Full Voltage, Non Reversing
Angled, Polarized


Displaying: 1 - 17 of 17 Matching Items
17 Items
View:
Part #:GE CL00A310TJ

NON-REVERSING TYPE UL 508, UL (CANADA AND US), CSA C22.2, CE, SETI, RINA APPROVAL 35 MM DIN RAIL/SCREW FRONT/SIDE MOUNT MOUNTING NEMA 1 ENCLOSURE 9 AMPERE AT 440 V 50/60 HZ (AC-3), 25 AMPERE (AC-1) CURRENT RATING 3 POLE(S) IEC, NEMA CONSTRUCTION STANDARD 110 VAC AT 50 HZ, 125 VAC AT 60 HZ COIL VOLTAGE 1NO AUXILIARY CONTACT 3 HP AT 220/230 V, 5.5 HP AT 380/400/415/440 V, 7.5 HP AT 500 V, 2.2 KW AT 220/230 V, 4 KW AT 380/400/415/440 V, 5.5 KW AT 500 V POWER RATING/VOLTAGE APPLICABLE STANDARD IEC/EN 60947-1, IEC/EN 60947-4-1, IEC/EN 60947-5-1, EN 50005, VDE 0660, VDE 102 OPERATING TEMPERATURE -13 TO 131 DEG F MAXIMUM AUXILIARY CONTACTS 4 DEGREE OF PROTECTION IP20/IP10 CL MODEL
$ 91.00
Part #:GE CL01A310TJ

NON-REVERSING TYPE UL 508, UL (CANADA AND US), CSA C22.2, CE, SETI, RINA APPROVAL 35 MM DIN RAIL/SCREW FRONT/SIDE MOUNT MOUNTING NEMA 1 ENCLOSURE 12 AMPERE AT 440 V 50/60 HZ (AC-3), 25 AMPERE (AC-1) CURRENT RATING 3 POLE(S) IEC, NEMA CONSTRUCTION STANDARD 110 VAC AT 50 HZ COIL VOLTAGE 1NO AUXILIARY CONTACT 4 HP AT 220/230 V, 7.5 HP AT 380/400/415/440 V, 10 HP AT 500 V, 3 KW AT 220/230 V, 5.5 KW AT 380/400/415/440 V, 7.5 KW AT 500 V POWER RATING/VOLTAGE APPLICABLE STANDARD IEC/EN 60947-1, IEC/EN 60947-4-1, IEC/EN 60947-5-1, EN 50005, VDE 0660, VDE 102 OPERATING TEMPERATURE -13 TO 131 DEG F MAXIMUM AUXILIARY CONTACTS 4 DEGREE OF PROTECTION IP20/IP10 CL MODEL
$ 109.00
Part #:GE CL02A310TJ

NON-REVERSING TYPE UL 508, UL (CANADA AND US), CSA C22.2, CE, SETI, RINA APPROVAL 35 MM DIN RAIL/SCREW FRONT/SIDE MOUNT MOUNTING NEMA 1 ENCLOSURE 18 AMPERE AT 440 V 50/60 HZ (AC-3), 32 AMPERE (AC-1) CURRENT RATING 3 POLE(S) IEC, NEMA CONSTRUCTION STANDARD 110 VAC AT 50 HZ, 125 VAC AT 60 HZ COIL VOLTAGE 1NO AUXILIARY CONTACT 5.5 HP AT 220/230 V, 10 HP AT 380/400/415/440 V, 13.5 HP AT 500 V, 4 KW AT 220/230 V, 7.5 KW AT 380/400/415/440 V, 10 KW AT 500 V POWER RATING/VOLTAGE APPLICABLE STANDARD IEC/EN 60947-1, IEC/EN 60947-4-1, IEC/EN 60947-5-1, EN 50005, VDE 0660, VDE 102 OPERATING TEMPERATURE -13 TO 131 DEG F MAXIMUM AUXILIARY CONTACTS 4 DEGREE OF PROTECTION IP20/IP10 CL MODEL
$ 124.00
Part #:GE CL00D310TD

NON-REVERSING TYPE UL 508, UL (CANADA AND US), CSA C22.2, CE, SETI, RINA APPROVAL 35 MM DIN RAIL/SCREW FRONT/SIDE MOUNT MOUNTING NEMA 1 ENCLOSURE 9 AMPERE AT 440 V 50/60 HZ (AC-3), 25 AMPERE (AC-1) CURRENT RATING 3 POLE(S) IEC, NEMA CONSTRUCTION STANDARD 24 VDC COIL VOLTAGE 1NO AUXILIARY CONTACT 3 HP AT 220/230 V, 5.5 HP AT 380/400/415/440 V, 7.5 HP AT 500 V, 2.2 KW AT 220/230 V, 4 KW AT 380/400/415/440 V, 5.5 KW AT 500 V POWER RATING/VOLTAGE APPLICABLE STANDARD IEC/EN 60947-1, IEC/EN 60947-4-1, IEC/EN 60947-5-1, EN 50005, VDE 0660, VDE 102 OPERATING TEMPERATURE -13 TO 131 DEG F MAXIMUM AUXILIARY CONTACTS 4 DEGREE OF PROTECTION IP20/IP10 CL MODEL
$ 109.00
Part #:GE CL01D310TD

