Part #:GE CL00A310TJ
- NON-REVERSING TYPE UL 508, UL (CANADA AND US), CSA C22.2, CE, SETI, RINA APPROVAL 35 MM DIN RAIL/SCREW FRONT/SIDE MOUNT MOUNTING NEMA 1 ENCLOSURE 9 AMPERE AT 440 V 50/60 HZ (AC-3), 25 AMPERE (AC-1) CURRENT RATING 3 POLE(S) IEC, NEMA CONSTRUCTION STANDARD 110 VAC AT 50 HZ, 125 VAC AT 60 HZ COIL VOLTAGE 1NO AUXILIARY CONTACT 3 HP AT 220/230 V, 5.5 HP AT 380/400/415/440 V, 7.5 HP AT 500 V, 2.2 KW AT 220/230 V, 4 KW AT 380/400/415/440 V, 5.5 KW AT 500 V POWER RATING/VOLTAGE APPLICABLE STANDARD IEC/EN 60947-1, IEC/EN 60947-4-1, IEC/EN 60947-5-1, EN 50005, VDE 0660, VDE 102 OPERATING TEMPERATURE -13 TO 131 DEG F MAXIMUM AUXILIARY CONTACTS 4 DEGREE OF PROTECTION IP20/IP10 CL MODEL
$
91.00
Qty:
Part #:GE CL01A310TJ
- NON-REVERSING TYPE UL 508, UL (CANADA AND US), CSA C22.2, CE, SETI, RINA APPROVAL 35 MM DIN RAIL/SCREW FRONT/SIDE MOUNT MOUNTING NEMA 1 ENCLOSURE 12 AMPERE AT 440 V 50/60 HZ (AC-3), 25 AMPERE (AC-1) CURRENT RATING 3 POLE(S) IEC, NEMA CONSTRUCTION STANDARD 110 VAC AT 50 HZ COIL VOLTAGE 1NO AUXILIARY CONTACT 4 HP AT 220/230 V, 7.5 HP AT 380/400/415/440 V, 10 HP AT 500 V, 3 KW AT 220/230 V, 5.5 KW AT 380/400/415/440 V, 7.5 KW AT 500 V POWER RATING/VOLTAGE APPLICABLE STANDARD IEC/EN 60947-1, IEC/EN 60947-4-1, IEC/EN 60947-5-1, EN 50005, VDE 0660, VDE 102 OPERATING TEMPERATURE -13 TO 131 DEG F MAXIMUM AUXILIARY CONTACTS 4 DEGREE OF PROTECTION IP20/IP10 CL MODEL
$
109.00
Qty:
Part #:GE CL02A310TJ
- NON-REVERSING TYPE UL 508, UL (CANADA AND US), CSA C22.2, CE, SETI, RINA APPROVAL 35 MM DIN RAIL/SCREW FRONT/SIDE MOUNT MOUNTING NEMA 1 ENCLOSURE 18 AMPERE AT 440 V 50/60 HZ (AC-3), 32 AMPERE (AC-1) CURRENT RATING 3 POLE(S) IEC, NEMA CONSTRUCTION STANDARD 110 VAC AT 50 HZ, 125 VAC AT 60 HZ COIL VOLTAGE 1NO AUXILIARY CONTACT 5.5 HP AT 220/230 V, 10 HP AT 380/400/415/440 V, 13.5 HP AT 500 V, 4 KW AT 220/230 V, 7.5 KW AT 380/400/415/440 V, 10 KW AT 500 V POWER RATING/VOLTAGE APPLICABLE STANDARD IEC/EN 60947-1, IEC/EN 60947-4-1, IEC/EN 60947-5-1, EN 50005, VDE 0660, VDE 102 OPERATING TEMPERATURE -13 TO 131 DEG F MAXIMUM AUXILIARY CONTACTS 4 DEGREE OF PROTECTION IP20/IP10 CL MODEL
$
124.00
Qty:
Part #:GE CL00D310TD
