Heat Shrink, Flattened
Heat/moisture


Displaying: 1 - 16 of 16 Matching Items
16 Items
View:
Part #:PAND TV105-.50D20Y
HEAT/MOISTURE TYPE PVC MATERIAL BLACK COLOR 152.4 M UL, CSA APPROVAL 600 V VOLTAGE RATING 0.025 INCH THICKNESS -4 TO 221 DEG F TEMPERATURE RATING PANDUIT[R] BRAND NOMINAL SIZE 1/2 INCH INSIDED DIAMETER 0.524 INCH
$ 341.10
Qty:
add to cart
Part #:PAND H150X034H1T
HEAT SHRINK, FLATTENED TYPE POLYOLEFIN MATERIAL WHITE COLOR 0.34 INCH 0.06 INCH MIN. WIRE DIAMETER 0.19 INCH MAX. WIRE DIAMETER 18 TO 12 AWG WIRE SIZE 500 PER ROLL QUANTITY THERMAL TRANSFER PRINTER TYPE
$ 521.86
Qty:
add to cart
Part #:GE THQL2120
MOLDED CASE, FIXED THERMAL MAGNETIC, INTERNAL COMMON TRIP TYPE 2 INCH WIDTH X 2-3/8 INCH DEPTH X 3-9/32 INCH HEIGHT SIZE AL SERIES PANELBOARD USED ON 14 TO 8 AWG (COPPER), 12 TO 8 AWG (ALUMINUM) WIRE SIZE UL APPROVAL 120/240 VOLT AC VOLTAGE RATING 1 INCH PLUG-IN MOUNTING 10 KILOAMP INTERRUPTING RATING 20 AMP CURRENT RATING 2 POLE(S) COPPER/ALUMINUM LOAD LUG TERMINAL TYPE TRIP TYPE NON-INTERCHANGEABLE FRAME TYPE THQL TRIP FUNCTION LI APPLICATION HEATING, AIR CONDITIONING, REFRIGERATION THQL MODEL
$ 48.00
Qty:
add to cart
Part #:GE THQL2140
MOLDED CASE, FIXED THERMAL MAGNETIC, INTERNAL COMMON TRIP TYPE 2 INCH WIDTH X 2-3/8 INCH DEPTH X 3-9/32 INCH HEIGHT SIZE AL SERIES PANELBOARD USED ON 8 TO 3 AWG (COPPER/ALUMINUM) WIRE SIZE UL APPROVAL 120/240 VOLT AC VOLTAGE RATING 1 INCH PLUG-IN MOUNTING 10 KILOAMP INTERRUPTING RATING 40 AMP CURRENT RATING 2 POLE(S) COPPER/ALUMINUM LOAD LUG TERMINAL TYPE TRIP TYPE NON-INTERCHANGEABLE FRAME TYPE THQL TRIP FUNCTION LI APPLICATION HEATING, AIR CONDITIONING, REFRIGERATION THQL MODEL
$ 53.00
Qty:
add to cart
Part #:GE CR123C196A
CR124C SERIES OVERLOAD RELAY, CR1062R/CR1062S SERIES MANUAL STARTER, CR340/CR341 SERIES PUMPING PANEL USED ON PANEL MOUNTING 3 STANDARD PACKAGE 0, 1, M-0, M-1 NEMA SIZE 1.72 TO 1.91 AMPERE (1-PHASE 2 HEATER UNIT), 1.56 TO 1.73 AMPERE (3-PHASE 3 HEATER UNIT) MOTOR FLA CLASS 20, STANDARD TRIP TYPE
$ 9.00
Qty:
add to cart
Part #:GE THQB2115
