Generators
All in One Controllers


Displaying: 217 - 235 of 235 Matching Items
235 Items
View:
Active Filters :
Part #:CRL 76512.18.06
MTW/TFF/AWM (UL), TEW (CSA) TYPE 2000 FT 2000 LENGTH IN FT 0.123 INCH OUTER DIAMETER ASTM B-8 ANNEALED BARE COPPER CONDUCTOR MATERIAL UL, CSA APPROVAL 600 V VOLTAGE RATING -40 TO 90 DEG C (MTW/TFF), -20 TO 105 DEG C (AWM/TEW) TEMPERATURE RATING 14 LB/MFT WEIGHT PVC INSULATION MATERIAL 16 AWG CONDUCTOR SIZE GREEN COLOR CODE 26/30 STRANDS STRANDING CAROL[R] BRAND LENGTH IN FT - UOM FT
$ 0.23 M
Qty:
add to cart
Part #:CRL 76512.18.07
MTW/TFF/AWM (UL), TEW (CSA) TYPE 2000 FT 2000 LENGTH IN FT 0.123 INCH OUTER DIAMETER ASTM B-8 ANNEALED BARE COPPER CONDUCTOR MATERIAL UL, CSA APPROVAL 600 V VOLTAGE RATING -40 TO 90 DEG C (MTW/TFF), -20 TO 105 DEG C (AWM/TEW) TEMPERATURE RATING 14 LB/MFT WEIGHT PVC INSULATION MATERIAL 16 AWG CONDUCTOR SIZE BLUE COLOR CODE 26/30 STRANDS STRANDING CAROL[R] BRAND LENGTH IN FT - UOM FT
$ 0.25 FT
Qty:
add to cart
Part #:MTW 16BN500
16 AWG MTW/UL1015 Hook-Up Stranded Wire, 600V 16 AWG UL1015 Type conductors are primarily used in control cabinets, in machine tool applications and appliance wiring applications. Applications requiring Type MTW conductor is appropriate for use in dry locations at 90&degC, or not to exceed 60&degC in wet locations or where exposed to oils or coolants. Applications requiring Type AWM conductor is appropriate for use at temperatures to not exceed 105&degC in dry locations.ConductorBare Copper InsulationPolyvinyl Chloride (PVC)StandardsUL recognized AWM Style 1015 per 758. Passes VW-1 vertical flame test. CSA TEW or AWM Specifications Size16 AWGNumber of Strands26Temp105&degCInsulation Thickness0.031 inchesOutside Diameter0.124 inchesWeight0.014 lbs per ftVoltage600V
$ 0.12 M
Qty:
add to cart
Part #:CRL 76812.R8.01
MTW/TFF/AWM (UL), TEW (CSA) TYPE 500 FT 500 LENGTH IN FT 0.136 INCH OUTER DIAMETER ANNEALED STRANDED BARE COPPER CONDUCTOR MATERIAL UL, CSA APPROVAL 600 V VOLTAGE RATING 20 LB/MFT WEIGHT PVC INSULATION MATERIAL 14 AWG CONDUCTOR SIZE SPOOL PACKAGE TYPE 19/0.0159 STRANDS STRANDING CAROL[R] BRAND LENGTH IN FT - UOM FT
$ 0.34 FT
Qty:
add to cart
Part #:CRL 76812.R8.03
MTW/TFF/AWM (UL), TEW (CSA) TYPE 500 FT 500 LENGTH IN FT 0.136 INCH OUTER DIAMETER ANNEALED STRANDED BARE COPPER CONDUCTOR MATERIAL UL, CSA APPROVAL 600 V VOLTAGE RATING 20 LB/MFT WEIGHT PVC INSULATION MATERIAL 14 AWG CONDUCTOR SIZE SPOOL PACKAGE TYPE 19/0.0159 STRANDS STRANDING CAROL[R] BRAND LENGTH IN FT - UOM FT
$ 0.44 M
Qty:
add to cart
Part #:CRL 76822.R8.01
MTW/TFF/AWM (UL), TEW (CSA) TYPE 500 FT 500 LENGTH IN FT 0.155 INCH OUTER DIAMETER ANNEALED BARE COPPER CONDUCTOR MATERIAL UL, CSA APPROVAL 600 V VOLTAGE RATING -40 TO 90 DEG C (UL MTW), -20 TO 105 DEG C (UL AWM/CSA TEW) TEMPERATURE RATING 28 LB/MFT WEIGHT PVC INSULATION MATERIAL 12 AWG CONDUCTOR SIZE PVC JACKET MATERIAL SPOOL PACKAGE TYPE 19/0.0185 STRANDS STRANDING BLACK JACKET COLOR CAROL[R] BRAND INSULATION THICKNESS 0.031 INCH LENGTH IN FT - UOM FT
$ 0.48 FT
Qty:
add to cart
Part #:MTW 12WE2500
12 AWG MTW Stranded Wire, 600V. Type conductors are primarily used in control cabinets, in machine tool applications and appliance wiring applications. Applications requiring Type MTW conductor is appropriate for use in dry locations at 90&degC, or not to exceed 60&degC in wet locations or where exposed to oils or coolants. Applications requiring Type AWM conductor is appropriate for use at temperatures to not exceed 105&degC in dry locations. E315270 12 AWG (UL) MTW OR THHW OR BC-5W2 OR AWM 1011/1015/1230/1335 600V OR 1032/10269 1000V, VW-1---240954 CSA TEW 600V OR AWM 1 A/B 105C 1000V FT-1---SAE J1128 TYPE GPT Specifications Size12 AWGNumber of Strands19 or 65Temp105&degCInsulation Thickness0.030 inchesOutside Diameter0.151 inchesVoltage600V
