Full Voltage, Non Reversing
Electrical Insulating, No Adhesive


Displaying: 1 - 17 of 17 Matching Items
17 Items
View:
Part #:GE CL00A310TJ

NON-REVERSING TYPE UL 508, UL (CANADA AND US), CSA C22.2, CE, SETI, RINA APPROVAL 35 MM DIN RAIL/SCREW FRONT/SIDE MOUNT MOUNTING NEMA 1 ENCLOSURE 9 AMPERE AT 440 V 50/60 HZ (AC-3), 25 AMPERE (AC-1) CURRENT RATING 3 POLE(S) IEC, NEMA CONSTRUCTION STANDARD 110 VAC AT 50 HZ, 125 VAC AT 60 HZ COIL VOLTAGE 1NO AUXILIARY CONTACT 3 HP AT 220/230 V, 5.5 HP AT 380/400/415/440 V, 7.5 HP AT 500 V, 2.2 KW AT 220/230 V, 4 KW AT 380/400/415/440 V, 5.5 KW AT 500 V POWER RATING/VOLTAGE APPLICABLE STANDARD IEC/EN 60947-1, IEC/EN 60947-4-1, IEC/EN 60947-5-1, EN 50005, VDE 0660, VDE 102 OPERATING TEMPERATURE -13 TO 131 DEG F MAXIMUM AUXILIARY CONTACTS 4 DEGREE OF PROTECTION IP20/IP10 CL MODEL
$ 91.00
Part #:GE CL01A310TJ

NON-REVERSING TYPE UL 508, UL (CANADA AND US), CSA C22.2, CE, SETI, RINA APPROVAL 35 MM DIN RAIL/SCREW FRONT/SIDE MOUNT MOUNTING NEMA 1 ENCLOSURE 12 AMPERE AT 440 V 50/60 HZ (AC-3), 25 AMPERE (AC-1) CURRENT RATING 3 POLE(S) IEC, NEMA CONSTRUCTION STANDARD 110 VAC AT 50 HZ COIL VOLTAGE 1NO AUXILIARY CONTACT 4 HP AT 220/230 V, 7.5 HP AT 380/400/415/440 V, 10 HP AT 500 V, 3 KW AT 220/230 V, 5.5 KW AT 380/400/415/440 V, 7.5 KW AT 500 V POWER RATING/VOLTAGE APPLICABLE STANDARD IEC/EN 60947-1, IEC/EN 60947-4-1, IEC/EN 60947-5-1, EN 50005, VDE 0660, VDE 102 OPERATING TEMPERATURE -13 TO 131 DEG F MAXIMUM AUXILIARY CONTACTS 4 DEGREE OF PROTECTION IP20/IP10 CL MODEL
$ 109.00
Part #:GE CL02A310TJ

NON-REVERSING TYPE UL 508, UL (CANADA AND US), CSA C22.2, CE, SETI, RINA APPROVAL 35 MM DIN RAIL/SCREW FRONT/SIDE MOUNT MOUNTING NEMA 1 ENCLOSURE 18 AMPERE AT 440 V 50/60 HZ (AC-3), 32 AMPERE (AC-1) CURRENT RATING 3 POLE(S) IEC, NEMA CONSTRUCTION STANDARD 110 VAC AT 50 HZ, 125 VAC AT 60 HZ COIL VOLTAGE 1NO AUXILIARY CONTACT 5.5 HP AT 220/230 V, 10 HP AT 380/400/415/440 V, 13.5 HP AT 500 V, 4 KW AT 220/230 V, 7.5 KW AT 380/400/415/440 V, 10 KW AT 500 V POWER RATING/VOLTAGE APPLICABLE STANDARD IEC/EN 60947-1, IEC/EN 60947-4-1, IEC/EN 60947-5-1, EN 50005, VDE 0660, VDE 102 OPERATING TEMPERATURE -13 TO 131 DEG F MAXIMUM AUXILIARY CONTACTS 4 DEGREE OF PROTECTION IP20/IP10 CL MODEL
$ 124.00
Part #:GE CL00D310TD

NON-REVERSING TYPE UL 508, UL (CANADA AND US), CSA C22.2, CE, SETI, RINA APPROVAL 35 MM DIN RAIL/SCREW FRONT/SIDE MOUNT MOUNTING NEMA 1 ENCLOSURE 9 AMPERE AT 440 V 50/60 HZ (AC-3), 25 AMPERE (AC-1) CURRENT RATING 3 POLE(S) IEC, NEMA CONSTRUCTION STANDARD 24 VDC COIL VOLTAGE 1NO AUXILIARY CONTACT 3 HP AT 220/230 V, 5.5 HP AT 380/400/415/440 V, 7.5 HP AT 500 V, 2.2 KW AT 220/230 V, 4 KW AT 380/400/415/440 V, 5.5 KW AT 500 V POWER RATING/VOLTAGE APPLICABLE STANDARD IEC/EN 60947-1, IEC/EN 60947-4-1, IEC/EN 60947-5-1, EN 50005, VDE 0660, VDE 102 OPERATING TEMPERATURE -13 TO 131 DEG F MAXIMUM AUXILIARY CONTACTS 4 DEGREE OF PROTECTION IP20/IP10 CL MODEL
$ 109.00
Part #:GE CL01D310TD

