Part #:BUSS FRN-R-125

CLASS RK5 TYPE 7.13 INCH UL 248-12, CSA C22.2, CE APPROVAL 250 VOLT AC, 125 VOLT DC VOLTAGE RATING 1.56 INCH DIAMETER 200 KILOAMP SYMMETRICAL (AC), 20 KILOAMP (DC) INTERRUPTING RATING 125 AMP CURRENT RATING BLADE TERMINAL TYPE 10 SECOND TIME DELAY AT 500 PERCENT RATED LOAD, DUAL ELEMENT, NON-INDICATING CHARACTERISTICS FUSETRON[TM] BRAND APPLICATION POWER PANELBOARD, MOTOR CONTROL CENTER, COMBINATION STARTER, MACHINERY DISCONNECT FRN-R MODEL
$ 229.84
Part #:BUSS FRS-R-300

CLASS RK5 TYPE 11.63 INCH UL 248-12, CSA C22.2, CE APPROVAL 600 VOLT AC, 300 VOLT DC VOLTAGE RATING 2.34 INCH DIAMETER 200 KILOAMP SYMMETRICAL (AC), 20 KILOAMP (DC) INTERRUPTING RATING 300 AMP CURRENT RATING BLADE TERMINAL TYPE 10 SECOND TIME DELAY AT 500 PERCENT RATED LOAD, DUAL ELEMENT, NON-INDICATING CHARACTERISTICS FUSETRON[TM] BRAND APPLICATION POWER PANELBOARD, MOTOR CONTROL CENTER, COMBINATION STARTER, MACHINERY DISCONNECT FRS-R MODEL
$ 707.80
Part #:BUSS FRN-R-15

CLASS RK5 TYPE 2 INCH UL 248-12, CSA C22.2, CE APPROVAL 250 VAC/125 VDC VOLTAGE RATING 0.56 INCH DIAMETER 200 KILOAMPERE (SYMMETRICAL), 20 KILOAMPERE (DC) INTERRUPTING RATING 15 AMPERE CURRENT RATING FERRULE WITH GROOVED RING TERMINAL TYPE 10 SEC TIME DELAY (AT 500 PERCENT RATED LOAD), DUAL ELEMENT, NON-INDICATING CHARACTERISTICS FUSETRON[TM] BRAND APPLICATION POWER PANELBOARD, MOTOR CONTROL CENTER, COMBINATION STARTER, MACHINERY DISCONNECT SERIES FRN-R MODEL
$ 24.08
Part #:BUSS FRN-R-40

CLASS RK5 TYPE 3 INCH UL 248-12, CSA C22.2, CE APPROVAL 250 VAC/125 VDC VOLTAGE RATING 0.81 INCH DIAMETER 200 KILOAMPERE (SYMMETRICAL), 20 KILOAMPERE (DC) INTERRUPTING RATING 40 AMPERE CURRENT RATING FERRULE WITH GROOVED RING TERMINAL TYPE 10 SEC TIME DELAY (AT 500 PERCENT RATED LOAD), DUAL ELEMENT, NON-INDICATING CHARACTERISTICS FUSETRON[TM] BRAND APPLICATION POWER PANELBOARD, MOTOR CONTROL CENTER, COMBINATION STARTER, MACHINERY DISCONNECT SERIES FRN-R MODEL
$ 39.88
Part #:BUSS FRN-R-45

CLASS RK5 TYPE 3 INCH UL 248-12, CSA C22.2, CE APPROVAL 250 VOLT AC, 125 VOLT DC VOLTAGE RATING 0.81 INCH DIAMETER 200 KILOAMP SYMMETRICAL (AC), 20 KILOAMP (DC) INTERRUPTING RATING 45 AMP CURRENT RATING BLADE TERMINAL TYPE 10 SECOND TIME DELAY AT 500 PERCENT RATED LOAD, DUAL ELEMENT, NON-INDICATING CHARACTERISTICS FUSETRON[TM] BRAND APPLICATION POWER PANELBOARD, MOTOR CONTROL CENTER, COMBINATION STARTER, MACHINERY DISCONNECT FRN-R MODEL
$ 39.88
Part #:BUSS FRN-R-50

