOLTAGE RATING 1.56 INCH DIAMETER 200 KILOAMP SYMMETRICAL (AC), 20 KILOAMP (DC) INTERRUPTING RATING 125 AMP CURRENT RATING BLADE TERMINAL TYPE 10 SECOND TIME DELAY AT 500 PERCENT RATED LOAD, DUAL ELEMENT, NON-INDICATING CHARACTERISTICS FUSETRON[TM] BRAND APPLICATION POWER PANELBOARD, MOTOR CONTROL CENTER, COMBINATION STARTER, MACHINERY DISCONNECT FRN-R MODEL
$ 229.84
Part #:BUSS FRS-R-300

CLASS RK5 TYPE 11.63 INCH UL 248-12, CSA C22.2, CE APPROVAL 600 VOLT AC, 300 VOLT DC VOLTAGE RATING 2.34 INCH DIAMETER 200 KILOAMP SYMMETRICAL (AC), 20 KILOAMP (DC) INTERRUPTING RATING 300 AMP CURRENT RATING BLADE TERMINAL TYPE 10 SECOND TIME DELAY AT 500 PERCENT RATED LOAD, DUAL ELEMENT, NON-INDICATING CHARACTERISTICS FUSETRON[TM] BRAND APPLICATION POWER PANELBOARD, MOTOR CONTROL CENTER, COMBINATION STARTER, MACHINERY DISCONNECT FRS-R MODEL
$ 707.80
Part #:BUSS FRN-R-15

CLASS RK5 TYPE 2 INCH UL 248-12, CSA C22.2, CE APPROVAL 250 VAC/125 VDC VOLTAGE RATING 0.56 INCH DIAMETER 200 KILOAMPERE (SYMMETRICAL), 20 KILOAMPERE (DC) INTERRUPTING RATING 15 AMPERE CURRENT RATING FERRULE WITH GROOVED RING TERMINAL TYPE 10 SEC TIME DELAY (AT 500 PERCENT RATED LOAD), DUAL ELEMENT, NON-INDICATING CHARACTERISTICS FUSETRON[TM] BRAND APPLICATION POWER PANELBOARD, MOTOR CONTROL CENTER, COMBINATION STARTER, MACHINERY DISCONNECT SERIES FRN-R MODEL
$ 24.08
Part #:BUSS FRN-R-40

CLASS RK5 TYPE 3 INCH UL 248-12, CSA C22.2, CE APPROVAL 250 VAC/125 VDC VOLTAGE RATING 0.81 INCH DIAMETER 200 KILOAMPERE (SYMMETRICAL), 20 KILOAMPERE (DC) INTERRUPTING RATING 40 AMPERE CURRENT RATING FERRULE WITH GROOVED RING TERMINAL TYPE 10 SEC TIME DELAY (AT 500 PERCENT RATED LOAD), DUAL ELEMENT, NON-INDICATING CHARACTERISTICS FUSETRON[TM] BRAND APPLICATION POWER PANELBOARD, MOTOR CONTROL CENTER, COMBINATION STARTER, MACHINERY DISCONNECT SERIES FRN-R MODEL
$ 39.88
Part #:BUSS FRN-R-45

CLASS RK5 TYPE 3 INCH UL 248-12, CSA C22.2, CE APPROVAL 250 VOLT AC, 125 VOLT DC VOLTAGE RATING 0.81 INCH DIAMETER 200 KILOAMP SYMMETRICAL (AC), 20 KILOAMP (DC) INTERRUPTING RATING 45 AMP CURRENT RATING BLADE TERMINAL TYPE 10 SECOND TIME DELAY AT 500 PERCENT RATED LOAD, DUAL ELEMENT, NON-INDICATING CHARACTERISTICS FUSETRON[TM] BRAND APPLICATION POWER PANELBOARD, MOTOR CONTROL CENTER, COMBINATION STARTER, MACHINERY DISCONNECT FRN-R MODEL
$ 39.88
Part #:BUSS FRN-R-50

CLASS RK5 TYPE 3 INCH UL 248-12, CSA C22.2, CE APPROVAL 250 VOLT AC, 125 VOLT DC VOLTAGE RATING 0.81 INCH DIAMETER 200 KILOAMP SYMMETRICAL (AC), 20 KILOAMP (DC) INTERRUPTING RATING 50 AMP CURRENT RATING BLADE TERMINAL TYPE 10 SECOND TIME DELAY AT 500 PERCENT RATED LOAD, DUAL ELEMENT, NON-INDICATING CHARACTERISTICS FUSETRON[TM] BRAND APPLICATION POWER PANELBOARD, MOTOR CONTROL CENTER, COMBINATION STARTER, MACHINERY DISCONNECT FRN-R MODEL
$ 39.88
Part #:BUSS FRN-R-60

