General Purpose Plug-in Relays & Accessories
Current Limiting Fuses
View:
Active Filters :
Part #:ARL FA101
- ADJUSTABLE TYPE NON METALLIC MATERIAL 3.72 INCH 3.72 WIDTH IN INCH 2.299 INCH 2.299 HEIGHT IN INCH 3.875 INCH 3.875 DEPTH IN INCH 1 GANG(S) UL APPROVAL WOOD/STEEL STUD MOUNTING 25 STANDARD PACKAGE 21 CU INCH CAPACITY
$
4.08
Qty:
Part #:ARL FA102
- ADJUSTABLE TYPE NON METALLIC MATERIAL 3.72 INCH 3.72 WIDTH IN INCH 4.111 INCH 4.111 HEIGHT IN INCH 3.875 INCH 3.875 DEPTH IN INCH 2 GANG(S) UL APPROVAL WOOD/STEEL STUD MOUNTING 10 STANDARD PACKAGE 43.5 CU INCH CAPACITY
$
5.25
Qty:
Part #:ARL CE1RP
- CABLE ENTRY BRACKET AND SLOTTED COVER TYPE LOW VOLTAGE CABLE MANAGEMENT ENCLOSURE USED ON
$
6.83
Qty:
Part #:CARLON B618R-UPC
- OLD WORK TYPE BLUE POLYCARBONATE MATERIAL 2-5/8 INCH UL APPROVAL 4-1/4 INCH DIAMETER 100 PER CARTON STANDARD PACKAGE 18 CU INCH CAPACITY (4) INTEGRAL CLAMP CABLE ENTRY ZIP BOX. BRAND
$
6.94
Qty:
Part #:CARLON B108B-UPC
- SHALLOW TYPE PVC MATERIAL 2-3/8 INCH 3-5/8 INCH 1-1/4 INCH 1 GANG(S) UL APPROVAL BRACKET MOUNTING 25 STANDARD PACKAGE 8 CU INCH CAPACITY BLUE[T], ZIP BOX. BRAND COLOR BLUE
Part #:BUSS LP-CC-1-6/10
- CLASS CC REJECTION TYPE 1-1/2 INCH UL 248-4, CSA, CE APPROVAL 600 VAC/300 VDC VOLTAGE RATING 13/32 INCH DIAMETER 200000 AMPERE (SYMMETRICAL), 20000 AMPERE (DC) INTERRUPTING RATING 1-6/10 AMPERE CURRENT RATING FERRULE TERMINAL TYPE TIME DELAY CHARACTERISTICS LOW-PEAK. BRAND CURRENT LIMITING MELAMINE TUBE LP-CC MODEL
$
84.60
Qty:
Part #:GE CR420KA3
- CR420K SERIES GENERAL PURPOSE PLUG-IN RELAY USED ON 10 AMPERE AT 250 VAC/24 VDC, 7A AT 250 VAC, 1/2 HP AT 240 VAC, 1/3 HP AT 120 VAC CONTACT RATING UL, CSA, CE APPROVAL DIN RAIL/PANEL MOUNTING 3 POLE(S) CARRY CURRENT 10 AMPERE MAXIMUM CONTACT VOLTAGE 220 VAC, 110 VDC CONTACT CONFIGURATION 3PDT CR420K MODEL
$
8.00
Qty:
Part #:BUSS LP-CC-1
- CLASS CC REJECTION TYPE 1-1/2 INCH UL 248-4, CSA, CE APPROVAL 600 VAC/300 VDC VOLTAGE RATING 13/32 INCH DIAMETER 200 KILOAMPERE (SYMMETRICAL), 20 KILOAMPERE (DC) INTERRUPTING RATING 1 AMPERE CURRENT RATING FERRULE TERMINAL TYPE TIME DELAY CHARACTERISTICS LOW-PEAK[TM] BRAND APPLICATION SUPERIOR PROTECTION FOR SMALL HORSEPOWER MOTOR CIRCUIT SERIES LP-CC MODEL