CLASS RK5 TYPE 3 INCH UL 248-12, CSA C22.2, CE APPROVAL 250 VOLT AC, 125 VOLT DC VOLTAGE RATING 0.81 INCH DIAMETER 200 KILOAMP SYMMETRICAL (AC), 20 KILOAMP (DC) INTERRUPTING RATING 50 AMP CURRENT RATING BLADE TERMINAL TYPE 10 SECOND TIME DELAY AT 500 PERCENT RATED LOAD, DUAL ELEMENT, NON-INDICATING CHARACTERISTICS FUSETRON[TM] BRAND APPLICATION POWER PANELBOARD, MOTOR CONTROL CENTER, COMBINATION STARTER, MACHINERY DISCONNECT FRN-R MODEL
$ 39.88
Part #:BUSS FRN-R-60

CLASS RK5 TYPE 3 INCH UL 248-12, CSA C22.2, CE APPROVAL 250 VAC/125 VDC VOLTAGE RATING 0.81 INCH DIAMETER 200 KILOAMPERE (SYMMETRICAL), 20 KILOAMPERE (DC) INTERRUPTING RATING 60 AMPERE CURRENT RATING FERRULE WITH GROOVED RING TERMINAL TYPE 10 SEC TIME DELAY (AT 500 PERCENT RATED LOAD), DUAL ELEMENT, NON-INDICATING CHARACTERISTICS FUSETRON[TM] BRAND APPLICATION POWER PANELBOARD, MOTOR CONTROL CENTER, COMBINATION STARTER, MACHINERY DISCONNECT SERIES FRN-R MODEL
$ 39.88
Part #:BUSS FRN-R-5

CLASS RK5 TYPE 2 INCH UL 248-12, CSA C22.2, CE APPROVAL 250 VOLT AC, 125 VOLT DC VOLTAGE RATING 0.56 INCH DIAMETER 200 KILOAMP SYMMETRICAL (AC), 20 KILOAMP (DC) INTERRUPTING RATING 5 AMP CURRENT RATING BLADE TERMINAL TYPE 8 SECOND TIME DELAY AT 500 PERCENT RATED LOAD, DUAL ELEMENT, NON-INDICATING CHARACTERISTICS FUSETRON[TM] BRAND APPLICATION POWER PANELBOARD, MOTOR CONTROL CENTER, COMBINATION STARTER, MACHINERY DISCONNECT FRN-R MODEL
$ 37.98
Part #:BUSS FRN-R-70

CLASS RK5 TYPE 5.88 INCH UL 248-12, CSA C22.2, CE APPROVAL 250 VAC VOLTAGE RATING 1.06 INCH DIAMETER 200 KILOAMPERE (SYMMETRICAL), 20 KILOAMPERE (DC) INTERRUPTING RATING 70 AMPERE CURRENT RATING BLADE TERMINAL TYPE 10 SEC TIME DELAY (AT 500 PERCENT RATED LOAD), DUAL ELEMENT CHARACTERISTICS FUSETRON[TM] BRAND APPLICATION POWER PANELBOARD, MOTOR CONTROL CENTER, COMBINATION STARTER, MACHINERY DISCONNECT SERIES FRN-R MODEL
$ 94.00
Part #:BUSS FRN-R-90

CLASS RK5 TYPE 5.88 INCH UL 248-12, CSA C22.2, CE APPROVAL 250 VOLT AC, 125 VOLT DC VOLTAGE RATING 1.06 INCH DIAMETER 200 KILOAMP SYMMETRICAL (AC), 20 KILOAMP (DC) INTERRUPTING RATING 90 AMP CURRENT RATING BLADE TERMINAL TYPE 10 SECOND TIME DELAY AT 500 PERCENT RATED LOAD, DUAL ELEMENT, NON-INDICATING CHARACTERISTICS FUSETRON[TM] BRAND APPLICATION POWER PANELBOARD, MOTOR CONTROL CENTER, COMBINATION STARTER, MACHINERY DISCONNECT FRN-R MODEL
$ 94.00
Part #:BUSS FRS-R-3