- NON-REVERSING TYPE UL 508, UL (CANADA AND US), CSA C22.2, CE, SETI, RINA APPROVAL 35 MM DIN RAIL/SCREW FRONT/SIDE MOUNT MOUNTING NEMA 1 ENCLOSURE 9 AMPERE AT 440 V 50/60 HZ (AC-3), 25 AMPERE (AC-1) CURRENT RATING 3 POLE(S) IEC, NEMA CONSTRUCTION STANDARD 24 VDC COIL VOLTAGE 1NO AUXILIARY CONTACT 3 HP AT 220/230 V, 5.5 HP AT 380/400/415/440 V, 7.5 HP AT 500 V, 2.2 KW AT 220/230 V, 4 KW AT 380/400/415/440 V, 5.5 KW AT 500 V POWER RATING/VOLTAGE APPLICABLE STANDARD IEC/EN 60947-1, IEC/EN 60947-4-1, IEC/EN 60947-5-1, EN 50005, VDE 0660, VDE 102 OPERATING TEMPERATURE -13 TO 131 DEG F MAXIMUM AUXILIARY CONTACTS 4 DEGREE OF PROTECTION IP20/IP10 CL MODEL
$
109.00
Qty:
Part #:GE CL01D310TD
- NON-REVERSING TYPE UL 508, UL (CANADA AND US), CSA C22.2, CE, SETI, RINA APPROVAL 35 MM DIN RAIL/SCREW FRONT/SIDE MOUNT MOUNTING NEMA 1 ENCLOSURE 12 AMPERE AT 440 V 50/60 HZ (AC-3), 25 AMPERE (AC-1) CURRENT RATING 3 POLE(S) IEC, NEMA CONSTRUCTION STANDARD 24 VDC COIL VOLTAGE 1NO AUXILIARY CONTACT 4 HP AT 220/230 V, 7.5 HP AT 380/400/415/440 V, 10 HP AT 500 V, 3 KW AT 220/230 V, 5.5 KW AT 380/400/415/440 V, 7.5 KW AT 500 V POWER RATING/VOLTAGE APPLICABLE STANDARD IEC/EN 60947-1, IEC/EN 60947-4-1, IEC/EN 60947-5-1, EN 50005, VDE 0660, VDE 102 OPERATING TEMPERATURE -13 TO 131 DEG F MAXIMUM AUXILIARY CONTACTS 4 DEGREE OF PROTECTION IP20/IP10 CL MODEL
$
133.00
Qty:
Part #:GE CL02D310TD
- NON-REVERSING TYPE UL 508, UL (CANADA AND US), CSA C22.2, CE, SETI, RINA APPROVAL 35 MM DIN RAIL/SCREW FRONT/SIDE MOUNT MOUNTING NEMA 1 ENCLOSURE 18 AMPERE AT 440 V 50/60 HZ (AC-3), 32 AMPERE (AC-1) CURRENT RATING 3 POLE(S) IEC, NEMA CONSTRUCTION STANDARD 24 VDC COIL VOLTAGE 1NO AUXILIARY CONTACT 5.5 HP AT 220/230 V, 10 HP AT 380/400/415/440 V, 13.5 HP AT 500 V, 4 KW AT 220/230 V, 7.5 KW AT 380/400/415/440 V, 10 KW AT 500 V POWER RATING/VOLTAGE APPLICABLE STANDARD IEC/EN 60947-1, IEC/EN 60947-4-1, IEC/EN 60947-5-1, EN 50005, VDE 0660, VDE 102 OPERATING TEMPERATURE -13 TO 131 DEG F MAXIMUM AUXILIARY CONTACTS 4 DEGREE OF PROTECTION IP20/IP10
$
147.00
Qty:
Part #:GE CL25A310TJ
- NON-REVERSING TYPE UL 508, CSA C22.2, CE APPROVAL 35 MM DIN RAIL/SCREW FRONT MOUNT MOUNTING 32 AMPERE (UL CONTINUOUS), 45 AMPERE (IEC AC-1) CURRENT RATING 3 POLE(S) IEC CONSTRUCTION STANDARD 110 VAC AT 50 HZ, 120 VAC AT 60 HZ COIL VOLTAGE 1NO AUXILIARY CONTACT 1.5 HP AT 115 V 60 HZ, 3 HP AT 230 V 60 HZ 1-PHASE, 5 HP AT 200 V 60 HZ, 7.5 HP AT 230 V 60 HZ, 15 HP AT 460/575 V 60 HZ 3-PHASE, 11 KW AT 380/415 V 50 HZ POWER RATING/VOLTAGE APPLICABLE STANDARD IEC 947-1, IEC 947-4, EN 50005, VDE 0660, VDE 102 OPERATING TEMPERATURE -13 TO 131 DEG F MAXIMUM AUXILIARY CONTACTS 4 APPLICATION MOTOR LOAD AND DUTY CYCLE CL MODEL
$
138.00
Qty:
Part #:GE THQL2120