$
81.22
Qty:
Part #:BUSS LP-CC-10
- CLASS CC REJECTION TYPE 1-1/2 INCH UL 248-4, CSA, CE APPROVAL 600 VOLT AC, 150 VOLT DC VOLTAGE RATING 13/32 INCH DIAMETER 200 KILOAMP SYMMETRICAL (AC), 20 KILOAMP (DC) INTERRUPTING RATING 10 AMP CURRENT RATING FERRULE TERMINAL TYPE TIME DELAY CHARACTERISTICS LOW-PEAK[TM] BRAND ROHS COMPLIANT MATERIAL MELAMINE (TUBE) APPLICATION BRANCH CIRCUIT PROTECTION, SPECIALIZED CIRCUIT, INDUSTRIAL CONTROL AND PANEL, ISOLATED IN-LINE FUSE HOLDER LP-CC MODEL
$
81.22
Qty:
Part #:GE CR123C356A
- CR124C SERIES OVERLOAD RELAY, CR1062R/CR1062S SERIES MANUAL STARTER, CR340/CR341 SERIES PUMPING PANEL USED ON PANEL MOUNTING 3 STANDARD PACKAGE 0, 1, 6, 7, M-0, M-1 NEMA SIZE 3.20 TO 3.67 AMP (1-PHASE 2-HEATER UNIT), 2.8 TO 461 AMP (3-PHASE 3-HEATER UNIT) MOTOR FLA CLASS 20, STANDARD TRIP TYPE SPECTRA SERIES[TM] BRAND CR123C MODEL
$
9.00
Qty:
Part #:BUSS LP-CC-15
- CLASS CC REJECTION TYPE 1-1/2 INCH UL 248-4, CSA, CE APPROVAL 600 VAC/150 VDC VOLTAGE RATING 13/32 INCH DIAMETER 200 KILOAMPERE (SYMMETRICAL), 20 KILOAMPERE (DC) INTERRUPTING RATING 15 AMPERE CURRENT RATING FERRULE TERMINAL TYPE TIME DELAY CHARACTERISTICS LOW-PEAK[TM] BRAND APPLICATION SUPERIOR PROTECTION FOR SMALL HORSEPOWER MOTOR CIRCUIT SERIES LP-CC MODEL
$
81.22
Qty:
Part #:BUSS LP-CC-2
- CLASS CC REJECTION TYPE 1-1/2 INCH UL 248-4, CSA, CE APPROVAL 600 VOLT AC, 300 VOLT DC VOLTAGE RATING 13/32 INCH DIAMETER 200 KILOAMP SYMMETRICAL (AC), 20 KILOAMP (DC) INTERRUPTING RATING 2 AMP CURRENT RATING FERRULE TERMINAL TYPE TIME DELAY CHARACTERISTICS LOW-PEAK[TM] BRAND ROHS COMPLIANT MATERIAL MELAMINE (TUBE) APPLICATION BRANCH CIRCUIT PROTECTION, SPECIALIZED CIRCUIT, INDUSTRIAL CONTROL AND PANEL, ISOLATED IN-LINE FUSE HOLDER LP-CC MODEL
$
81.22
Qty:
Part #:BUSS LP-CC-20
- CLASS CC REJECTION TYPE 1-1/2 INCH UL 248-4, CSA, CE APPROVAL 600 VOLT AC, 300 VOLT DC VOLTAGE RATING 13/32 INCH DIAMETER 200 KILOAMP SYMMETRICAL (AC), 20 KILOAMP (DC) INTERRUPTING RATING 20 AMP CURRENT RATING FERRULE TERMINAL TYPE TIME DELAY CHARACTERISTICS LOW-PEAK[TM] BRAND ROHS COMPLIANT MATERIAL MELAMINE (TUBE) APPLICATION BRANCH CIRCUIT PROTECTION, SPECIALIZED CIRCUIT, INDUSTRIAL CONTROL AND PANEL, ISOLATED IN-LINE FUSE HOLDER LP-CC MODEL