CLASS RK5 TYPE 3 INCH UL 248-12, CSA C22.2, CE APPROVAL 250 VAC/125 VDC VOLTAGE RATING 0.81 INCH DIAMETER 200 KILOAMPERE (SYMMETRICAL), 20 KILOAMPERE (DC) INTERRUPTING RATING 60 AMPERE CURRENT RATING FERRULE WITH GROOVED RING TERMINAL TYPE 10 SEC TIME DELAY (AT 500 PERCENT RATED LOAD), DUAL ELEMENT, NON-INDICATING CHARACTERISTICS FUSETRON[TM] BRAND APPLICATION POWER PANELBOARD, MOTOR CONTROL CENTER, COMBINATION STARTER, MACHINERY DISCONNECT SERIES FRN-R MODEL
$ 39.88
Part #:BUSS FRN-R-5

CLASS RK5 TYPE 2 INCH UL 248-12, CSA C22.2, CE APPROVAL 250 VOLT AC, 125 VOLT DC VOLTAGE RATING 0.56 INCH DIAMETER 200 KILOAMP SYMMETRICAL (AC), 20 KILOAMP (DC) INTERRUPTING RATING 5 AMP CURRENT RATING BLADE TERMINAL TYPE 8 SECOND TIME DELAY AT 500 PERCENT RATED LOAD, DUAL ELEMENT, NON-INDICATING CHARACTERISTICS FUSETRON[TM] BRAND APPLICATION POWER PANELBOARD, MOTOR CONTROL CENTER, COMBINATION STARTER, MACHINERY DISCONNECT FRN-R MODEL
$ 37.98
Part #:BUSS FRN-R-70

CLASS RK5 TYPE 5.88 INCH UL 248-12, CSA C22.2, CE APPROVAL 250 VAC VOLTAGE RATING 1.06 INCH DIAMETER 200 KILOAMPERE (SYMMETRICAL), 20 KILOAMPERE (DC) INTERRUPTING RATING 70 AMPERE CURRENT RATING BLADE TERMINAL TYPE 10 SEC TIME DELAY (AT 500 PERCENT RATED LOAD), DUAL ELEMENT CHARACTERISTICS FUSETRON[TM] BRAND APPLICATION POWER PANELBOARD, MOTOR CONTROL CENTER, COMBINATION STARTER, MACHINERY DISCONNECT SERIES FRN-R MODEL
$ 94.00
Part #:BUSS FRN-R-90

CLASS RK5 TYPE 5.88 INCH UL 248-12, CSA C22.2, CE APPROVAL 250 VOLT AC, 125 VOLT DC VOLTAGE RATING 1.06 INCH DIAMETER 200 KILOAMP SYMMETRICAL (AC), 20 KILOAMP (DC) INTERRUPTING RATING 90 AMP CURRENT RATING BLADE TERMINAL TYPE 10 SECOND TIME DELAY AT 500 PERCENT RATED LOAD, DUAL ELEMENT, NON-INDICATING CHARACTERISTICS FUSETRON[TM] BRAND APPLICATION POWER PANELBOARD, MOTOR CONTROL CENTER, COMBINATION STARTER, MACHINERY DISCONNECT FRN-R MODEL
$ 94.00
Part #:BUSS FRS-R-3

CLASS RK5 TYPE 5 INCH UL 248-12, CSA C22.2, CE APPROVAL 600 VAC/300 VDC VOLTAGE RATING 0.81 INCH DIAMETER 200 KILOAMPERE (SYMMETRICAL), 20 KILOAMPERE (DC) INTERRUPTING RATING 3 AMPERE CURRENT RATING FERRULE WITH GROOVED RING TERMINAL TYPE 10 SEC TIME DELAY (AT 500 PERCENT RATED LOAD), DUAL ELEMENT, NON-INDICATING CHARACTERISTICS FUSETRON[TM] BRAND APPLICATION POWER PANELBOARD, MOTOR CONTROL CENTER, COMBINATION STARTER, MACHINERY DISCONNECT SERIES FRS-R MODEL
$ 53.46
Part #:BUSS FRS-R-5