CLASS RK5 TYPE 5 INCH UL 248-12, CSA C22.2, CE APPROVAL 600 VAC/300 VDC VOLTAGE RATING 0.81 INCH DIAMETER 200 KILOAMPERE (SYMMETRICAL), 20 KILOAMPERE (DC) INTERRUPTING RATING 3 AMPERE CURRENT RATING FERRULE WITH GROOVED RING TERMINAL TYPE 10 SEC TIME DELAY (AT 500 PERCENT RATED LOAD), DUAL ELEMENT, NON-INDICATING CHARACTERISTICS FUSETRON[TM] BRAND APPLICATION POWER PANELBOARD, MOTOR CONTROL CENTER, COMBINATION STARTER, MACHINERY DISCONNECT SERIES FRS-R MODEL
$ 53.46
Part #:BUSS FRS-R-5

CLASS RK5 TYPE 5 INCH UL 248-12, CSA C22.2, CE APPROVAL 600 VOLT AC, 300 VOLT DC VOLTAGE RATING 0.81 INCH DIAMETER 200 KILOAMP SYMMETRICAL (AC), 20 KILOAMP (DC) INTERRUPTING RATING 5 AMP CURRENT RATING FERRULE WITH GROOVED RING TERMINAL TYPE 10 SECOND TIME DELAY AT 500 PERCENT RATED LOAD, DUAL ELEMENT, NON-INDICATING CHARACTERISTICS FUSETRON[TM] BRAND APPLICATION POWER PANELBOARD, MOTOR CONTROL CENTER, COMBINATION STARTER, MACHINERY DISCONNECT FRS-R MODEL
$ 53.46
Part #:BUSS FRS-R-8

CLASS RK5 TYPE 5 INCH UL 248-12, CSA C22.2, CE APPROVAL 600 VAC/300 VDC VOLTAGE RATING 0.81 INCH DIAMETER 200 KILOAMPERE (SYMMETRICAL), 20 KILOAMPERE (DC) INTERRUPTING RATING 8 AMPERE CURRENT RATING FERRULE WITH GROOVED RING TERMINAL TYPE 10 SEC TIME DELAY (AT 500 PERCENT RATED LOAD), DUAL ELEMENT, NON-INDICATING CHARACTERISTICS FUSETRON[TM] BRAND APPLICATION POWER PANELBOARD, MOTOR CONTROL CENTER, COMBINATION STARTER, MACHINERY DISCONNECT SERIES FRS-R MODEL
$ 53.46
Part #:BUSS FRS-R-35

CLASS RK5 TYPE 5.5 INCH UL 248-12, CSA C22.2, CE APPROVAL 600 VOLT AC, 250 VOLT DC VOLTAGE RATING 1.06 INCH DIAMETER 200 KILOAMP SYMMETRICAL (AC), 20 KILOAMP (DC) INTERRUPTING RATING 35 AMP CURRENT RATING FERRULE WITH GROOVED RING TERMINAL TYPE 10 SECOND TIME DELAY AT 500 PERCENT RATED LOAD, DUAL ELEMENT, NON-INDICATING CHARACTERISTICS FUSETRON[TM] BRAND APPLICATION POWER PANELBOARD, MOTOR CONTROL CENTER, COMBINATION STARTER, MACHINERY DISCONNECT FRS-R MODEL
$ 81.60
Part #:BUSS FRS-R-50

CLASS RK5 TYPE 5.5 INCH UL 248-12, CSA C22.2, CE APPROVAL 600 VOLT AC, 250 VOLT DC VOLTAGE RATING 1.06 INCH DIAMETER 200 KILOAMP SYMMETRICAL (AC), 20 KILOAMP (DC) INTERRUPTING RATING 50 AMP CURRENT RATING FERRULE WITH GROOVED RING TERMINAL TYPE 10 SECOND TIME DELAY AT 500 PERCENT RATED LOAD, DUAL ELEMENT, NON-INDICATING CHARACTERISTICS FUSETRON[TM] BRAND APPLICATION POWER PANELBOARD, MOTOR CONTROL CENTER, COMBINATION STARTER, MACHINERY DISCONNECT FRS-R MODEL
$ 81.60
Part #:BUSS FRS-R-250

