Generators
All in One Controllers


Displaying: 193 - 216 of 235 Matching Items
235 Items
View:
Active Filters :
Part #:NMB 63WG500R
6-3 W/G NM-B Wire Black Non-metallic sheathed NM-B cable is used in normally dry installations in residential wiring, as branch circuits for outlets, lighting and other residential loads. Its applications are outlined in NEC 2008 and NEC 2011 Article 334. NM-B is rated at 600 volts and although it is rated at a conductor temperature of 90&degC dry , its ampacity is limited to 60&degC according to the NEC 2008 and NEC 2011. It may be fished through masonry or tile walls, where not exposed or subject to excessive moisture or dampness. NM-B cables are LEAD FREE and RoHS compliant. Equivalent to Romex NM-B. StandardsMeets or exceeds all applicable ASTM specificationsUL 83 Thermoplastic Insulated Wires and CablesUL 719 Non-Metallic CablesFederal Specification A-A-59544 and requirements of the NEC.Voltage rating - 600 volts. ConstructionConductorsSolid 14 to 10 AWG annealed soft bare copper per ASTM B3.Stranded 8 AWG and larger annealed soft bare copper per ASTM B3 and B8.InsulationColor coded polyvinyl chloride (PVC) compound with a nylon covering meeting the required thickness of Type THHN. Conductor insulation is rated 90&degC.GroundSoft, bare copper solid per ASTM B3 and stranded per ASTM B3 and B8Sheath30 mil color coded PVC sheath rated 90C is applied over the completed assembly Specifications Size6 AWGNumber of Conductors3PVC Insulation Thickness0.76 mm / 0.029 inchesGround Wire Size10 AWGNylon Thickness0.13 mm / 0.005 inchesNominal Cable Dimensions16.0 mm / 0.62 inchesWeight per foot0.357 lbsAllowable Ampacity55 Amps
$ 4.92 M
Qty:
add to cart
Part #:THHN 6WE500
Southwire Type THHN or THWN-2 conductors are primarily used in conduit and cable trays for services, feeders, and branch circuits in commercial or industrial applications as specified in the 2008 National Electrical Code. When used as Type THHN, or T90 Nylon conductor is suitable for use in dry locations at temperatures not to exceed 90 &degC. When used as Type THWN-2 or TWN75, conductor is suitable for use in wet or dry locations at temperatures not to exceed 90 &degC or not to exceed 75 &degC when exposed to oil or coolant. When used as Type MTW, conductor is suitable for use in wet locations or when exposed to oil or coolant at temperatures not to exceed 60 &degC or dry locations at temperatures not to exceed 90 &degC (with ampacity limited to that for 75 &degC conductor temperature per NFPA 79). Conductor temperatures not to exceed 105 &degC in dry locations when rated AWM and used as appliance wiring material or when used asT90 Nylon. Voltage for all applications is 600 volts.
$ 1.22 M
Qty:
add to cart
Part #:THHN 8GN500
Southwire Type THHN or THWN-2 conductors are primarily used in conduit and cable trays for services, feeders, and branch circuits in commercial or industrial applications as specified in the 2008 National Electrical Code. When used as Type THHN, or T90 Nylon conductor is suitable for use in dry locations at temperatures not to exceed 90 &degC. When used as Type THWN-2 or TWN75, conductor is suitable for use in wet or dry locations at temperatures not to exceed 90 &degC or not to exceed 75 &degC when exposed to oil or coolant. When used as Type MTW, conductor is suitable for use in wet locations or when exposed to oil or coolant at temperatures not to exceed 60 &degC or dry locations at temperatures not to exceed 90 &degC (with ampacity limited to that for 75 &degC conductor temperature per NFPA 79). Conductor temperatures not to exceed 105 &degC in dry locations when rated AWM and used as appliance wiring material or when used asT90 Nylon. Voltage for all applications is 600 volts.
$ 0.92 M
Qty:
add to cart
Part #:GPS 5819
$ 152.26
Qty:
add to cart
Part #:SOU C588
Exceptionally strong design with high-carbon steel core and tip Tough copper coating won't crack or tear Continuous electro-plating process ensures permanent bond
$ 25.08
Qty:
add to cart
Part #:GPS 5939
Generac OHV engine delivers a long life of reliable power Low-oil shutdown safeguards engine from damage Steel fuel tank and hardened steel cradle provide durability
$ 2,453.16
Qty:
add to cart
Part #:CAT 6PVC
$ 0.35 M
Qty:
add to cart
Part #:OMN AF61802
Conductor &bull 7 strand soft drawn tinned copper, Class B per ASTM B8 and B33 Insulation &bull Flame-retardant Ethylene-Propylene-rubber Individual Shield &bull Aluminum/Mylar shielding tape Drain Wire &bull Tinned copper applied helically over core and twisted pairs Overall Shield &bull Aluminum/Mylar shielding tape Jacket &bull Chlorinated Polyethylene (CPE) Ripcord &bull Nylon Applications &bull Process instrumentation applications where resistance to moisture, chemicals, thermal stability, and physical durability are essential. &bull Use in high performance applications where reliability is essential Standards &bull Rated 90&degC wet or dry &bull UL Type TC &bull ICEA S-82-552 - 600 Volts &bull IEEE 1202 (70,000 BTU/hr)/ CSA FT4 &bull ICEA T-29-520-(210,000 BTU/hr) &bull UL Subject 1277 (70,000 BTU/hr) &bull OSHA Acceptable
$ 2.61 M
Qty:
add to cart
Part #:GPS 6295
Safely and easily deliver power from your portable generator to your home&rsquos electrical panel during a power outage.