MOLDED CASE, FIXED THERMAL MAGNETIC, INTERNAL COMMON TRIP TYPE 2 INCH W X 2-3/8 INCH D X 3-9/32 INCH H SIZE AQ SERIES PANELBOARD USED ON 14 TO 8 AWG (COPPER)/12 TO 8 AWG (ALUMINUM) WIRE SIZE UL APPROVAL 120/240 VAC VOLTAGE RATING 1 INCH BOLT-ON MOUNTING 10 KILOAMPERE INTERRUPTING RATING 15 AMPERE CURRENT RATING 2 POLE(S) COPPER/ALUMINUM LOAD LUG, BOLT-ON TERMINAL TYPE TRIP TYPE NON-INTERCHANGEABLE FRAME TYPE THQB TRIP FUNCTION LI APPLICATION HEATING, AIR CONDITIONING, REFRIGERATION SERIES THQB MODEL
$ 78.00
Qty:
add to cart
Part #:GE THQB2150
MOLDED CASE, FIXED THERMAL MAGNETIC, INTERNAL COMMON TRIP TYPE 2 INCH W X 2-3/8 INCH D X 3-9/32 INCH H SIZE AQ SERIES PANELBOARD USED ON 8 TO 3 AWG (COPPER/ALUMINUM) WIRE SIZE UL APPROVAL 120/240 VAC VOLTAGE RATING 1 INCH BOLT-ON MOUNTING 10 KILOAMPERE INTERRUPTING RATING 50 AMPERE CURRENT RATING 2 POLE(S) COPPER/ALUMINUM LOAD LUG, BOLT-ON TERMINAL TYPE TRIP TYPE NON-INTERCHANGEABLE FRAME TYPE THQB TRIP FUNCTION LI APPLICATION HEATING, AIR CONDITIONING, REFRIGERATION SERIES THQB MODEL
$ 78.00
Qty:
add to cart
Part #:GE THQP220
MOLDED CASE, FIXED THERMAL MAGNETIC, INTERNAL COMMON TRIP TYPE 1 INCH WIDTH X 2-3/8 INCH DEPTH X 3-9/32 INCH HEIGHT SIZE 14 TO 8 AWG (COPPER), 12 TO 8 AWG (ALUMINUM) WIRE SIZE UL APPROVAL 120/240 VOLT AC VOLTAGE RATING 1/2 INCH PLUG-IN MOUNTING 10 KILOAMP INTERRUPTING RATING 20 AMP CURRENT RATING 2 POLE(S) COPPER/ALUMINUM LOAD LUG TERMINAL TYPE TRIP TYPE NON-INTERCHANGEABLE FRAME TYPE THQP TRIP FUNCTION LI APPLICATION HEATING, AIR CONDITIONING, REFRIGERATION THQP MODEL
$ 48.00
Qty:
add to cart
Part #:GE CR123C250B
CR124C/CR124D SERIES OVERLOAD RELAY, CR1062R/CR1062S/CR1062T SERIES STARTER, CR340/CR341 SERIES PUMPING PANEL USED ON PANEL MOUNTING 3 STANDARD PACKAGE 0, 1, 2, M-0, M-1, M-1P NEMA SIZE 24 TO 27.8 AMPERE (1-PHASE 2 HEATER UNIT), 21.6 TO 24.7 AMPERE (3-PHASE 3 HEATER UNIT) MOTOR FLA CLASS 20, STANDARD TRIP TYPE CR123C MODEL
$ 9.00
Qty:
add to cart
Part #:GE CR123C326A
CR124C SERIES OVERLOAD RELAY, CR1062R/CR1062S SERIES MANUAL STARTER, CR340/CR341 SERIES PUMPING PANEL USED ON PANEL MOUNTING 3 STANDARD PACKAGE 0, 1, M-0, M-1 NEMA SIZE 2.77 TO 3.19 AMPERE (1-PHASE 2 HEATER UNIT), 2.48 TO 387 AMPERE (3-PHASE 3 HEATER UNIT) MOTOR FLA CLASS 20, STANDARD TRIP TYPE
$ 9.00
Qty:
add to cart
Part #:GE CR123C366B
