Iec Contactors
General Purpose Plug-in Relays & Accessories


Displaying: 1 - 20 of 20 Matching Items
20 Items
View:
Part #:GE CL00A310TJ

NON-REVERSING TYPE UL 508, UL (CANADA AND US), CSA C22.2, CE, SETI, RINA APPROVAL 35 MM DIN RAIL/SCREW FRONT/SIDE MOUNT MOUNTING NEMA 1 ENCLOSURE 9 AMPERE AT 440 V 50/60 HZ (AC-3), 25 AMPERE (AC-1) CURRENT RATING 3 POLE(S) IEC, NEMA CONSTRUCTION STANDARD 110 VAC AT 50 HZ, 125 VAC AT 60 HZ COIL VOLTAGE 1NO AUXILIARY CONTACT 3 HP AT 220/230 V, 5.5 HP AT 380/400/415/440 V, 7.5 HP AT 500 V, 2.2 KW AT 220/230 V, 4 KW AT 380/400/415/440 V, 5.5 KW AT 500 V POWER RATING/VOLTAGE APPLICABLE STANDARD IEC/EN 60947-1, IEC/EN 60947-4-1, IEC/EN 60947-5-1, EN 50005, VDE 0660, VDE 102 OPERATING TEMPERATURE -13 TO 131 DEG F MAXIMUM AUXILIARY CONTACTS 4 DEGREE OF PROTECTION IP20/IP10 CL MODEL
$ 91.00
Part #:GE CL01A310TJ

NON-REVERSING TYPE UL 508, UL (CANADA AND US), CSA C22.2, CE, SETI, RINA APPROVAL 35 MM DIN RAIL/SCREW FRONT/SIDE MOUNT MOUNTING NEMA 1 ENCLOSURE 12 AMPERE AT 440 V 50/60 HZ (AC-3), 25 AMPERE (AC-1) CURRENT RATING 3 POLE(S) IEC, NEMA CONSTRUCTION STANDARD 110 VAC AT 50 HZ COIL VOLTAGE 1NO AUXILIARY CONTACT 4 HP AT 220/230 V, 7.5 HP AT 380/400/415/440 V, 10 HP AT 500 V, 3 KW AT 220/230 V, 5.5 KW AT 380/400/415/440 V, 7.5 KW AT 500 V POWER RATING/VOLTAGE APPLICABLE STANDARD IEC/EN 60947-1, IEC/EN 60947-4-1, IEC/EN 60947-5-1, EN 50005, VDE 0660, VDE 102 OPERATING TEMPERATURE -13 TO 131 DEG F MAXIMUM AUXILIARY CONTACTS 4 DEGREE OF PROTECTION IP20/IP10 CL MODEL
$ 109.00
Part #:GE CL02A310TJ

NON-REVERSING TYPE UL 508, UL (CANADA AND US), CSA C22.2, CE, SETI, RINA APPROVAL 35 MM DIN RAIL/SCREW FRONT/SIDE MOUNT MOUNTING NEMA 1 ENCLOSURE 18 AMPERE AT 440 V 50/60 HZ (AC-3), 32 AMPERE (AC-1) CURRENT RATING 3 POLE(S) IEC, NEMA CONSTRUCTION STANDARD 110 VAC AT 50 HZ, 125 VAC AT 60 HZ COIL VOLTAGE 1NO AUXILIARY CONTACT 5.5 HP AT 220/230 V, 10 HP AT 380/400/415/440 V, 13.5 HP AT 500 V, 4 KW AT 220/230 V, 7.5 KW AT 380/400/415/440 V, 10 KW AT 500 V POWER RATING/VOLTAGE APPLICABLE STANDARD IEC/EN 60947-1, IEC/EN 60947-4-1, IEC/EN 60947-5-1, EN 50005, VDE 0660, VDE 102 OPERATING TEMPERATURE -13 TO 131 DEG F MAXIMUM AUXILIARY CONTACTS 4 DEGREE OF PROTECTION IP20/IP10 CL MODEL
$ 124.00
Part #:GE CL00D310TD