$
81.22
Qty:
Part #:BUSS LP-CC-3
- CLASS CC REJECTION TYPE 1-1/2 INCH UL 248-4, CSA, CE APPROVAL 600 VAC/150 VDC VOLTAGE RATING 13/32 INCH DIAMETER 200 KILOAMPERE (SYMMETRICAL), 20 KILOAMPERE (DC) INTERRUPTING RATING 3 AMPERE CURRENT RATING FERRULE TERMINAL TYPE TIME DELAY CHARACTERISTICS LOW-PEAK[TM] BRAND APPLICATION SUPERIOR PROTECTION FOR SMALL HORSEPOWER MOTOR CIRCUIT SERIES LP-CC MODEL
$
81.22
Qty:
Part #:BUSS LP-CC-30
- CLASS CC REJECTION TYPE 1-1/2 INCH UL 248-4, CSA, CE APPROVAL 600 VOLT AC, 300 VOLT DC VOLTAGE RATING 13/32 INCH DIAMETER 200 KILOAMP SYMMETRICAL (AC), 20 KILOAMP (DC) INTERRUPTING RATING 30 AMP CURRENT RATING FERRULE TERMINAL TYPE TIME DELAY CHARACTERISTICS LOW-PEAK[TM] BRAND ROHS COMPLIANT MATERIAL MELAMINE (TUBE) APPLICATION BRANCH CIRCUIT PROTECTION, SPECIALIZED CIRCUIT, INDUSTRIAL CONTROL AND PANEL, ISOLATED IN-LINE FUSE HOLDER LP-CC MODEL
$
81.22
Qty:
closeout
Part #:GE CR123C196A
- CLOSEOUTS Only 4 Left!
- CR124C SERIES OVERLOAD RELAY, CR1062R/CR1062S SERIES MANUAL STARTER, CR340/CR341 SERIES PUMPING PANEL USED ON PANEL MOUNTING 3 STANDARD PACKAGE 0, 1, M-0, M-1 NEMA SIZE 1.72 TO 1.91 AMPERE (1-PHASE 2 HEATER UNIT), 1.56 TO 1.73 AMPERE (3-PHASE 3 HEATER UNIT) MOTOR FLA CLASS 20, STANDARD TRIP TYPE
$
9.00
Qty:
Part #:BUSS LP-CC-5
- CLASS CC REJECTION TYPE 1-1/2 INCH UL 248-4, CSA, CE APPROVAL 600 VOLT AC, 150 VOLT DC VOLTAGE RATING 13/32 INCH DIAMETER 200 KILOAMP SYMMETRICAL (AC), 20 KILOAMP (DC) INTERRUPTING RATING 5 AMP CURRENT RATING FERRULE TERMINAL TYPE TIME DELAY CHARACTERISTICS LOW-PEAK[TM] BRAND ROHS COMPLIANT MATERIAL MELAMINE (TUBE) APPLICATION BRANCH CIRCUIT PROTECTION, SPECIALIZED CIRCUIT, INDUSTRIAL CONTROL AND PANEL, ISOLATED IN-LINE FUSE HOLDER LP-CC MODEL
$
81.22
Qty:
Part #:BUSS LP-CC-6
- CLASS CC REJECTION TYPE 1-1/2 INCH UL 248-4, CSA, CE APPROVAL 600 VAC/150 VDC VOLTAGE RATING 13/32 INCH DIAMETER 200 KILOAMPERE (SYMMETRICAL), 20 KILOAMPERE (DC) INTERRUPTING RATING 6 AMPERE CURRENT RATING FERRULE TERMINAL TYPE TIME DELAY CHARACTERISTICS LOW-PEAK[TM] BRAND APPLICATION SUPERIOR PROTECTION FOR SMALL HORSEPOWER MOTOR CIRCUIT SERIES LP-CC MODEL
$
81.22
Qty:
closeout
Part #:GE CR123C250B
- CLOSEOUTS Only 3 Left!