$ 0.51 M
Qty:
add to cart
Part #:MTW 12BK2500
10 AWG MTW Stranded Wire, 600V Type conductors are primarily used in control cabinets, in machine tool applications and appliance wiring applications. Applications requiring Type MTW conductor is appropriate for use in dry locations at 90&degC, or not to exceed 60&degC in wet locations or where exposed to oils or coolants. Applications requiring Type AWM conductor is appropriate for use at temperatures to not exceed 105&degC in dry locations. E315270 12 AWG (UL) MTW OR THHW OR BC-5W2 OR AWM 1011/1015/1230/1335 600V OR 1032/10269 1000V, VW-1---240954 CSA TEW 600V OR AWM 1 A/B 105C 1000V FT-1---SAE J1128 TYPE GPT Specifications Size10 AWGNumber of Strands19 or 105Temp105&degCInsulation Thickness0.030 inchesOutside Diameter0.205 inchesVoltage600V
$ 0.51 FT
Qty:
add to cart
Part #:BARE S8
Used for residential electrical systems before entering the home, usually at the meter base Used as residential grounding wire Used for overhead transmission and distribution applications
$ 0.69 M
Qty:
add to cart
Part #:TW8 SOLGN
Type TW is suitable for use in conduit or other recognized raceways for services, feeders, and branch-circuit wiring. Suitable for use in wet or dry locations where temperatures do not exceed 75&degC.
$ 1.10 M
Qty:
add to cart
Part #:HOR HE800ADC920
Description MetalSmartStack I/O can only be stacked directly on the back of products supporting metal encased I/O models, such as Classic OCS, RCS, RX ruggedized controller, and Metal FOX. Products are sorted by commonality. All SmartStack I/O modules include spring-clamp style removable terminals except where noted.
$ 1,968.00
Qty:
add to cart
Part #:MC CABLE82WGREENGRN
8-2C Metal Clad (MC) Cable with Ground, Aluminum Armored, Stranded Copper Conductors Metal Clad Cable may be used for branch, feeder and service for distribution in commercial, industrial, and multi-residential construction. They are suitable for installation in motion picture studios, theaters, and places of assembly (100 people or more) per NEC Articles 230.43, 300.22(C), 330, 396, 518, 520, 530 and 645. These cables may be installed in approved raceways and as open runs of cable on a messenger. They may be installed exposed, concealed or in cable tray and may be run in spaces used for environmental air in accordance with NEC Article 300.22(C) ONLY. - Meets UL 83 Thermoplastic Insulated Wires and Cables- Tested to UL 1479 Fire Tests of Through-Penetration Firestops for one, two or three hour fire rated assemblies (for cables up to #2 AWG)- Meets UL 1569 Metal Clad Cables- Meets UL 1581 Reference Standard for Electrical Wires, Cables, and Flexible Cords- Meets UL 2256 Wire and Cable Test Methods- Designated Type MC per NEC Article 330 Specifications Size8 AWGOutside Diameter0.690 inches Ampere Rating THHN55 @ 90&degC
$ 2.73 M
Qty:
add to cart
Part #:MC CABLE83WGREENGRN
