Part #:BUSS FRS-R-40
- CLASS RK5 TYPE 5.5 INCH UL 248-12, CSA C22.2, CE APPROVAL 600 VOLT AC, 250 VOLT DC VOLTAGE RATING 1.06 INCH DIAMETER 200 KILOAMP SYMMETRICAL (AC), 20 KILOAMP (DC) INTERRUPTING RATING 40 AMP CURRENT RATING FERRULE WITH GROOVED RING TERMINAL TYPE 10 SECOND TIME DELAY AT 500 PERCENT RATED LOAD, DUAL ELEMENT, NON-INDICATING CHARACTERISTICS FUSETRON[TM] BRAND APPLICATION POWER PANELBOARD, MOTOR CONTROL CENTER, COMBINATION STARTER, MACHINERY DISCONNECT FRS-R MODEL
$
92.52
Qty:
Part #:BUSS LPJ-40SP
- CLASS J TYPE 2.38 INCH UL, CSA C22.2, CE APPROVAL 600 VAC/300 VDC VOLTAGE RATING 1.06 INCH DIAMETER 300 KILOAMPERE (SYMMETRICAL), 100 KILOAMPERE (DC) INTERRUPTING RATING 40 AMPERE CURRENT RATING FERRULE TERMINAL TYPE 10 SEC TIME DELAY (AT 500 PERCENT RATED LOAD), DUAL ELEMENT, NON-INDICATING CHARACTERISTICS LOW-PEAK[TM] BRAND ROHS COMPLIANT APPLICATION POWER PANELBOARD, BRANCH CIRCUIT BREAKER PANELBOARD MAIN, MACHINERY DISCONNECT, INDUSTRIAL CONTROL SERIES LPJ MODEL
$
167.58
Qty:
closeout
Part #:GE CR123C196A
- CLOSEOUTS Only 4 Left!
- CR124C SERIES OVERLOAD RELAY, CR1062R/CR1062S SERIES MANUAL STARTER, CR340/CR341 SERIES PUMPING PANEL USED ON PANEL MOUNTING 3 STANDARD PACKAGE 0, 1, M-0, M-1 NEMA SIZE 1.72 TO 1.91 AMPERE (1-PHASE 2 HEATER UNIT), 1.56 TO 1.73 AMPERE (3-PHASE 3 HEATER UNIT) MOTOR FLA CLASS 20, STANDARD TRIP TYPE
$
9.00
Qty:
Part #:BUSS FRS-R-60
- CLASS RK5 TYPE 5.5 INCH UL 248-12, CSA C22.2, CE APPROVAL 600 VOLT AC, 250 VOLT DC VOLTAGE RATING 1.06 INCH DIAMETER 200 KILOAMP SYMMETRICAL (AC), 20 KILOAMP (DC) INTERRUPTING RATING 60 AMP CURRENT RATING FERRULE WITH GROOVED RING TERMINAL TYPE 10 SECOND TIME DELAY AT 500 PERCENT RATED LOAD, DUAL ELEMENT, NON-INDICATING CHARACTERISTICS FUSETRON[TM] BRAND APPLICATION POWER PANELBOARD, MOTOR CONTROL CENTER, COMBINATION STARTER, MACHINERY DISCONNECT FRS-R MODEL
$
92.52
Qty:
closeout
Part #:GE CR123C250B
- CLOSEOUTS Only 3 Left!
- CR124C/CR124D SERIES OVERLOAD RELAY, CR1062R/CR1062S/CR1062T SERIES STARTER, CR340/CR341 SERIES PUMPING PANEL USED ON PANEL MOUNTING 3 STANDARD PACKAGE 0, 1, 2, M-0, M-1, M-1P NEMA SIZE 24 TO 27.8 AMPERE (1-PHASE 2 HEATER UNIT), 21.6 TO 24.7 AMPERE (3-PHASE 3 HEATER UNIT) MOTOR FLA CLASS 20, STANDARD TRIP TYPE CR123C MODEL
$
9.00
Qty:
Part #:GE CR123C326A
- CR124C SERIES OVERLOAD RELAY, CR1062R/CR1062S SERIES MANUAL STARTER, CR340/CR341 SERIES PUMPING PANEL USED ON PANEL MOUNTING 3 STANDARD PACKAGE 0, 1, M-0, M-1 NEMA SIZE 2.77 TO 3.19 AMPERE (1-PHASE 2 HEATER UNIT), 2.48 TO 387 AMPERE (3-PHASE 3 HEATER UNIT) MOTOR FLA CLASS 20, STANDARD TRIP TYPE
$
9.00
Qty:
closeout
Part #:GE CR123C366B
- CLOSEOUTS Only 3 Left!
- CR124D/CR324D SERIES OVERLOAD RELAY, CR340/CR341 SERIES PUMPING PANEL USED ON PANEL MOUNTING 3 STANDARD PACKAGE 2, M-1P NEMA SIZE 35.4 TO 40.9 AMP (1-PHASE 2-HEATER UNIT), 32.6 TO 36.7 AMP (3-PHASE 3-HEATER UNIT) MOTOR FLA CLASS 20, STANDARD TRIP TYPE SPECTRA SERIES[TM] BRAND CR123C MODEL
$
9.00
Qty:
Part #:BUSS LPJ-80SP
- CLASS J TYPE 4.63 INCH UL, CSA C22.2, CE APPROVAL 600 VAC/300 VDC VOLTAGE RATING 1.13 INCH DIAMETER 300 KILOAMPERE (SYMMETRICAL), 100 KILOAMPERE (DC) INTERRUPTING RATING 80 AMPERE CURRENT RATING BLADE TERMINAL TYPE 10 SEC TIME DELAY (AT 500 PERCENT RATED LOAD), DUAL ELEMENT, NON-INDICATING CHARACTERISTICS LOW-PEAK[TM] BRAND ROHS COMPLIANT APPLICATION POWER PANELBOARD, BRANCH CIRCUIT BREAKER PANELBOARD MAIN, MACHINERY DISCONNECT, INDUSTRIAL CONTROL SERIES LPJ MODEL
$