- MOLDED CASE, FIXED THERMAL MAGNETIC, INTERNAL COMMON TRIP TYPE 2 INCH WIDTH X 2-3/8 INCH DEPTH X 3-9/32 INCH HEIGHT SIZE AL SERIES PANELBOARD USED ON 14 TO 8 AWG (COPPER), 12 TO 8 AWG (ALUMINUM) WIRE SIZE UL APPROVAL 120/240 VOLT AC VOLTAGE RATING 1 INCH PLUG-IN MOUNTING 10 KILOAMP INTERRUPTING RATING 20 AMP CURRENT RATING 2 POLE(S) COPPER/ALUMINUM LOAD LUG TERMINAL TYPE TRIP TYPE NON-INTERCHANGEABLE FRAME TYPE THQL TRIP FUNCTION LI APPLICATION HEATING, AIR CONDITIONING, REFRIGERATION THQL MODEL
$
48.00
Qty:
Part #:GE THQL2140
- MOLDED CASE, FIXED THERMAL MAGNETIC, INTERNAL COMMON TRIP TYPE 2 INCH WIDTH X 2-3/8 INCH DEPTH X 3-9/32 INCH HEIGHT SIZE AL SERIES PANELBOARD USED ON 8 TO 3 AWG (COPPER/ALUMINUM) WIRE SIZE UL APPROVAL 120/240 VOLT AC VOLTAGE RATING 1 INCH PLUG-IN MOUNTING 10 KILOAMP INTERRUPTING RATING 40 AMP CURRENT RATING 2 POLE(S) COPPER/ALUMINUM LOAD LUG TERMINAL TYPE TRIP TYPE NON-INTERCHANGEABLE FRAME TYPE THQL TRIP FUNCTION LI APPLICATION HEATING, AIR CONDITIONING, REFRIGERATION THQL MODEL
$
53.00
Qty:
Part #:SIEM5 Q115
- MINIATURE, THERMAL AND FIXED MAGNETIC TRIP TYPE 1 INCH WIDTH X 3 INCH DEPTH X 3-1/8 INCH HEIGHT SIZE LOAD CENTER USED ON 14 TO 6 AWG (COPPER/ALUMINUM) WIRE SIZE UL 489 APPROVAL 120 VOLT AC VOLTAGE RATING PLUG-IN MOUNTING 10 KILOAMP INTERRUPTING RATING 15 AMP AT 40 DEG C CURRENT RATING 1 POLE(S) LOAD LUG TERMINAL TYPE SPEEDFAX[TM], INSTA-WIRE BRAND FRAME TYPE QP QP MODEL
$
78.72
Qty:
Part #:SIEM5 Q230
- MINIATURE, THERMAL AND FIXED MAGNETIC TRIP, COMMON TRIP TYPE 2 INCH WIDTH X 3 INCH DEPTH X 3-1/8 INCH HEIGHT SIZE LOAD CENTER USED ON 14 TO 6 AWG (COPPER/ALUMINUM) WIRE SIZE UL 489 APPROVAL 120/240 VOLT AC VOLTAGE RATING PLUG-IN MOUNTING 10 KILOAMP INTERRUPTING RATING 30 AMP AT 40 DEG C CURRENT RATING 2 POLE(S) LOAD LUG TERMINAL TYPE SPEEDFAX[TM], INSTA-WIRE BRAND FRAME TYPE QP QP MODEL
$
161.14
Qty:
Part #:GE EP101ULH3C01
- Circuit Breaker, 1 Pole, C-Curve, 1A, UL489, 277V 10kA, 480Y/277VAC, 60/125VDC
EP100 UL
UL1077
10kA
C trip curves
277/480VAC, 50/110VDC
$
122.00
Qty:
Part #:GE CL45A310MJ
- NON-REVERSING TYPE UL 508, CSA C22.2, CE APPROVAL 35 MM DIN RAIL/SCREW FRONT MOUNT MOUNTING 55 AMPERE (UL CONTINUOUS), 60 AMPERE (IEC AC-1) CURRENT RATING 3 POLE(S) IEC CONSTRUCTION STANDARD 110 VAC AT 50 HZ, 120 VAC AT 60 HZ COIL VOLTAGE 1NO AUXILIARY CONTACT 3 HP AT 115 V 60 HZ, 5 HP AT 230 V 60 HZ 1-PHASE, 10 HP AT 200/230 V 60 HZ, 25 HP AT 460/575 V 60 HZ 3-PHASE, 18.5 KW AT 380/415 V 50 HZ POWER RATING/VOLTAGE APPLICABLE STANDARD IEC 947-1, IEC 947-4, EN 50005, VDE 0660, VDE 102 OPERATING TEMPERATURE -13 TO 131 DEG F MAXIMUM AUXILIARY CONTACTS 6 APPLICATION MOTOR LOAD AND DUTY CYCLE CL MODEL
