Contoured Wing
Channel, Strut & Fittings
View:
Active Filters :
Part #:GE CL00A310TJ
- NON-REVERSING TYPE UL 508, UL (CANADA AND US), CSA C22.2, CE, SETI, RINA APPROVAL 35 MM DIN RAIL/SCREW FRONT/SIDE MOUNT MOUNTING NEMA 1 ENCLOSURE 9 AMPERE AT 440 V 50/60 HZ (AC-3), 25 AMPERE (AC-1) CURRENT RATING 3 POLE(S) IEC, NEMA CONSTRUCTION STANDARD 110 VAC AT 50 HZ, 125 VAC AT 60 HZ COIL VOLTAGE 1NO AUXILIARY CONTACT 3 HP AT 220/230 V, 5.5 HP AT 380/400/415/440 V, 7.5 HP AT 500 V, 2.2 KW AT 220/230 V, 4 KW AT 380/400/415/440 V, 5.5 KW AT 500 V POWER RATING/VOLTAGE APPLICABLE STANDARD IEC/EN 60947-1, IEC/EN 60947-4-1, IEC/EN 60947-5-1, EN 50005, VDE 0660, VDE 102 OPERATING TEMPERATURE -13 TO 131 DEG F MAXIMUM AUXILIARY CONTACTS 4 DEGREE OF PROTECTION IP20/IP10 CL MODEL
$
91.00
Qty:
Part #:GE CL01A310TJ
- NON-REVERSING TYPE UL 508, UL (CANADA AND US), CSA C22.2, CE, SETI, RINA APPROVAL 35 MM DIN RAIL/SCREW FRONT/SIDE MOUNT MOUNTING NEMA 1 ENCLOSURE 12 AMPERE AT 440 V 50/60 HZ (AC-3), 25 AMPERE (AC-1) CURRENT RATING 3 POLE(S) IEC, NEMA CONSTRUCTION STANDARD 110 VAC AT 50 HZ COIL VOLTAGE 1NO AUXILIARY CONTACT 4 HP AT 220/230 V, 7.5 HP AT 380/400/415/440 V, 10 HP AT 500 V, 3 KW AT 220/230 V, 5.5 KW AT 380/400/415/440 V, 7.5 KW AT 500 V POWER RATING/VOLTAGE APPLICABLE STANDARD IEC/EN 60947-1, IEC/EN 60947-4-1, IEC/EN 60947-5-1, EN 50005, VDE 0660, VDE 102 OPERATING TEMPERATURE -13 TO 131 DEG F MAXIMUM AUXILIARY CONTACTS 4 DEGREE OF PROTECTION IP20/IP10 CL MODEL
$
109.00
Qty:
Part #:GE CL02A310TJ
- NON-REVERSING TYPE UL 508, UL (CANADA AND US), CSA C22.2, CE, SETI, RINA APPROVAL 35 MM DIN RAIL/SCREW FRONT/SIDE MOUNT MOUNTING NEMA 1 ENCLOSURE 18 AMPERE AT 440 V 50/60 HZ (AC-3), 32 AMPERE (AC-1) CURRENT RATING 3 POLE(S) IEC, NEMA CONSTRUCTION STANDARD 110 VAC AT 50 HZ, 125 VAC AT 60 HZ COIL VOLTAGE 1NO AUXILIARY CONTACT 5.5 HP AT 220/230 V, 10 HP AT 380/400/415/440 V, 13.5 HP AT 500 V, 4 KW AT 220/230 V, 7.5 KW AT 380/400/415/440 V, 10 KW AT 500 V POWER RATING/VOLTAGE APPLICABLE STANDARD IEC/EN 60947-1, IEC/EN 60947-4-1, IEC/EN 60947-5-1, EN 50005, VDE 0660, VDE 102 OPERATING TEMPERATURE -13 TO 131 DEG F MAXIMUM AUXILIARY CONTACTS 4 DEGREE OF PROTECTION IP20/IP10 CL MODEL
$
124.00
Qty:
closeout
Part #:GE CL00D310TD
- CLOSEOUTS Only 1 Left!