$ 660.92
Qty:
add to cart
Part #:MC CABLE63WGREENGRN
6-3C Metal Clad (MC) Cable with Ground, Aluminum Armored, Stranded Copper Conductors Metal Clad Cable may be used for branch, feeder and service for distribution in commercial, industrial, and multi-residential construction. They are suitable for installation in motion picture studios, theaters, and places of assembly (100 people or more) per NEC Articles 230.43, 300.22(C), 330, 396, 518, 520, 530 and 645. These cables may be installed in approved raceways and as open runs of cable on a messenger. They may be installed exposed, concealed or in cable tray and may be run in spaces used for environmental air in accordance with NEC Article 300.22(C) ONLY. - Meets UL 83 Thermoplastic Insulated Wires and Cables- Tested to UL 1479 Fire Tests of Through-Penetration Firestops for one, two or three hour fire rated assemblies (for cables up to #2 AWG)- Meets UL 1569 Metal Clad Cables- Meets UL 1581 Reference Standard for Electrical Wires, Cables, and Flexible Cords- Meets UL 2256 Wire and Cable Test Methods- Designated Type MC per NEC Article 330 Specifications Size6 AWGOutside Diameter0.840 inches Ampere Rating THHN75
$ 5.93 M
Qty:
add to cart
Part #:GPS 6327
GENERAC 6327 Power Cord,10 Ft
$ 116.94
Qty:
add to cart
Part #:GPS 6346
NEMA 3R for outdoor installation Easily mounts on exterior of house or building Heavy duty weather resistant aluminum inlet box
$ 102.96
Qty:
add to cart
Part #:GPS 6347
Use a power inlet box when you need to plug in your generator outdoors Made of NEMA 3R-rated corrosion-resistant aluminum Power cord connects 12500-Watt maximum generator to a NEMA configuration CS6365 inlet box Compatible with generators with 50-Amp outlets including model numbers GP15000E, GP17500E, XG10000E and XP10000E Comes with a 2-year limited warranty
$ 146.16
Qty:
add to cart
Part #:BRADY M21-500-499
B-499 NYLON MATERIAL 16 FT 1/2 INCH WHITE BACKGROUND COLOR BMP[T] 21 LABEL PRINTER PRINTER TYPE BLACK GRAPHIC COLOR BRADY[R] BRAND
$ 48.12 CQ
Qty:
add to cart
Part #:BRADY M21-375-595-WT
B-595 VINYL MATERIAL 21 FT 0.375 INCH WHITE TAPE COLOR BLACK PRINT COLOR BMP 21[R] BRAND APPLICATION SUPER-TOUGH AND PERFECT FOR VOICE, DATA, AUDIO, VIDEO, HVAC CONTROL, BINS, SAFTY AND ELECTRICAL APPLICATIONS
$ 43.34 CQ
Qty:
add to cart
$ 14,787.60
Qty:
add to cart
Part #:GPS 5663
Generac Scheduled service and maintenance kit includes air filter, oil filter, two spark plugs, oil funnel, chamois, reminder sticker and instruction manual. It is perfect for 10 Kilo-Watt 530 CU-CM air cooled engine and all standby generators. Includes air filter, oil filter, two spark plugs, oil funnel, chamois, reminder sticker and instruction manual Suitable for 10 Kilo-Watt, 530 CU-CM air-cooled engine Works well with all standby generators
$ 69.90
Qty:
add to cart
Part #:HOR HE800DIQ712
14 DC Inputs (12/24VDC), 10 Relay Outputs (250vac, 30VDC, 3.0A)
$ 1,618.00
Qty:
add to cart
Part #:CRL 76502.18.06
MTW/TFF/AWM (UL), TEW (CSA) TYPE 2000 FT 2000 LENGTH IN FT 0.11 INCH OUTER DIAMETER ASTM B-8 ANNEALED BARE COPPER CONDUCTOR MATERIAL UL, CSA APPROVAL 600 V VOLTAGE RATING -40 TO 90 DEG C (MTW/TFF), -20 TO 105 DEG C (AWM/TEW) TEMPERATURE RATING 10 LB/MFT WEIGHT PVC INSULATION MATERIAL 18 AWG CONDUCTOR SIZE GREEN COLOR CODE 16/30 STRANDS STRANDING CAROL[R] BRAND LENGTH IN FT - UOM FT