$
173.00
Qty:
Part #:GE THQB2115
- MOLDED CASE, FIXED THERMAL MAGNETIC, INTERNAL COMMON TRIP TYPE 2 INCH W X 2-3/8 INCH D X 3-9/32 INCH H SIZE AQ SERIES PANELBOARD USED ON 14 TO 8 AWG (COPPER)/12 TO 8 AWG (ALUMINUM) WIRE SIZE UL APPROVAL 120/240 VAC VOLTAGE RATING 1 INCH BOLT-ON MOUNTING 10 KILOAMPERE INTERRUPTING RATING 15 AMPERE CURRENT RATING 2 POLE(S) COPPER/ALUMINUM LOAD LUG, BOLT-ON TERMINAL TYPE TRIP TYPE NON-INTERCHANGEABLE FRAME TYPE THQB TRIP FUNCTION LI APPLICATION HEATING, AIR CONDITIONING, REFRIGERATION SERIES THQB MODEL
$
78.00
Qty:
Part #:GE THQB2150
- MOLDED CASE, FIXED THERMAL MAGNETIC, INTERNAL COMMON TRIP TYPE 2 INCH W X 2-3/8 INCH D X 3-9/32 INCH H SIZE AQ SERIES PANELBOARD USED ON 8 TO 3 AWG (COPPER/ALUMINUM) WIRE SIZE UL APPROVAL 120/240 VAC VOLTAGE RATING 1 INCH BOLT-ON MOUNTING 10 KILOAMPERE INTERRUPTING RATING 50 AMPERE CURRENT RATING 2 POLE(S) COPPER/ALUMINUM LOAD LUG, BOLT-ON TERMINAL TYPE TRIP TYPE NON-INTERCHANGEABLE FRAME TYPE THQB TRIP FUNCTION LI APPLICATION HEATING, AIR CONDITIONING, REFRIGERATION SERIES THQB MODEL
$
78.00
Qty:
Part #:GE THQP220
- MOLDED CASE, FIXED THERMAL MAGNETIC, INTERNAL COMMON TRIP TYPE 1 INCH WIDTH X 2-3/8 INCH DEPTH X 3-9/32 INCH HEIGHT SIZE 14 TO 8 AWG (COPPER), 12 TO 8 AWG (ALUMINUM) WIRE SIZE UL APPROVAL 120/240 VOLT AC VOLTAGE RATING 1/2 INCH PLUG-IN MOUNTING 10 KILOAMP INTERRUPTING RATING 20 AMP CURRENT RATING 2 POLE(S) COPPER/ALUMINUM LOAD LUG TERMINAL TYPE TRIP TYPE NON-INTERCHANGEABLE FRAME TYPE THQP TRIP FUNCTION LI APPLICATION HEATING, AIR CONDITIONING, REFRIGERATION THQP MODEL
$
48.00
Qty:
Part #:SIEM5 Q290
- MINIATURE, THERMAL AND FIXED MAGNETIC TRIP, COMMON TRIP TYPE 2 INCH WIDTH X 3 INCH DEPTH X 3-1/8 INCH HEIGHT SIZE LOAD CENTER USED ON 8 TO 2/0 AWG (COPPER/ALUMINUM) WIRE SIZE UL 489 APPROVAL 120/240 VOLT AC VOLTAGE RATING PLUG-IN MOUNTING 10 KILOAMP INTERRUPTING RATING 90 AMP AT 40 DEG C CURRENT RATING 2 POLE(S) LOAD LUG TERMINAL TYPE SPEEDFAX[TM], INSTA-WIRE BRAND FRAME TYPE QP QP MODEL
$
470.68
Qty:
Part #:SIEM5 Q1515NC