NON-REVERSING TYPE UL 508, UL (CANADA AND US), CSA C22.2, CE, SETI, RINA APPROVAL 35 MM DIN RAIL/SCREW FRONT/SIDE MOUNT MOUNTING NEMA 1 ENCLOSURE 12 AMPERE AT 440 V 50/60 HZ (AC-3), 25 AMPERE (AC-1) CURRENT RATING 3 POLE(S) IEC, NEMA CONSTRUCTION STANDARD 24 VDC COIL VOLTAGE 1NO AUXILIARY CONTACT 4 HP AT 220/230 V, 7.5 HP AT 380/400/415/440 V, 10 HP AT 500 V, 3 KW AT 220/230 V, 5.5 KW AT 380/400/415/440 V, 7.5 KW AT 500 V POWER RATING/VOLTAGE APPLICABLE STANDARD IEC/EN 60947-1, IEC/EN 60947-4-1, IEC/EN 60947-5-1, EN 50005, VDE 0660, VDE 102 OPERATING TEMPERATURE -13 TO 131 DEG F MAXIMUM AUXILIARY CONTACTS 4 DEGREE OF PROTECTION IP20/IP10 CL MODEL
$ 133.00
Part #:GE CL02D310TD

NON-REVERSING TYPE UL 508, UL (CANADA AND US), CSA C22.2, CE, SETI, RINA APPROVAL 35 MM DIN RAIL/SCREW FRONT/SIDE MOUNT MOUNTING NEMA 1 ENCLOSURE 18 AMPERE AT 440 V 50/60 HZ (AC-3), 32 AMPERE (AC-1) CURRENT RATING 3 POLE(S) IEC, NEMA CONSTRUCTION STANDARD 24 VDC COIL VOLTAGE 1NO AUXILIARY CONTACT 5.5 HP AT 220/230 V, 10 HP AT 380/400/415/440 V, 13.5 HP AT 500 V, 4 KW AT 220/230 V, 7.5 KW AT 380/400/415/440 V, 10 KW AT 500 V POWER RATING/VOLTAGE APPLICABLE STANDARD IEC/EN 60947-1, IEC/EN 60947-4-1, IEC/EN 60947-5-1, EN 50005, VDE 0660, VDE 102 OPERATING TEMPERATURE -13 TO 131 DEG F MAXIMUM AUXILIARY CONTACTS 4 DEGREE OF PROTECTION IP20/IP10
$ 147.00
Part #:GE CL25A310TJ

NON-REVERSING TYPE UL 508, CSA C22.2, CE APPROVAL 35 MM DIN RAIL/SCREW FRONT MOUNT MOUNTING 32 AMPERE (UL CONTINUOUS), 45 AMPERE (IEC AC-1) CURRENT RATING 3 POLE(S) IEC CONSTRUCTION STANDARD 110 VAC AT 50 HZ, 120 VAC AT 60 HZ COIL VOLTAGE 1NO AUXILIARY CONTACT 1.5 HP AT 115 V 60 HZ, 3 HP AT 230 V 60 HZ 1-PHASE, 5 HP AT 200 V 60 HZ, 7.5 HP AT 230 V 60 HZ, 15 HP AT 460/575 V 60 HZ 3-PHASE, 11 KW AT 380/415 V 50 HZ POWER RATING/VOLTAGE APPLICABLE STANDARD IEC 947-1, IEC 947-4, EN 50005, VDE 0660, VDE 102 OPERATING TEMPERATURE -13 TO 131 DEG F MAXIMUM AUXILIARY CONTACTS 4 APPLICATION MOTOR LOAD AND DUTY CYCLE CL MODEL
$ 138.00
Part #:3M 2510-3/4X60FT