- CR124C/CR124D SERIES OVERLOAD RELAY, CR1062R/CR1062S/CR1062T SERIES STARTER, CR340/CR341 SERIES PUMPING PANEL USED ON PANEL MOUNTING 3 STANDARD PACKAGE 0, 1, 2, M-0, M-1, M-1P NEMA SIZE 24 TO 27.8 AMPERE (1-PHASE 2 HEATER UNIT), 21.6 TO 24.7 AMPERE (3-PHASE 3 HEATER UNIT) MOTOR FLA CLASS 20, STANDARD TRIP TYPE CR123C MODEL
$
9.00
Qty:
Part #:GE CR123C326A
- CR124C SERIES OVERLOAD RELAY, CR1062R/CR1062S SERIES MANUAL STARTER, CR340/CR341 SERIES PUMPING PANEL USED ON PANEL MOUNTING 3 STANDARD PACKAGE 0, 1, M-0, M-1 NEMA SIZE 2.77 TO 3.19 AMPERE (1-PHASE 2 HEATER UNIT), 2.48 TO 387 AMPERE (3-PHASE 3 HEATER UNIT) MOTOR FLA CLASS 20, STANDARD TRIP TYPE
$
9.00
Qty:
closeout
Part #:GE CR123C366B
- CLOSEOUTS Only 3 Left!
- CR124D/CR324D SERIES OVERLOAD RELAY, CR340/CR341 SERIES PUMPING PANEL USED ON PANEL MOUNTING 3 STANDARD PACKAGE 2, M-1P NEMA SIZE 35.4 TO 40.9 AMP (1-PHASE 2-HEATER UNIT), 32.6 TO 36.7 AMP (3-PHASE 3-HEATER UNIT) MOTOR FLA CLASS 20, STANDARD TRIP TYPE SPECTRA SERIES[TM] BRAND CR123C MODEL
$
9.00
Qty:
Part #:GE CR420MPC044J
- AC OPERATED TYPE 4PDT CONTACT CONFIGURATION UL, CSA, CE APPROVAL SOCKET MOUNTING 120 VAC COIL VOLTAGE 5 AMPERE CONTACT CURRENT RATING 240 VAC, 28 VDC CONTACT VOLTAGE RATING APPLICATION INDUSTRIAL EQUIPMENT, MACHINE TOOL, HVAC, LIGHTING, VENDING, COMMERCIAL APPLIANCE, ELEVATOR AND SPA CONTROL WITH PUSH TO TEST, LED INDICATOR OPERATING TEMPERATURE -25 TO 70 DEG C 420M MODEL
$
14.00
Qty:
Part #:GE CR420NA2
- CR420N SERIES GENERAL PURPOSE PLUG-IN RELAY USED ON 10 AMPERE AT 240 VAC/24 VDC (RESISTIVE), 5 AMPERE AT 240 VAC/24 VDC (INDUCTIVE), 1/2 HP AT 240 VAC, 1/3 HP AT 120 VAC CONTACT RATING UL, CSA, CE APPROVAL DIN RAIL/PANEL MOUNTING 2 POLE(S) CARRY CURRENT 10 AMPERE MAXIMUM CONTACT VOLTAGE 240 VAC, 110 VDC CONTACT CONFIGURATION DPDT CR420N MODEL
$
7.00
Qty:
Part #:GE CR420KA2
- CR420K SERIES GENERAL PURPOSE PLUG-IN RELAY USED ON 10 AMPERE AT 250 VAC/24 VDC, 7 AMPERE AT 250 VAC, 1/2 HP AT 240 VAC, 1/3 HP AT 120 VAC CONTACT RATING UL, CSA, CE APPROVAL DIN RAIL/PANEL MOUNTING 2 POLE(S) CARRY CURRENT RATING 10 AMPERE MAXIMUM CONTACT VOLTAGE RATING 220 VAC, 110 VDC CONTACT CONFIGURATION DPDT MODEL CR420K MODEL
$
5.00
Qty:
Displaying: 1 - 24 of 26 Matching Items