- MINIATURE, THERMAL AND FIXED MAGNETIC TRIP, DUPLEX TYPE 1 INCH WIDTH X 2.06 INCH DEPTH X 3.12 INCH HEIGHT SIZE LOAD CENTER USED ON 14 TO 6 AWG (COPPER/ALUMINUM) WIRE SIZE UL 489 APPROVAL 120 VOLT AC VOLTAGE RATING PLUG-IN MOUNTING 10 KILOAMP INTERRUPTING RATING 15 AMP CURRENT RATING 1 POLE(S) LOAD LUG TERMINAL TYPE SPEEDFAX[TM] BRAND FRAME TYPE QT APPLICATION HEATING, AIR CONDITIONING, REFRIGERATION QT MODEL
$
282.08
Qty:
Part #:SIEM5 B120H
- MOLDED CASE, THERMAL AND FIXED MAGNETIC, BRANCH TYPE P1/P2/P3/P4/P5 PANELBOARD USED ON BOLT-ON INSTALLATION UL 489, CSA C22.2 APPROVAL LIGHTING, DISTRIBUTION APPLICATION 120 VOLT AC AT 50/60 HERTZ VOLTAGE RATING 22 KILOAMP AT 120 VOLT AC INTERRUPTING RATING 20 AMP AT 40 DEG C CURRENT RATING 1 POLE(S) SPEEDFAX[TM] BRAND FRAME TYPE BLH TERMINAL TYPE BOLT-ON OVERALL DIMENSION 1 INCH WIDTH X 3 INCH DEPTH X 3-9/16 INCH HEIGHT
$
204.48
Qty:
Part #:SIEM5 ECCS1
- 14 TO 1/0 AWG (COPPER/ALUMINUM) COLLAR STRAP TYPE LOAD CENTER GROUND BAR USED ON DEPTH 248.2 INCH APPLICATION RESIDENTIAL
$
18.82
Qty:
Part #:SIEM6 QF115A
- CIRCUIT PROTECTOR TYPE LOADCENTER USED ON 120 VAC VOLTAGE RATING PLUG-IN MOUNTING 10 KILOAMPERE INTERRUPTING RATING 15 AMPERE CURRENT RATING 1 POLE(S) 5 MILLIAMPERE TRIP SENSITIVITY
$
405.40
Qty:
Part #:SIEM5 ECGB10
- ULTIMATE LOAD CENTER USED ON COPPER/ALUMINUM CONDUCTOR MATERIAL 10-TERMINAL (14 TO 4 AWG) TERMINAL SIZE SPEEDFAX[TM] BRAND
$
60.04
Qty:
Part #:GE CL25D310TD
- FULL VOLTAGE, NON REVERSING TYPE UL 508, CSA C22.2, CE APPROVAL 35 MM DIN RAIL/SCREW MOUNTING 32 AMPERE (UL CONTINUOUS), 45 AMPERE (IEC AC-1) CURRENT RATING 3 POLE(S) IEC CONSTRUCTION STANDARD 24 VDC COIL VOLTAGE 1NO FRONT MOUNTED AUXILIARY CONTACT 1.5 HP AT 115 V 60 HZ, 3 HP AT 230 V 60 HZ 1 PHASE 5 HP AT 200 V 60 HZ, 7.5 HP AT 230 V 60 HZ, 15 HP AT 460/575 V 60 HZ 3 PHASE 11 KW AT 380/415 V 50 HZ POWER RATING/VOLTAGE C-2000[T] BRAND APPLICABLE STANDARD IEC 947-1, IEC 947-4, EN 50005, VDE 0660, VDE 102 OPERATING TEMPERATURE -13 TO 131 DEG F MAXIMUM AUXILIARY CONTACTS 4 CL MODEL
$
166.00
Qty:
Part #:GE THQB2120
- MOLDED CASE, FIXED THERMAL MAGNETIC, INTERNAL COMMON TRIP TYPE 2 INCH WIDTH X 2-3/8 INCH DEPTH X 3-9/32 INCH HEIGHT SIZE AQ SERIES PANELBOARD USED ON 14 TO 8 AWG (COPPER), 12 TO 8 AWG (ALUMINUM) WIRE SIZE UL APPROVAL 120/240 VOLT AC VOLTAGE RATING 1 INCH BOLT-ON MOUNTING 10 KILOAMP INTERRUPTING RATING 20 AMP CURRENT RATING 2 POLE(S) COPPER/ALUMINUM LOAD LUG TERMINAL TYPE TRIP TYPE NON-INTERCHANGEABLE FRAME TYPE THQB TRIP FUNCTION LI APPLICATION HEATING, AIR CONDITIONING, REFRIGERATION THQB MODEL
$
78.00
Qty:
Displaying: 1 - 24 of 32 Matching Items