Straight-cut, woven, cotton-cloth backing is oil-primed and coated with yellow, electrical, insulating varnish Excellent dielectric strength Suitable for insulating bus bars, motor leads and service drop connections Wide and narrow width electrical tape available (0.75 in &ndash 2 in.) Temperature stable with an operating range of 32&degF (0&degC) to 220&degF (105&degC) Withstands a temperature range of 32 to 221 degrees F (0 to 105 degrees C) Withstands a temperature range of 32 to 221 degrees F (0 to 105 degrees C) ASTM Approved and RoHS 2011/65/EU Compliant Yellow, varnish coated cotton cloth, no adhesive. Insulate bus bars, motor leads (for re-entry), service drop connections. Scotch&reg Tape 2510 has a straight-cut, woven cotton, cambric fabric backing that provides high tensile strength and ruggedness. This fabric is coated and oil-primed with yellow electrical insulating varnish. This moisture-resistant tape offers excellent dielectric strength with cut-through and puncture resistance. ASTM Approved and RoHS 2011/65/EU Compliant.
$ 59.78
Part #:GE THQL2120

MOLDED CASE, FIXED THERMAL MAGNETIC, INTERNAL COMMON TRIP TYPE 2 INCH WIDTH X 2-3/8 INCH DEPTH X 3-9/32 INCH HEIGHT SIZE AL SERIES PANELBOARD USED ON 14 TO 8 AWG (COPPER), 12 TO 8 AWG (ALUMINUM) WIRE SIZE UL APPROVAL 120/240 VOLT AC VOLTAGE RATING 1 INCH PLUG-IN MOUNTING 10 KILOAMP INTERRUPTING RATING 20 AMP CURRENT RATING 2 POLE(S) COPPER/ALUMINUM LOAD LUG TERMINAL TYPE TRIP TYPE NON-INTERCHANGEABLE FRAME TYPE THQL TRIP FUNCTION LI APPLICATION HEATING, AIR CONDITIONING, REFRIGERATION THQL MODEL
$ 48.00
Part #:GE THQL2140

MOLDED CASE, FIXED THERMAL MAGNETIC, INTERNAL COMMON TRIP TYPE 2 INCH WIDTH X 2-3/8 INCH DEPTH X 3-9/32 INCH HEIGHT SIZE AL SERIES PANELBOARD USED ON 8 TO 3 AWG (COPPER/ALUMINUM) WIRE SIZE UL APPROVAL 120/240 VOLT AC VOLTAGE RATING 1 INCH PLUG-IN MOUNTING 10 KILOAMP INTERRUPTING RATING 40 AMP CURRENT RATING 2 POLE(S) COPPER/ALUMINUM LOAD LUG TERMINAL TYPE TRIP TYPE NON-INTERCHANGEABLE FRAME TYPE THQL TRIP FUNCTION LI APPLICATION HEATING, AIR CONDITIONING, REFRIGERATION THQL MODEL
$ 53.00
Part #:GE CL45A310MJ

NON-REVERSING TYPE UL 508, CSA C22.2, CE APPROVAL 35 MM DIN RAIL/SCREW FRONT MOUNT MOUNTING 55 AMPERE (UL CONTINUOUS), 60 AMPERE (IEC AC-1) CURRENT RATING 3 POLE(S) IEC CONSTRUCTION STANDARD 110 VAC AT 50 HZ, 120 VAC AT 60 HZ COIL VOLTAGE 1NO AUXILIARY CONTACT 3 HP AT 115 V 60 HZ, 5 HP AT 230 V 60 HZ 1-PHASE, 10 HP AT 200/230 V 60 HZ, 25 HP AT 460/575 V 60 HZ 3-PHASE, 18.5 KW AT 380/415 V 50 HZ POWER RATING/VOLTAGE APPLICABLE STANDARD IEC 947-1, IEC 947-4, EN 50005, VDE 0660, VDE 102 OPERATING TEMPERATURE -13 TO 131 DEG F MAXIMUM AUXILIARY CONTACTS 6 APPLICATION MOTOR LOAD AND DUTY CYCLE CL MODEL
$ 173.00
Part #:GE THQB2115

MOLDED CASE, FIXED THERMAL MAGNETIC, INTERNAL COMMON TRIP TYPE 2 INCH W X 2-3/8 INCH D X 3-9/32 INCH H SIZE AQ SERIES PANELBOARD USED ON 14 TO 8 AWG (COPPER)/12 TO 8 AWG (ALUMINUM) WIRE SIZE UL APPROVAL 120/240 VAC VOLTAGE RATING 1 INCH BOLT-ON MOUNTING 10 KILOAMPERE INTERRUPTING RATING 15 AMPERE CURRENT RATING 2 POLE(S) COPPER/ALUMINUM LOAD LUG, BOLT-ON TERMINAL TYPE TRIP TYPE NON-INTERCHANGEABLE FRAME TYPE THQB TRIP FUNCTION LI APPLICATION HEATING, AIR CONDITIONING, REFRIGERATION SERIES THQB MODEL
$ 78.00
Part #:GE THQB2150