8-3C Metal Clad (MC) Cable with Ground, Aluminum Armored, Stranded Copper Conductors Metal Clad Cable may be used for branch, feeder and service for distribution in commercial, industrial, and multi-residential construction. They are suitable for installation in motion picture studios, theaters, and places of assembly (100 people or more) per NEC Articles 230.43, 300.22(C), 330, 396, 518, 520, 530 and 645. These cables may be installed in approved raceways and as open runs of cable on a messenger. They may be installed exposed, concealed or in cable tray and may be run in spaces used for environmental air in accordance with NEC Article 300.22(C) ONLY. - Meets UL 83 Thermoplastic Insulated Wires and Cables- Tested to UL 1479 Fire Tests of Through-Penetration Firestops for one, two or three hour fire rated assemblies (for cables up to #2 AWG)- Meets UL 1569 Metal Clad Cables- Meets UL 1581 Reference Standard for Electrical Wires, Cables, and Flexible Cords- Meets UL 2256 Wire and Cable Test Methods- Designated Type MC per NEC Article 330 Specifications Size8 AWGOutside Diameter0.765 inches Ampere Rating THHN55 @ 90&degC
$ 3.76 M
Qty:
add to cart
Part #:CAT 32PR
The ideal choice for LAN transmission with specified bandwidth up to 16 MHz. These cables are used for voice and data communications and can handle application bandwidths up to 16 MHz. Other uses for these cables include indoor use on customer premises for the interconnection of telephone key systems, PBX and intercom systems. Product is offered for both plenum (CMP) and riser (CMR) applications. Applications &bull 4 Mbps token ring (IEEE 802.5) &bull Analog voice &bull 10 Mbps 10BASE-T Ethernet (IEEE 802.3) &bull Telecommunications closet wiring Features Benefits &bull CMR and CMP constructions use extremely flexible, FR-PVC jacket &bull Easier and less time-consuming installations, no kinking of outer jacket &bull Jacket color options &bull Improves backbone sub-system identification, reduces labor and mistakes &bull Band marked or striped insulated conductors &bull Reduces termination time and improves circuit identification
$ 0.11 M
Qty:
add to cart
Part #:WIRE UF-B-8/2-CU-WG-125CL
UF-B TYPE 125 FT 678 MIL X 302 MIL OUTER DIAMETER ANNEALED SOFT COPPER CONDUCTOR MATERIAL UL 83/493 APPROVAL 600 V VOLTAGE RATING 40 AMPERE CURRENT RATING 90 DEG C TEMPERATURE RATING 222 LB/MFT WEIGHT 2 CONDUCTOR(S) PVC INSULATION MATERIAL WITH GROUND WIRE 8 AWG CONDUCTOR SIZE NYLON JACKET MATERIAL COIL PACKAGE TYPE 7 STRANDS STRANDING 10 AWG GROUND CONDUCTOR SIZE
$ 23.45 FT
Qty:
add to cart
Part #:WIRE SO-18/4-BLK-250SP
SO TYPE 250 FT 250 LENGTH IN FT COPPER CONDUCTOR MATERIAL 600 V VOLTAGE RATING -40 TO 60 DEG C TEMPERATURE RATING 4 CONDUCTOR(S) EPDM RUBBER INSULATION MATERIAL 18 AWG CONDUCTOR SIZE SPOOL PACKAGE TYPE 16 STRANDS STRANDING BLACK JACKET COLOR
$ 1.48 FT
Qty:
add to cart
Part #:WIRE SPT-2-18/2-BRN-250SP
SPT-2 TYPE 250 FT 250 LENGTH IN FT 0.135 INCH X 0.26 INCH OUTER DIAMETER COPPER CONDUCTOR MATERIAL UL 62, CSA APPROVAL LAMP, RADIO, JUKE BOX APPLICATION 300 V VOLTAGE RATING 60 DEG C TEMPERATURE RATING 2 CONDUCTOR(S) PVC INSULATION MATERIAL 18 AWG CONDUCTOR SIZE PVC JACKET MATERIAL SPOOL PACKAGE TYPE 41/34 STRANDS STRANDING BROWN JACKET COLOR
$ 0.34 FT
Qty:
add to cart
Part #:RG6 U1000R
$ 0.08 M
Qty:
add to cart
Part #:HOU DYKE
Secondary underground distribution cables are used to run power from a pad mounted transformer to the service entry or meter of a structure. The cables are rated for installation in underground duct or directly buried in earth. They are offered in single conductor, duplex, triplex, and quadruplex. he cable is rated at 600V for underground secondary distribution not exceeding 90C. It may be directly buried in earth or installed in duct in both wet or dry locations.
$ 7.17 FT
Qty:
add to cart
 
Displaying: 217 - 235 of 235 Matching Items