- NON-REVERSING TYPE UL 508, UL (CANADA AND US), CSA C22.2, CE, SETI, RINA APPROVAL 35 MM DIN RAIL/SCREW FRONT/SIDE MOUNT MOUNTING NEMA 1 ENCLOSURE 9 AMPERE AT 440 V 50/60 HZ (AC-3), 25 AMPERE (AC-1) CURRENT RATING 3 POLE(S) IEC, NEMA CONSTRUCTION STANDARD 24 VDC COIL VOLTAGE 1NO AUXILIARY CONTACT 3 HP AT 220/230 V, 5.5 HP AT 380/400/415/440 V, 7.5 HP AT 500 V, 2.2 KW AT 220/230 V, 4 KW AT 380/400/415/440 V, 5.5 KW AT 500 V POWER RATING/VOLTAGE APPLICABLE STANDARD IEC/EN 60947-1, IEC/EN 60947-4-1, IEC/EN 60947-5-1, EN 50005, VDE 0660, VDE 102 OPERATING TEMPERATURE -13 TO 131 DEG F MAXIMUM AUXILIARY CONTACTS 4 DEGREE OF PROTECTION IP20/IP10 CL MODEL
$
109.00
Qty:
Part #:GE CL01D310TD
- NON-REVERSING TYPE UL 508, UL (CANADA AND US), CSA C22.2, CE, SETI, RINA APPROVAL 35 MM DIN RAIL/SCREW FRONT/SIDE MOUNT MOUNTING NEMA 1 ENCLOSURE 12 AMPERE AT 440 V 50/60 HZ (AC-3), 25 AMPERE (AC-1) CURRENT RATING 3 POLE(S) IEC, NEMA CONSTRUCTION STANDARD 24 VDC COIL VOLTAGE 1NO AUXILIARY CONTACT 4 HP AT 220/230 V, 7.5 HP AT 380/400/415/440 V, 10 HP AT 500 V, 3 KW AT 220/230 V, 5.5 KW AT 380/400/415/440 V, 7.5 KW AT 500 V POWER RATING/VOLTAGE APPLICABLE STANDARD IEC/EN 60947-1, IEC/EN 60947-4-1, IEC/EN 60947-5-1, EN 50005, VDE 0660, VDE 102 OPERATING TEMPERATURE -13 TO 131 DEG F MAXIMUM AUXILIARY CONTACTS 4 DEGREE OF PROTECTION IP20/IP10 CL MODEL
$
133.00
Qty:
Part #:GE CL02D310TD
- NON-REVERSING TYPE UL 508, UL (CANADA AND US), CSA C22.2, CE, SETI, RINA APPROVAL 35 MM DIN RAIL/SCREW FRONT/SIDE MOUNT MOUNTING NEMA 1 ENCLOSURE 18 AMPERE AT 440 V 50/60 HZ (AC-3), 32 AMPERE (AC-1) CURRENT RATING 3 POLE(S) IEC, NEMA CONSTRUCTION STANDARD 24 VDC COIL VOLTAGE 1NO AUXILIARY CONTACT 5.5 HP AT 220/230 V, 10 HP AT 380/400/415/440 V, 13.5 HP AT 500 V, 4 KW AT 220/230 V, 7.5 KW AT 380/400/415/440 V, 10 KW AT 500 V POWER RATING/VOLTAGE APPLICABLE STANDARD IEC/EN 60947-1, IEC/EN 60947-4-1, IEC/EN 60947-5-1, EN 50005, VDE 0660, VDE 102 OPERATING TEMPERATURE -13 TO 131 DEG F MAXIMUM AUXILIARY CONTACTS 4 DEGREE OF PROTECTION IP20/IP10
$
147.00
Qty:
Part #:GE CL25A310TJ