MOLDED CASE, FIXED THERMAL MAGNETIC, INTERNAL COMMON TRIP TYPE 2 INCH W X 2-3/8 INCH D X 3-9/32 INCH H SIZE AQ SERIES PANELBOARD USED ON 8 TO 3 AWG (COPPER/ALUMINUM) WIRE SIZE UL APPROVAL 120/240 VAC VOLTAGE RATING 1 INCH BOLT-ON MOUNTING 10 KILOAMPERE INTERRUPTING RATING 50 AMPERE CURRENT RATING 2 POLE(S) COPPER/ALUMINUM LOAD LUG, BOLT-ON TERMINAL TYPE TRIP TYPE NON-INTERCHANGEABLE FRAME TYPE THQB TRIP FUNCTION LI APPLICATION HEATING, AIR CONDITIONING, REFRIGERATION SERIES THQB MODEL
$ 78.00
Part #:GE THQP220

MOLDED CASE, FIXED THERMAL MAGNETIC, INTERNAL COMMON TRIP TYPE 1 INCH WIDTH X 2-3/8 INCH DEPTH X 3-9/32 INCH HEIGHT SIZE 14 TO 8 AWG (COPPER), 12 TO 8 AWG (ALUMINUM) WIRE SIZE UL APPROVAL 120/240 VOLT AC VOLTAGE RATING 1/2 INCH PLUG-IN MOUNTING 10 KILOAMP INTERRUPTING RATING 20 AMP CURRENT RATING 2 POLE(S) COPPER/ALUMINUM LOAD LUG TERMINAL TYPE TRIP TYPE NON-INTERCHANGEABLE FRAME TYPE THQP TRIP FUNCTION LI APPLICATION HEATING, AIR CONDITIONING, REFRIGERATION THQP MODEL
$ 48.00
Part #:GE CL25D310TD

FULL VOLTAGE, NON REVERSING TYPE UL 508, CSA C22.2, CE APPROVAL 35 MM DIN RAIL/SCREW MOUNTING 32 AMPERE (UL CONTINUOUS), 45 AMPERE (IEC AC-1) CURRENT RATING 3 POLE(S) IEC CONSTRUCTION STANDARD 24 VDC COIL VOLTAGE 1NO FRONT MOUNTED AUXILIARY CONTACT 1.5 HP AT 115 V 60 HZ, 3 HP AT 230 V 60 HZ 1 PHASE 5 HP AT 200 V 60 HZ, 7.5 HP AT 230 V 60 HZ, 15 HP AT 460/575 V 60 HZ 3 PHASE 11 KW AT 380/415 V 50 HZ POWER RATING/VOLTAGE C-2000[T] BRAND APPLICABLE STANDARD IEC 947-1, IEC 947-4, EN 50005, VDE 0660, VDE 102 OPERATING TEMPERATURE -13 TO 131 DEG F MAXIMUM AUXILIARY CONTACTS 4 CL MODEL
$ 166.00
Part #:GE THQB2120

MOLDED CASE, FIXED THERMAL MAGNETIC, INTERNAL COMMON TRIP TYPE 2 INCH WIDTH X 2-3/8 INCH DEPTH X 3-9/32 INCH HEIGHT SIZE AQ SERIES PANELBOARD USED ON 14 TO 8 AWG (COPPER), 12 TO 8 AWG (ALUMINUM) WIRE SIZE UL APPROVAL 120/240 VOLT AC VOLTAGE RATING 1 INCH BOLT-ON MOUNTING 10 KILOAMP INTERRUPTING RATING 20 AMP CURRENT RATING 2 POLE(S) COPPER/ALUMINUM LOAD LUG TERMINAL TYPE TRIP TYPE NON-INTERCHANGEABLE FRAME TYPE THQB TRIP FUNCTION LI APPLICATION HEATING, AIR CONDITIONING, REFRIGERATION THQB MODEL
$ 78.00
Part #:GE THQB2160

MOLDED CASE, FIXED THERMAL MAGNETIC, INTERNAL COMMON TRIP TYPE 2 INCH WIDTH X 2-3/8 INCH DEPTH X 3-9/32 INCH HEIGHT SIZE AQ SERIES PANELBOARD USED ON 8 TO 3 AWG (COPPER/ALUMINUM) WIRE SIZE UL APPROVAL 120/240 VOLT AC VOLTAGE RATING 1 INCH BOLT-ON MOUNTING 10 KILOAMP INTERRUPTING RATING 60 AMP CURRENT RATING 2 POLE(S) COPPER/ALUMINUM LOAD LUG TERMINAL TYPE TRIP TYPE NON-INTERCHANGEABLE FRAME TYPE THQB TRIP FUNCTION LI APPLICATION HEATING, AIR CONDITIONING, REFRIGERATION THQB MODEL
$ 78.00
 
Displaying: 1 - 17 of 17 Matching Items