NON-REVERSING TYPE UL 508, UL (CANADA AND US), CSA C22.2, CE, SETI, RINA APPROVAL 35 MM DIN RAIL/SCREW FRONT/SIDE MOUNT MOUNTING NEMA 1 ENCLOSURE 9 AMPERE AT 440 V 50/60 HZ (AC-3), 25 AMPERE (AC-1) CURRENT RATING 3 POLE(S) IEC, NEMA CONSTRUCTION STANDARD 24 VDC COIL VOLTAGE 1NO AUXILIARY CONTACT 3 HP AT 220/230 V, 5.5 HP AT 380/400/415/440 V, 7.5 HP AT 500 V, 2.2 KW AT 220/230 V, 4 KW AT 380/400/415/440 V, 5.5 KW AT 500 V POWER RATING/VOLTAGE APPLICABLE STANDARD IEC/EN 60947-1, IEC/EN 60947-4-1, IEC/EN 60947-5-1, EN 50005, VDE 0660, VDE 102 OPERATING TEMPERATURE -13 TO 131 DEG F MAXIMUM AUXILIARY CONTACTS 4 DEGREE OF PROTECTION IP20/IP10 CL MODEL
$ 109.00
Part #:GE CL01D310TD

NON-REVERSING TYPE UL 508, UL (CANADA AND US), CSA C22.2, CE, SETI, RINA APPROVAL 35 MM DIN RAIL/SCREW FRONT/SIDE MOUNT MOUNTING NEMA 1 ENCLOSURE 12 AMPERE AT 440 V 50/60 HZ (AC-3), 25 AMPERE (AC-1) CURRENT RATING 3 POLE(S) IEC, NEMA CONSTRUCTION STANDARD 24 VDC COIL VOLTAGE 1NO AUXILIARY CONTACT 4 HP AT 220/230 V, 7.5 HP AT 380/400/415/440 V, 10 HP AT 500 V, 3 KW AT 220/230 V, 5.5 KW AT 380/400/415/440 V, 7.5 KW AT 500 V POWER RATING/VOLTAGE APPLICABLE STANDARD IEC/EN 60947-1, IEC/EN 60947-4-1, IEC/EN 60947-5-1, EN 50005, VDE 0660, VDE 102 OPERATING TEMPERATURE -13 TO 131 DEG F MAXIMUM AUXILIARY CONTACTS 4 DEGREE OF PROTECTION IP20/IP10 CL MODEL
$ 133.00
Part #:GE CL02D310TD

NON-REVERSING TYPE UL 508, UL (CANADA AND US), CSA C22.2, CE, SETI, RINA APPROVAL 35 MM DIN RAIL/SCREW FRONT/SIDE MOUNT MOUNTING NEMA 1 ENCLOSURE 18 AMPERE AT 440 V 50/60 HZ (AC-3), 32 AMPERE (AC-1) CURRENT RATING 3 POLE(S) IEC, NEMA CONSTRUCTION STANDARD 24 VDC COIL VOLTAGE 1NO AUXILIARY CONTACT 5.5 HP AT 220/230 V, 10 HP AT 380/400/415/440 V, 13.5 HP AT 500 V, 4 KW AT 220/230 V, 7.5 KW AT 380/400/415/440 V, 10 KW AT 500 V POWER RATING/VOLTAGE APPLICABLE STANDARD IEC/EN 60947-1, IEC/EN 60947-4-1, IEC/EN 60947-5-1, EN 50005, VDE 0660, VDE 102 OPERATING TEMPERATURE -13 TO 131 DEG F MAXIMUM AUXILIARY CONTACTS 4 DEGREE OF PROTECTION IP20/IP10
$ 147.00
Part #:GE CL25A310TJ