- NON-REVERSING TYPE UL 508, CSA C22.2, CE APPROVAL 35 MM DIN RAIL/SCREW FRONT MOUNT MOUNTING 32 AMPERE (UL CONTINUOUS), 45 AMPERE (IEC AC-1) CURRENT RATING 3 POLE(S) IEC CONSTRUCTION STANDARD 110 VAC AT 50 HZ, 120 VAC AT 60 HZ COIL VOLTAGE 1NO AUXILIARY CONTACT 1.5 HP AT 115 V 60 HZ, 3 HP AT 230 V 60 HZ 1-PHASE, 5 HP AT 200 V 60 HZ, 7.5 HP AT 230 V 60 HZ, 15 HP AT 460/575 V 60 HZ 3-PHASE, 11 KW AT 380/415 V 50 HZ POWER RATING/VOLTAGE APPLICABLE STANDARD IEC 947-1, IEC 947-4, EN 50005, VDE 0660, VDE 102 OPERATING TEMPERATURE -13 TO 131 DEG F MAXIMUM AUXILIARY CONTACTS 4 APPLICATION MOTOR LOAD AND DUTY CYCLE CL MODEL
$
138.00
Qty:
Part #:3M 33+SUPER-3/4X66FT
- INSULATING, JACKETING, HARNESSING TYPE PVC TAPE, RUBBER RESIN ADHESIVE MATERIAL BLACK FINISH 66 FOOT 3/4 INCH UL 510, CSA C22.2 APPROVAL LOW AND HIGH VOLTAGE BUS, PROTECTIVE JACKETING AND HARNESSING, INDOOR, OUTDOOR APPLICATION 600 VOLT VOLTAGE RATING 7 MIL THICKNESS 0 TO 221 DEG F TEMPERATURE RATING 1150 VOLT PER MIL DIELECTRIC STRENGTH SCOTCH[R], SUPER 33+[TM] BRAND ROHS COMPLIANT BACKING STRENGTH 15 POUND PER INCH APPLICABLE STANDARD A-A-55809 33 MODEL
$
11.46
Qty:
closeout
$
1.96
Qty:
$
4.46
Qty:
closeout
$
4.60
Qty:
Part #:STL-CTY RC-1
- RIGHT ANGLE TYPE MALLEABLE IRON MATERIAL GALVANIZED FINISH CSA APPROVAL 100 PER CARTON STANDARD PACKAGE 1 INCH TRADE SIZE 1 INCH CONDUIT SIZE IBERVILLE[R] BRAND RC MODEL
Part #:S-STRUT A1200HS-10
- METAL FRAMING, SINGLE TYPE STRIP STEEL MATERIAL GOLDGALV FINISH 10 FT 1.625 INCH 1.625 INCH SLOTTED CONFIGURATION 12 GAUGE THICKNESS COLD FORMED HOT ROLLED PICKLED PROCESS 2 INCH CENTER SPACING 1 CHANNEL(S) 9/16 INCH L X 1-1/8 INCH W HOLE/SLOT SIZE 0.557 SQ INCH CROSS SECTION AREA
Part #:S-STRUT B1400HS-10
- METAL FRAMING, SINGLE TYPE STRIP STEEL MATERIAL GOLDGALV FINISH 10 FT 1.625 INCH 0.813 INCH SLOTTED CONFIGURATION 14 GAUGE THICKNESS COLD FORMED HOT ROLLED PICKLED PROCESS 2 INCH CENTER SPACING 1 CHANNEL(S) 9/16 INCH L X 1-1/8 INCH W HOLE/SLOT SIZE 0.28 SQ INCH CROSS SECTION AREA SUPERSTRUT[R] BRAND
Part #:S-STRUT A100-1/4
- WITH SPRING TYPE GRADE 2 MILD STEEL MATERIAL SILVERGALV/ELECTROGALVANIZED FINISH 1/4 INCH NOMINAL DIAMETER UNC-2A THREAD SERIES 20 TPI CASE HARDENED PROCESS OVERALL DIMENSION 1.338 INCH WIDTH X 0.238 INCH HEIGHT USED ON A/C SERIES CHANNEL AND INSERT
Part #:S-STRUT A100-3/8
- WITH SPRING TYPE MILD STEEL MATERIAL GOLD GALVANIZED FINISH 3/8 INCH NOMINAL DIAMETER 16 TPI CASE HARDENED PROCESS SUPERSTRUT. BRAND USED ON A/C SERIES CHANNEL AND INSERT 100 MODEL