CLASS RK5 TYPE 5 INCH UL 248-12, CSA C22.2, CE APPROVAL 600 VOLT AC, 300 VOLT DC VOLTAGE RATING 0.81 INCH DIAMETER 200 KILOAMP SYMMETRICAL (AC), 20 KILOAMP (DC) INTERRUPTING RATING 5 AMP CURRENT RATING FERRULE WITH GROOVED RING TERMINAL TYPE 10 SECOND TIME DELAY AT 500 PERCENT RATED LOAD, DUAL ELEMENT, NON-INDICATING CHARACTERISTICS FUSETRON[TM] BRAND APPLICATION POWER PANELBOARD, MOTOR CONTROL CENTER, COMBINATION STARTER, MACHINERY DISCONNECT FRS-R MODEL
$ 53.46
Part #:BUSS FRS-R-8

CLASS RK5 TYPE 5 INCH UL 248-12, CSA C22.2, CE APPROVAL 600 VAC/300 VDC VOLTAGE RATING 0.81 INCH DIAMETER 200 KILOAMPERE (SYMMETRICAL), 20 KILOAMPERE (DC) INTERRUPTING RATING 8 AMPERE CURRENT RATING FERRULE WITH GROOVED RING TERMINAL TYPE 10 SEC TIME DELAY (AT 500 PERCENT RATED LOAD), DUAL ELEMENT, NON-INDICATING CHARACTERISTICS FUSETRON[TM] BRAND APPLICATION POWER PANELBOARD, MOTOR CONTROL CENTER, COMBINATION STARTER, MACHINERY DISCONNECT SERIES FRS-R MODEL
$ 53.46
Part #:BUSS FRS-R-35

CLASS RK5 TYPE 5.5 INCH UL 248-12, CSA C22.2, CE APPROVAL 600 VOLT AC, 250 VOLT DC VOLTAGE RATING 1.06 INCH DIAMETER 200 KILOAMP SYMMETRICAL (AC), 20 KILOAMP (DC) INTERRUPTING RATING 35 AMP CURRENT RATING FERRULE WITH GROOVED RING TERMINAL TYPE 10 SECOND TIME DELAY AT 500 PERCENT RATED LOAD, DUAL ELEMENT, NON-INDICATING CHARACTERISTICS FUSETRON[TM] BRAND APPLICATION POWER PANELBOARD, MOTOR CONTROL CENTER, COMBINATION STARTER, MACHINERY DISCONNECT FRS-R MODEL
$ 81.60
Part #:BUSS FRS-R-50

CLASS RK5 TYPE 5.5 INCH UL 248-12, CSA C22.2, CE APPROVAL 600 VOLT AC, 250 VOLT DC VOLTAGE RATING 1.06 INCH DIAMETER 200 KILOAMP SYMMETRICAL (AC), 20 KILOAMP (DC) INTERRUPTING RATING 50 AMP CURRENT RATING FERRULE WITH GROOVED RING TERMINAL TYPE 10 SECOND TIME DELAY AT 500 PERCENT RATED LOAD, DUAL ELEMENT, NON-INDICATING CHARACTERISTICS FUSETRON[TM] BRAND APPLICATION POWER PANELBOARD, MOTOR CONTROL CENTER, COMBINATION STARTER, MACHINERY DISCONNECT FRS-R MODEL
$ 81.60
Part #:BUSS FRS-R-250

CLASS RK5 TYPE 11.63 INCH UL 248-12, CSA C22.2, CE APPROVAL 600 VAC/300 VDC VOLTAGE RATING 2.59 INCH DIAMETER 200 KILOAMPERE (SYMMETRICAL), 20 KILOAMPERE (DC) INTERRUPTING RATING 250 AMPERE CURRENT RATING BLADE TERMINAL TYPE 10 SEC TIME DELAY (AT 500 PERCENT RATED LOAD), DUAL ELEMENT CHARACTERISTICS FUSETRON[TM] BRAND APPLICATION POWER PANELBOARD, MOTOR CONTROL CENTER, COMBINATION STARTER, MACHINERY DISCONNECT SERIES FRS-R MODEL
$ 707.80
Part #:PAND C1WH6

NON SLIP, SNAP ON TYPE RIGID PVC MATERIAL WHITE FINISH 6 FT 72 LENGTH IN INCH 1 INCH 1 WIDTH IN INCH TYPE E/F/G SLOTTED WALL, TYPE FS/S SOLID WALL, TYPE D ROUND HOLE WALL USED ON 6 LENGTH IN FT 120 FT STANDARD PACKAGE PANDUIT. BRAND LENGTH IN FT - UOM FT LENGTH IN INCH - UOM IN WIDTH IN INCH - UOM IN C1 MODEL
$ 1.64
Part #:PAND C2LG6