NON-REVERSING TYPE UL 508, CSA C22.2, CE APPROVAL 35 MM DIN RAIL/SCREW FRONT MOUNT MOUNTING 32 AMPERE (UL CONTINUOUS), 45 AMPERE (IEC AC-1) CURRENT RATING 3 POLE(S) IEC CONSTRUCTION STANDARD 110 VAC AT 50 HZ, 120 VAC AT 60 HZ COIL VOLTAGE 1NO AUXILIARY CONTACT 1.5 HP AT 115 V 60 HZ, 3 HP AT 230 V 60 HZ 1-PHASE, 5 HP AT 200 V 60 HZ, 7.5 HP AT 230 V 60 HZ, 15 HP AT 460/575 V 60 HZ 3-PHASE, 11 KW AT 380/415 V 50 HZ POWER RATING/VOLTAGE APPLICABLE STANDARD IEC 947-1, IEC 947-4, EN 50005, VDE 0660, VDE 102 OPERATING TEMPERATURE -13 TO 131 DEG F MAXIMUM AUXILIARY CONTACTS 4 APPLICATION MOTOR LOAD AND DUTY CYCLE CL MODEL
$ 138.00
Part #:GE CL02D310RD

NON REVERSING TYPE UL 508, UL (CANADA AND US), CSA C22.2, CE, SETI, RINA APPROVAL 35 MM DIN RAIL/SCREW MOUNTING 18 AMPERE AT 440 V 50/60 HZ (AC-3), 32 AMPERE (AC-1) CURRENT RATING 3 POLE(S) IEC CONSTRUCTION STANDARD 24 VDC COIL VOLTAGE 1NO FRONT/SIDE MOUNTED AUXILIARY CONTACT 5.5 HP AT 220/230 V, 10 HP AT 380/400/415/440 V, 13.5 HP AT 500 V, 4 KW AT 220/230 V, 7.5 KW AT 380/400/415/440 V, 10 KW AT 500 V POWER RATING/VOLTAGE C-2000[T] BRAND APPLICABLE STANDARD IEC/EN 60947-1, IEC/EN 60947-4-1, IEC/EN 60947-5-1, EN 50005, VDE 0660, VDE 102 WITH RING TERMINAL CL MODEL
$ 155.00
Part #:CARLON E958F

PVC MATERIAL 40 SCHEDULE UL APPROVAL 75 PER CARTON STANDARD PACKAGE 1 INCH TRADE SIZE E958 MODEL
$ 10.72
C
Part #:CARLON E958G

PVC MATERIAL 40 SCHEDULE UL APPROVAL 40 PER CARTON STANDARD PACKAGE 1-1/4 INCH TRADE SIZE E958 MODEL
$ 4.07
C
Part #:CARLON E950FE

BELL TO SPIGOT BUSHING TYPE PVC MATERIAL 3/4 INCH SMALL END TRADE SIZE 1 INCH LARGE END TRADE SIZE UL, CSA APPROVAL 100 STANDARD PACKAGE SCHEDULE 40
$ 14.54
C
Part #:CARLON E950GF

BELL TO SPIGOT BUSHING TYPE PVC MATERIAL 1 INCH SMALL END TRADE SIZE 1-1/4 INCH LARGE END TRADE SIZE UL, CSA APPROVAL 50 STANDARD PACKAGE SCHEDULE 40
$ 18.86
C
Part #:CARLON E958J

PVC MATERIAL 40 SCHEDULE UL APPROVAL 25 PER CARTON STANDARD PACKAGE 2 INCH TRADE SIZE E958 MODEL
$ 22.61
C
Part #:CARLON E950ED

BELL TO SPIGOT BUSHING TYPE PVC MATERIAL 1/2 INCH SMALL END TRADE SIZE 3/4 INCH LARGE END TRADE SIZE UL, CSA APPROVAL 100 STANDARD PACKAGE SCHEDULE 40
$ 6.17
C
Part #:GE CR420KA3

CR420K SERIES GENERAL PURPOSE PLUG-IN RELAY USED ON 10 AMPERE AT 250 VAC/24 VDC, 7A AT 250 VAC, 1/2 HP AT 240 VAC, 1/3 HP AT 120 VAC CONTACT RATING UL, CSA, CE APPROVAL DIN RAIL/PANEL MOUNTING 3 POLE(S) CARRY CURRENT 10 AMPERE MAXIMUM CONTACT VOLTAGE 220 VAC, 110 VDC CONTACT CONFIGURATION 3PDT CR420K MODEL
$ 8.00
Part #:GE CL45A310MJ