Part #:S-STRUT A100-5/16
- WITH SPRING TYPE GRADE 2 MILD STEEL MATERIAL SILVERGALV/ELECTROGALVANIZED FINISH 5/16 INCH NOMINAL DIAMETER UNC-2A THREAD SERIES 18 TPI CASE HARDENED PROCESS OVERALL DIMENSION 1.338 INCH WIDTH X 0.358 INCH HEIGHT USED ON A/C SERIES CHANNEL AND INSERT
Part #:STL-CTY C105-1
- 2-PIECE TYPE GALV-KROM FINISH CSA APPLICABLE STANDARD 14 GAUGE THICKNESS 750 LB LOAD RATING CHANNEL MOUNT MOUNTING TYPE 1 INCH PIPE SIZE STEEL CLAMP MATERIAL 1 NUMBER OF SCREW/BOLTS USED ON RIGID CONDUIT AND PIPE OUTER DIAMETER 1.315 INCH C105 MODEL
Part #:STL-CTY C105-1-1/2
- 2-PIECE TYPE GALV-KROM FINISH CSA APPLICABLE STANDARD 12 GAUGE THICKNESS 800 LB LOAD RATING CHANNEL MOUNT MOUNTING TYPE 1-1/2 INCH PIPE SIZE STEEL CLAMP MATERIAL 1 NUMBER OF SCREW/BOLTS USED ON RIGID CONDUIT AND PIPE OUTER DIAMETER 1.9 INCH C105 MODEL
Part #:STL-CTY C105-1/2
- 2-PIECE TYPE GALV-KROM FINISH CSA APPLICABLE STANDARD 14 GAUGE THICKNESS 750 LB LOAD RATING CHANNEL MOUNT MOUNTING TYPE 1/2 INCH PIPE SIZE STEEL CLAMP MATERIAL 1 NUMBER OF SCREW/BOLTS USED ON RIGID CONDUIT AND PIPE OUTER DIAMETER 0.84 INCH C105 MODEL
Part #:STL-CTY C105-3/4
- 2-PIECE TYPE GALV-KROM FINISH CSA APPLICABLE STANDARD 14 GAUGE THICKNESS 750 LB LOAD RATING CHANNEL MOUNT MOUNTING TYPE 3/4 INCH PIPE SIZE STEEL CLAMP MATERIAL 1 NUMBER OF SCREW/BOLTS USED ON RIGID CONDUIT AND PIPE OUTER DIAMETER 3.5 INCH SERIES C105 MODEL
Part #:STL-CTY C106-1-1/4
- 2-PIECE TYPE GALV-KROM FINISH CSA APPLICABLE STANDARD 14 GAUGE THICKNESS 750 LB LOAD RATING CHANNEL MOUNT MOUNTING TYPE 1-1/4 INCH PIPE SIZE STEEL CLAMP MATERIAL 1 NUMBER OF SCREW/BOLTS USED ON RIGID CONDUIT AND PIPE OUTER DIAMETER 1.51 INCH C106 MODEL
Part #:DOTTIE RC2
- STRAIGHT TYPE STEEL MATERIAL ZINC PLATED FINISH 1-1/8 3/8 NOMINAL DIAMETER PACKAGING QUANTITY 50, 500 PER MASTER CARTON WARRANTY 90 DAYS FROM DATE OF PURCHASE RC MODEL
$
0.82
Qty:
Part #:S-STRUT AB205
- CORNER TYPE CARBON STEEL MATERIAL 3-1/2 INCH LENGTH X 1-5/8 INCH WIDTH X 4-1/8 INCH HEIGHT SIZE GOLDGALV FINISH 1-5/8 INCH CHANNEL WIDTH 1/4 INCH THICKNESS HOT ROLLED PROCESS 74.5 POUND PER 100 WEIGHT 4 HOLE(S) 9/16 INCH DIAMETER HOLE/SLOT SIZE 2 SIDE(S) END TO HOLE CENTER SIZE 13/16 INCH HOLE SPACING ON CENTER SIZE 1-7/8 INCH 200 MODEL
Displaying: 1 - 24 of 63 Matching Items