CR124D/CR324D SERIES OVERLOAD RELAY, CR340/CR341 SERIES PUMPING PANEL USED ON PANEL MOUNTING 3 STANDARD PACKAGE 2, M-1P NEMA SIZE 35.4 TO 40.9 AMP (1-PHASE 2-HEATER UNIT), 32.6 TO 36.7 AMP (3-PHASE 3-HEATER UNIT) MOTOR FLA CLASS 20, STANDARD TRIP TYPE SPECTRA SERIES[TM] BRAND CR123C MODEL
$ 9.00
Qty:
add to cart
Part #:GE CR305X100A
BASIC AUXILIARY CONTACT TYPE 300 LINE MAGNETIC STARTER/CONTACTOR USED ON 1NO CONTACT CONFIGURATION 120 VAC/30 VDC 0.15 AMPERE CONTACT RATING 0, 1 NEMA SIZE LEFT/RIGHT MOUNTING LOCATION APPLICATION LOW VOLTAGE CONTROL CIRCUIT (24 V AND BELOW)
$ 36.00
Qty:
add to cart
Part #:GE CR123C356A
CR124C SERIES OVERLOAD RELAY, CR1062R/CR1062S SERIES MANUAL STARTER, CR340/CR341 SERIES PUMPING PANEL USED ON PANEL MOUNTING 3 STANDARD PACKAGE 0, 1, 6, 7, M-0, M-1 NEMA SIZE 3.20 TO 3.67 AMP (1-PHASE 2-HEATER UNIT), 2.8 TO 461 AMP (3-PHASE 3-HEATER UNIT) MOTOR FLA CLASS 20, STANDARD TRIP TYPE SPECTRA SERIES[TM] BRAND CR123C MODEL
$ 9.00
Qty:
add to cart
Part #:GE THQB2120
MOLDED CASE, FIXED THERMAL MAGNETIC, INTERNAL COMMON TRIP TYPE 2 INCH WIDTH X 2-3/8 INCH DEPTH X 3-9/32 INCH HEIGHT SIZE AQ SERIES PANELBOARD USED ON 14 TO 8 AWG (COPPER), 12 TO 8 AWG (ALUMINUM) WIRE SIZE UL APPROVAL 120/240 VOLT AC VOLTAGE RATING 1 INCH BOLT-ON MOUNTING 10 KILOAMP INTERRUPTING RATING 20 AMP CURRENT RATING 2 POLE(S) COPPER/ALUMINUM LOAD LUG TERMINAL TYPE TRIP TYPE NON-INTERCHANGEABLE FRAME TYPE THQB TRIP FUNCTION LI APPLICATION HEATING, AIR CONDITIONING, REFRIGERATION THQB MODEL
$ 78.00
Qty:
add to cart
Part #:GE THQB2160
MOLDED CASE, FIXED THERMAL MAGNETIC, INTERNAL COMMON TRIP TYPE 2 INCH WIDTH X 2-3/8 INCH DEPTH X 3-9/32 INCH HEIGHT SIZE AQ SERIES PANELBOARD USED ON 8 TO 3 AWG (COPPER/ALUMINUM) WIRE SIZE UL APPROVAL 120/240 VOLT AC VOLTAGE RATING 1 INCH BOLT-ON MOUNTING 10 KILOAMP INTERRUPTING RATING 60 AMP CURRENT RATING 2 POLE(S) COPPER/ALUMINUM LOAD LUG TERMINAL TYPE TRIP TYPE NON-INTERCHANGEABLE FRAME TYPE THQB TRIP FUNCTION LI APPLICATION HEATING, AIR CONDITIONING, REFRIGERATION THQB MODEL
$ 78.00
Qty:
add to cart
Part #:PAND H200X034H1T
HEAT SHRINK, FLATTENED TYPE POLYOLEFIN MATERIAL WHITE COLOR 0.34 INCH 0.06 INCH MIN. WIRE DIAMETER 0.19 INCH MAX. WIRE DIAMETER 18 TO 12 AWG WIRE SIZE 500 PER ROLL QUANTITY THERMAL TRANSFER PRINTER TYPE
$ 574.46
Qty:
add to cart
 
Displaying: 1 - 16 of 16 Matching Items