CLASS RK5 TYPE 11.63 INCH UL 248-12, CSA C22.2, CE APPROVAL 600 VAC/300 VDC VOLTAGE RATING 2.59 INCH DIAMETER 200 KILOAMPERE (SYMMETRICAL), 20 KILOAMPERE (DC) INTERRUPTING RATING 250 AMPERE CURRENT RATING BLADE TERMINAL TYPE 10 SEC TIME DELAY (AT 500 PERCENT RATED LOAD), DUAL ELEMENT CHARACTERISTICS FUSETRON[TM] BRAND APPLICATION POWER PANELBOARD, MOTOR CONTROL CENTER, COMBINATION STARTER, MACHINERY DISCONNECT SERIES FRS-R MODEL
$ 707.80
Part #:PAND SCS500-6

BUTT TYPE 2.87 INCH 0.84 INCH INNER DIAMETER 1.05 INCH OUTER DIAMETER COPPER CONDUCTOR MATERIAL UL, CSA APPROVAL 35 KV VOLTAGE RATING TIN PLATED COPPER BODY MATERIAL 500 KCMIL CONDUCTOR SIZE BROWN COLOR CODE STANDARD BARREL TYPE TEMPERATURE RATING 90 DEG C ROHS COMPLIANT SCS MODEL
$ 21.99
Part #:PAND SCL500-6

BUTT TYPE COPPER MATERIAL BROWN COLOR 4.62 INCH 4.62 LENGTH IN INCH UL 486-A, CSA APPROVAL 35 KV VOLTAGE RATING 6 STANDARD PACKAGE 350 MCM (COPPER WELD), 500 MCM (COPPER), 925/24 (LOCOMOTIVE) CONDUCTOR SIZE 0.84 INCH BARREL INNER DIAMETER 1.06 INCH BARREL OUTER DIAMETER PANDUIT[R] BRAND LENGTH IN INCH - UOM IN SCL MODEL
$ 24.18
Part #:GE TCAL29

LUG TYPE SFH/SFL/SFP/TFJ/TFK/THFK/SF250 SPECTRA SERIES MOLDED CASE CIRCUIT BREAKER USED ON 250 AMP MAX. BREAKER CURRENT RATING 8 AWG MIN. CONDUCTOR SIZE 350 KCMIL MAX. CONDUCTOR SIZE COPPER/ALUMINUM CONDUCTOR MATERIAL 1 CONDUCTOR(S) PLATED EXTRUDED ALUMINUM BODY MATERIAL 1 QUANTITY
$ 13.00
Part #:KLEIN 56028

Bright, focused flashlight and broadcasting work light in one tool Strong magnet for secure, hands-free illumination Glow ring tip charges while the light is on and allows for easy retrieval in the dark and in your tool bag Waterproof (IP67) and dustproof Aluminum body with cushion-grip handle Pocket clip for easy, convenient access
$ 42.06
Part #:DOTTIE UT8D

NON-DETECTABLE TYPE POLYETHYLENE MATERIAL 1000 FOOT 3 INCH 4 MIL THICKNESS 12 PER CARTON STANDARD PACKAGE CAUTION BURIED ELECTRIC LINE BELOW LEGEND BLACK LEGEND COLOR RED TAPE COLOR LEAD-FREE PC 5320 MODEL
$ 62.34
Part #:BUR SP14BG25

BUTT TYPE ELECTROLYTIC TIN PLATED COPPER MATERIAL BLUE COLOR UL 467, CSA APPROVAL 25 STANDARD PACKAGE 16 TO 10 AWG SOLID/STRANDED (COPPER) CONDUCTOR SIZE VINYL INSULATED INSULATION TYPE ROHS COMPATIBLE
$ 9.00
Part #:BUR SP18BG25

BUTT TYPE ELECTROLYTIC TIN PLATED COPPER MATERIAL UL 467, CSA APPROVAL 25 STANDARD PACKAGE 20 TO 18 AWG STRANDED (COPPER) CONDUCTOR SIZE VINYL INSULATED INSULATION TYPE ROHS COMPATIBLE