NON-REVERSING TYPE UL 508, UL (CANADA AND US), CSA C22.2, CE, SETI, RINA APPROVAL 35 MM DIN RAIL/SCREW FRONT/SIDE MOUNT MOUNTING NEMA 1 ENCLOSURE 12 AMPERE AT 440 V 50/60 HZ (AC-3), 25 AMPERE (AC-1) CURRENT RATING 3 POLE(S) IEC, NEMA CONSTRUCTION STANDARD 24 VDC COIL VOLTAGE 1NO AUXILIARY CONTACT 4 HP AT 220/230 V, 7.5 HP AT 380/400/415/440 V, 10 HP AT 500 V, 3 KW AT 220/230 V, 5.5 KW AT 380/400/415/440 V, 7.5 KW AT 500 V POWER RATING/VOLTAGE APPLICABLE STANDARD IEC/EN 60947-1, IEC/EN 60947-4-1, IEC/EN 60947-5-1, EN 50005, VDE 0660, VDE 102 OPERATING TEMPERATURE -13 TO 131 DEG F MAXIMUM AUXILIARY CONTACTS 4 DEGREE OF PROTECTION IP20/IP10 CL MODEL
$ 133.00
Part #:GE CL02D310TD

NON-REVERSING TYPE UL 508, UL (CANADA AND US), CSA C22.2, CE, SETI, RINA APPROVAL 35 MM DIN RAIL/SCREW FRONT/SIDE MOUNT MOUNTING NEMA 1 ENCLOSURE 18 AMPERE AT 440 V 50/60 HZ (AC-3), 32 AMPERE (AC-1) CURRENT RATING 3 POLE(S) IEC, NEMA CONSTRUCTION STANDARD 24 VDC COIL VOLTAGE 1NO AUXILIARY CONTACT 5.5 HP AT 220/230 V, 10 HP AT 380/400/415/440 V, 13.5 HP AT 500 V, 4 KW AT 220/230 V, 7.5 KW AT 380/400/415/440 V, 10 KW AT 500 V POWER RATING/VOLTAGE APPLICABLE STANDARD IEC/EN 60947-1, IEC/EN 60947-4-1, IEC/EN 60947-5-1, EN 50005, VDE 0660, VDE 102 OPERATING TEMPERATURE -13 TO 131 DEG F MAXIMUM AUXILIARY CONTACTS 4 DEGREE OF PROTECTION IP20/IP10
$ 147.00
Part #:GE CL25A310TJ

NON-REVERSING TYPE UL 508, CSA C22.2, CE APPROVAL 35 MM DIN RAIL/SCREW FRONT MOUNT MOUNTING 32 AMPERE (UL CONTINUOUS), 45 AMPERE (IEC AC-1) CURRENT RATING 3 POLE(S) IEC CONSTRUCTION STANDARD 110 VAC AT 50 HZ, 120 VAC AT 60 HZ COIL VOLTAGE 1NO AUXILIARY CONTACT 1.5 HP AT 115 V 60 HZ, 3 HP AT 230 V 60 HZ 1-PHASE, 5 HP AT 200 V 60 HZ, 7.5 HP AT 230 V 60 HZ, 15 HP AT 460/575 V 60 HZ 3-PHASE, 11 KW AT 380/415 V 50 HZ POWER RATING/VOLTAGE APPLICABLE STANDARD IEC 947-1, IEC 947-4, EN 50005, VDE 0660, VDE 102 OPERATING TEMPERATURE -13 TO 131 DEG F MAXIMUM AUXILIARY CONTACTS 4 APPLICATION MOTOR LOAD AND DUTY CYCLE CL MODEL
$ 138.00
Part #:CWD S42-SP

ANGLED, POLARIZED TYPE THERMOPLASTIC MATERIAL BLACK COLOR 6-30P/6-50P CONFIGURATION 3 WIRE(S) 250 VAC VOLTAGE RATING 30/50 AMPERE CURRENT RATING GROUNDING 2 POLE(S) 1.1 INCH CORD SIZE ROHS/NAFTA COMPLIANT DIMENSION 2.87 INCH W X 1.38 INCH D X 3.37 INCH H APPROVAL UL 498, CSA C22.2, NOM 426
$ 24.79
Part #:HUBW HBL5266CA