NON-REVERSING TYPE UL 508, CSA C22.2, CE APPROVAL 35 MM DIN RAIL/SCREW FRONT MOUNT MOUNTING 55 AMPERE (UL CONTINUOUS), 60 AMPERE (IEC AC-1) CURRENT RATING 3 POLE(S) IEC CONSTRUCTION STANDARD 110 VAC AT 50 HZ, 120 VAC AT 60 HZ COIL VOLTAGE 1NO AUXILIARY CONTACT 3 HP AT 115 V 60 HZ, 5 HP AT 230 V 60 HZ 1-PHASE, 10 HP AT 200/230 V 60 HZ, 25 HP AT 460/575 V 60 HZ 3-PHASE, 18.5 KW AT 380/415 V 50 HZ POWER RATING/VOLTAGE APPLICABLE STANDARD IEC 947-1, IEC 947-4, EN 50005, VDE 0660, VDE 102 OPERATING TEMPERATURE -13 TO 131 DEG F MAXIMUM AUXILIARY CONTACTS 6 APPLICATION MOTOR LOAD AND DUTY CYCLE CL MODEL
$ 173.00
Part #:GE CR420MPC044J

AC OPERATED TYPE 4PDT CONTACT CONFIGURATION UL, CSA, CE APPROVAL SOCKET MOUNTING 120 VAC COIL VOLTAGE 5 AMPERE CONTACT CURRENT RATING 240 VAC, 28 VDC CONTACT VOLTAGE RATING APPLICATION INDUSTRIAL EQUIPMENT, MACHINE TOOL, HVAC, LIGHTING, VENDING, COMMERCIAL APPLIANCE, ELEVATOR AND SPA CONTROL WITH PUSH TO TEST, LED INDICATOR OPERATING TEMPERATURE -25 TO 70 DEG C 420M MODEL
$ 14.00
Part #:GE CR420NA2

CR420N SERIES GENERAL PURPOSE PLUG-IN RELAY USED ON 10 AMPERE AT 240 VAC/24 VDC (RESISTIVE), 5 AMPERE AT 240 VAC/24 VDC (INDUCTIVE), 1/2 HP AT 240 VAC, 1/3 HP AT 120 VAC CONTACT RATING UL, CSA, CE APPROVAL DIN RAIL/PANEL MOUNTING 2 POLE(S) CARRY CURRENT 10 AMPERE MAXIMUM CONTACT VOLTAGE 240 VAC, 110 VDC CONTACT CONFIGURATION DPDT CR420N MODEL
$ 7.00
Part #:GE CR420KA2

CR420K SERIES GENERAL PURPOSE PLUG-IN RELAY USED ON 10 AMPERE AT 250 VAC/24 VDC, 7 AMPERE AT 250 VAC, 1/2 HP AT 240 VAC, 1/3 HP AT 120 VAC CONTACT RATING UL, CSA, CE APPROVAL DIN RAIL/PANEL MOUNTING 2 POLE(S) CARRY CURRENT RATING 10 AMPERE MAXIMUM CONTACT VOLTAGE RATING 220 VAC, 110 VDC CONTACT CONFIGURATION DPDT MODEL CR420K MODEL
$ 5.00
Part #:GE CL25D310TD

FULL VOLTAGE, NON REVERSING TYPE UL 508, CSA C22.2, CE APPROVAL 35 MM DIN RAIL/SCREW MOUNTING 32 AMPERE (UL CONTINUOUS), 45 AMPERE (IEC AC-1) CURRENT RATING 3 POLE(S) IEC CONSTRUCTION STANDARD 24 VDC COIL VOLTAGE 1NO FRONT MOUNTED AUXILIARY CONTACT 1.5 HP AT 115 V 60 HZ, 3 HP AT 230 V 60 HZ 1 PHASE 5 HP AT 200 V 60 HZ, 7.5 HP AT 230 V 60 HZ, 15 HP AT 460/575 V 60 HZ 3 PHASE 11 KW AT 380/415 V 50 HZ POWER RATING/VOLTAGE C-2000[T] BRAND APPLICABLE STANDARD IEC 947-1, IEC 947-4, EN 50005, VDE 0660, VDE 102 OPERATING TEMPERATURE -13 TO 131 DEG F MAXIMUM AUXILIARY CONTACTS 4 CL MODEL
$ 166.00
 
Displaying: 1 - 20 of 20 Matching Items