NON-SLIP, SNAP-ON TYPE PVC MATERIAL LIGHT GRAY FINISH 6 FOOT 2 INCH TYPE F NARROW SLOTTED WIRING DUCT, G WIDE SLOTTED WIRING DUCT, TYPE D ROUND HOLE WIRING DUCT, TYPE FS SOLID WALL RACEWAY, CORNER WIRING DUCT USED ON UL, CSA, CE APPROVAL 120 PER CARTON STANDARD PACKAGE LEAD-FREE ROHS COMPLIANT
$ 2.56
Part #:PAND C3BL6

NON SLIP, SNAP ON TYPE RIGID PVC MATERIAL BLACK FINISH 6 FT 72 LENGTH IN INCH 3 INCH 3 WIDTH IN INCH TYPE E/G SLOTTED WALL, TYPE FS/S SOLID WALL, TYPE D ROUND HOLE WALL USED ON 6 LENGTH IN FT 120 FT STANDARD PACKAGE PANDUIT. BRAND LENGTH IN FT - UOM FT LENGTH IN INCH - UOM IN WIDTH IN INCH - UOM IN C3 MODEL
$ 3.88
Part #:SIEM5 Q115

MINIATURE, THERMAL AND FIXED MAGNETIC TRIP TYPE 1 INCH WIDTH X 3 INCH DEPTH X 3-1/8 INCH HEIGHT SIZE LOAD CENTER USED ON 14 TO 6 AWG (COPPER/ALUMINUM) WIRE SIZE UL 489 APPROVAL 120 VOLT AC VOLTAGE RATING PLUG-IN MOUNTING 10 KILOAMP INTERRUPTING RATING 15 AMP AT 40 DEG C CURRENT RATING 1 POLE(S) LOAD LUG TERMINAL TYPE SPEEDFAX[TM], INSTA-WIRE BRAND FRAME TYPE QP QP MODEL
$ 78.72
Part #:SIEM5 Q230

MINIATURE, THERMAL AND FIXED MAGNETIC TRIP, COMMON TRIP TYPE 2 INCH WIDTH X 3 INCH DEPTH X 3-1/8 INCH HEIGHT SIZE LOAD CENTER USED ON 14 TO 6 AWG (COPPER/ALUMINUM) WIRE SIZE UL 489 APPROVAL 120/240 VOLT AC VOLTAGE RATING PLUG-IN MOUNTING 10 KILOAMP INTERRUPTING RATING 30 AMP AT 40 DEG C CURRENT RATING 2 POLE(S) LOAD LUG TERMINAL TYPE SPEEDFAX[TM], INSTA-WIRE BRAND FRAME TYPE QP QP MODEL
$ 161.14
Part #:GE EP101ULH3C01

Circuit Breaker, 1 Pole, C-Curve, 1A, UL489, 277V 10kA, 480Y/277VAC, 60/125VDC EP100 UL UL1077 10kA C trip curves 277/480VAC, 50/110VDC
$ 122.00
Part #:SIEM5 Q290

MINIATURE, THERMAL AND FIXED MAGNETIC TRIP, COMMON TRIP TYPE 2 INCH WIDTH X 3 INCH DEPTH X 3-1/8 INCH HEIGHT SIZE LOAD CENTER USED ON 8 TO 2/0 AWG (COPPER/ALUMINUM) WIRE SIZE UL 489 APPROVAL 120/240 VOLT AC VOLTAGE RATING PLUG-IN MOUNTING 10 KILOAMP INTERRUPTING RATING 90 AMP AT 40 DEG C CURRENT RATING 2 POLE(S) LOAD LUG TERMINAL TYPE SPEEDFAX[TM], INSTA-WIRE BRAND FRAME TYPE QP QP MODEL
$ 470.68
Part #:SIEM5 Q1515NC

MINIATURE, THERMAL AND FIXED MAGNETIC TRIP, DUPLEX TYPE 1 INCH WIDTH X 2.06 INCH DEPTH X 3.12 INCH HEIGHT SIZE LOAD CENTER USED ON 14 TO 6 AWG (COPPER/ALUMINUM) WIRE SIZE UL 489 APPROVAL 120 VOLT AC VOLTAGE RATING PLUG-IN MOUNTING 10 KILOAMP INTERRUPTING RATING 15 AMP CURRENT RATING 1 POLE(S) LOAD LUG TERMINAL TYPE SPEEDFAX[TM] BRAND FRAME TYPE QT APPLICATION HEATING, AIR CONDITIONING, REFRIGERATION QT MODEL
$ 282.08
 