ANGLED, POLARIZED TYPE NYLON MATERIAL BLACK, WHITE COLOR 5-15P CONFIGURATION 3 WIRE(S) UL 498, CSA C22.2 APPROVAL 125 V VOLTAGE RATING 15 AMPERE CURRENT RATING GROUNDING 2 POLE(S) 0.325 TO 0.655 INCH CORD SIZE INSULGRIP[R] BRAND BLADE MATERIAL 0.06 INCH BRASS ENCLOSURE IP20 OPERATING TEMPERATURE -40 TO 75 DEG C HBL MODEL
$ 36.70
Part #:HUBW HBL5366CA

ANGLED, POLARIZED TYPE NYLON MATERIAL BLACK, WHITE COLOR 5-20P CONFIGURATION 3 WIRE(S) UL 498, CSA C22.2 APPROVAL 125 V VOLTAGE RATING 20 AMPERE CURRENT RATING GROUNDING 2 POLE(S) 0.325 TO 0.655 INCH CORD SIZE INSULGRIP[R] BRAND BLADE MATERIAL 0.06 INCH BRASS ENCLOSURE IP20 OPERATING TEMPERATURE -40 TO 75 DEG C HBL MODEL
$ 47.26
Part #:GE CL45A310MJ

NON-REVERSING TYPE UL 508, CSA C22.2, CE APPROVAL 35 MM DIN RAIL/SCREW FRONT MOUNT MOUNTING 55 AMPERE (UL CONTINUOUS), 60 AMPERE (IEC AC-1) CURRENT RATING 3 POLE(S) IEC CONSTRUCTION STANDARD 110 VAC AT 50 HZ, 120 VAC AT 60 HZ COIL VOLTAGE 1NO AUXILIARY CONTACT 3 HP AT 115 V 60 HZ, 5 HP AT 230 V 60 HZ 1-PHASE, 10 HP AT 200/230 V 60 HZ, 25 HP AT 460/575 V 60 HZ 3-PHASE, 18.5 KW AT 380/415 V 50 HZ POWER RATING/VOLTAGE APPLICABLE STANDARD IEC 947-1, IEC 947-4, EN 50005, VDE 0660, VDE 102 OPERATING TEMPERATURE -13 TO 131 DEG F MAXIMUM AUXILIARY CONTACTS 6 APPLICATION MOTOR LOAD AND DUTY CYCLE CL MODEL
$ 173.00
closeout
Part #:EMERSON IC693ACC307

Availability: Out of stock
IC693ACC307 I/O BUS TERMINATOR PLUG 25PIN FOR 90-30 SERIES
$ 130.00
closeout
Part #:EMERSON IC693CBL300

CLOSEOUTS Only 2 Left!
Cable, I/O Base Expansion, 1 Meter, Shielded
$ 262.00
Part #:GE CL25D310TD

FULL VOLTAGE, NON REVERSING TYPE UL 508, CSA C22.2, CE APPROVAL 35 MM DIN RAIL/SCREW MOUNTING 32 AMPERE (UL CONTINUOUS), 45 AMPERE (IEC AC-1) CURRENT RATING 3 POLE(S) IEC CONSTRUCTION STANDARD 24 VDC COIL VOLTAGE 1NO FRONT MOUNTED AUXILIARY CONTACT 1.5 HP AT 115 V 60 HZ, 3 HP AT 230 V 60 HZ 1 PHASE 5 HP AT 200 V 60 HZ, 7.5 HP AT 230 V 60 HZ, 15 HP AT 460/575 V 60 HZ 3 PHASE 11 KW AT 380/415 V 50 HZ POWER RATING/VOLTAGE C-2000[T] BRAND APPLICABLE STANDARD IEC 947-1, IEC 947-4, EN 50005, VDE 0660, VDE 102 OPERATING TEMPERATURE -13 TO 131 DEG F MAXIMUM AUXILIARY CONTACTS 4 CL MODEL
$ 166.00
closeout
Part #:EMERSON IC693ALG221

CLOSEOUTS Only 4 Left!
Analog Input, Current, 4 Channel Analog I/O Modules (Input) GE offers easy-to-use analog modules for control processes such as flow, temperatureand pressure.
$ 2,475.00
closeout
Part #:EMERSON IC693ALG391

CLOSEOUTS Only 2 Left!
Analog Output, Current/Voltage, 2 Channel Analog I/O Modules (Output) GE offers easy-to-use analog modules for control processes such as flow, temperatureand pressure.
$ 2,399.00
closeout
Part #:EMERSON IC693MDL240

CLOSEOUTS Only 3 Left!
AC Voltage Input Module,120 VAC,16 Point Input Discrete I/O Modules (Input)Input modules provide the interface between the PLC and external input devices such as proximitysensors, push buttons, switches, and BCD thumbwheels. Output modules provide the interfacebetween the PLC and external output devices such as contactors, interposing relays, BCD displaysand indicator lamps. GE offers a variety of modules that support different voltage ranges andtypes, current capacity, isolation and response time tomeet your application needs.
$ 655.00
 
Displaying: 1 - 17 of 17 Matching Items