$ 0.13 M
Qty:
add to cart
Part #:CRL 76502.18.07
MTW/TFF/AWM (UL), TEW (CSA) TYPE 2000 FT 2000 LENGTH IN FT 0.11 INCH OUTER DIAMETER ASTM B-8 ANNEALED BARE COPPER CONDUCTOR MATERIAL UL, CSA APPROVAL 600 V VOLTAGE RATING -40 TO 90 DEG C (MTW/TFF), -20 TO 105 DEG C (AWM/TEW) TEMPERATURE RATING 10 LB/MFT WEIGHT PVC INSULATION MATERIAL 18 AWG CONDUCTOR SIZE BLUE COLOR CODE 16/30 STRANDS STRANDING CAROL[R] BRAND LENGTH IN FT - UOM FT
$ 0.16 M
Qty:
add to cart
Part #:MTW 18RD2500
18 AWG MTW/UL1015 Hook-Up Stranded Wire, 600V. 18 AWG UL1015Type conductors are primarily used in control cabinets, in machine tool applications and appliance wiring applications. Applications requiring Type MTW conductor is appropriate for use in dry locations at 90&degC, or not to exceed 60&degC in wet locations or where exposed to oils or coolants. Applications requiring Type AWM conductor is appropriate for use at temperatures to not exceed 105&degC in dry locations.ConductorBare Copper InsulationPolyvinyl Chloride (PVC)StandardsUL recognized AWM Style 1015 per 758. Passes VW-1 vertical flame test. CSA TEW or AWM Specifications Size18 AWGNumber of Strands16Temp105&degCInsulation Thickness0.031 inchesOutside Diameter0.11 inchesWeight0.010 lbs per ftVoltage600V
$ 0.16 M
Qty:
add to cart
Part #:MTW 18BE2500
18 AWG MTW/UL1015 Hook-Up Stranded Wire, 600V. 18 AWG UL1015Type conductors are primarily used in control cabinets, in machine tool applications and appliance wiring applications. Applications requiring Type MTW conductor is appropriate for use in dry locations at 90&degC, or not to exceed 60&degC in wet locations or where exposed to oils or coolants. Applications requiring Type AWM conductor is appropriate for use at temperatures to not exceed 105&degC in dry locations.ConductorBare Copper InsulationPolyvinyl Chloride (PVC)StandardsUL recognized AWM Style 1015 per 758. Passes VW-1 vertical flame test. CSA TEW or AWM Specifications Size18 AWGNumber of Strands16Temp105&degCInsulation Thickness0.031 inchesOutside Diameter0.11 inchesWeight0.010 lbs per ftVoltage600V
$ 0.16 FT
Qty:
add to cart
Part #:CRL 76512.18.02
MTW/TFF/AWM (UL), TEW (CSA) TYPE 2000 FT 2000 LENGTH IN FT 0.123 INCH OUTER DIAMETER ASTM B-8 ANNEALED BARE COPPER CONDUCTOR MATERIAL UL, CSA APPROVAL 600 V VOLTAGE RATING -40 TO 90 DEG C (MTW/TFF), -20 TO 105 DEG C (AWM/TEW) TEMPERATURE RATING 14 LB/MFT WEIGHT PVC INSULATION MATERIAL 16 AWG CONDUCTOR SIZE WHITE COLOR CODE 26/30 STRANDS STRANDING CAROL[R] BRAND LENGTH IN FT - UOM FT
$ 0.22 M
Qty:
add to cart
Part #:CRL 76512.18.03
MTW/TFF/AWM (UL), TEW (CSA) TYPE 2000 FT 2000 LENGTH IN FT 0.123 INCH OUTER DIAMETER ASTM B-8 ANNEALED BARE COPPER CONDUCTOR MATERIAL UL, CSA APPROVAL 600 V VOLTAGE RATING -40 TO 90 DEG C (MTW/TFF), -20 TO 105 DEG C (AWM/TEW) TEMPERATURE RATING 14 LB/MFT WEIGHT PVC INSULATION MATERIAL 16 AWG CONDUCTOR SIZE RED COLOR CODE 26/30 STRANDS STRANDING CAROL[R] BRAND LENGTH IN FT - UOM FT
$ 0.16 M
Qty:
add to cart
 
Displaying: 193 - 216 of 235 Matching Items