Automation Controllers
All in One Controllers
View:
Active Filters :
- Main Category: All in One Controllers Automation Controllers Operator Interfaces Wire
Part #:HOR HE-EXL1E3
- Description
Logic engine features 1MB of application memory with a 0.013mS/K logic scan. Online Programming Mode (making logic changes on the fly without going thru stop mode) is supported. Operator Interface features include
640×480 LCD TFT color graphics display with a high resolution resistive touchscreen
4 function keys and a system key
USB 2.0 On-the-Go port (mini-B 5pin) is available for programming
USB 2.0 Host port (A) is available for exchanging files with USB FLASH drives
Two (2) RS-232 and one (1) RS-485 port support RTU/Modbus Master/Slave, ASCII In/Out, and PLC/Drive downloadable protocols
Networking features include
Built-in 10/100 Ethernet port
Integrated CsCAN port
All units feature a microSD slot, supporting at least 32GB. COM option expansion modules are supported, including Profibus DP, 2ch/4ch Analog Output, Radio Modem, Telephone Modem, and GPRS Cellular Modem. The COM options are independent of the serial ports.
$
2,190.00
Qty:
Part #:HOR HE-XC1E5-110
- Description
Logic engine features 1MB of application memory with a 0.013mS/K logic scan.
Online Programming Mode (making logic changes on the fly without going thru stop mode) is supported.
Operator Interface features include a 320×240 LCD TFT color graphics display with a high resolution resistive touchscreen, 4 function keys and a system key
A USB 2.0 On-the-Go port (mini-B 5pin) is available for programming.
A USB 2.0 Host port (A) is available for exchanging files with USB FLASH drives.
One (1) RS-232 and one (1) 485 port support RTU/Modbus Master/Slave, ASCII In/Out, and PLC/Drive downloadable protocols.
Networking features include a built-in 10/100 Ethernet port, and an integrated CsCAN port.
All units feature a microSD slot, supporting at least 32GB.
COM option expansion modules are supported, including Profibus DP, 2ch/4ch Analog Output, Radio Modem, Telephone Modem, and GPRS Cellular Modem. The COM options are independent of the serial ports.
$
853.00
Qty:
Part #:MC 123WG1KR
- Metal Clad Cable may be used for branch, feeder and service for distribution in commercial, industrial, and multi-residential construction. They are suitable for installation in motion picture studios, theaters, and places of assembly (100 people or more) per NEC Articles 230.43, 300.22(C), 330, 396, 518, 520, 530 and 645. These cables may be installed in approved raceways and as open runs of cable on a messenger. They may be installed exposed, concealed or in cable tray and may be run in spaces used for environmental air in accordance with NEC Article 300.22(C) ONLY.
Meets UL 83 Thermoplastic Insulated Wires and Cables- Tested to UL 1479 Fire Tests of Through-Penetration Firestops for one, two or three hour fire rated assemblies (for cables up to #2 AWG)- Meets UL 1569 Metal Clad Cables- Meets UL 1581 Reference Standard for Electrical Wires, Cables, and Flexible Cords- Meets UL 2256 Wire and Cable Test Methods- Designated Type MC per NEC Article 330
Size12 AWGOutside Diameter0.509 inches
$
2.08
M
Qty:
Part #:MC 142WG1KR
- Metal Clad Cable may be used for branch, feeder and service for distribution in commercial, industrial, and multi-residential construction. They are suitable for installation in motion picture studios, theaters, and places of assembly (100 people or more) per NEC Articles 230.43, 300.22(C), 330, 396, 518, 520, 530 and 645. These cables may be installed in approved raceways and as open runs of cable on a messenger. They may be installed exposed, concealed or in cable tray and may be run in spaces used for environmental air in accordance with NEC Article 300.22(C) ONLY.
- Meets UL 83 Thermoplastic Insulated Wires and Cables- Tested to UL 1479 Fire Tests of Through-Penetration Firestops for one, two or three hour fire rated assemblies (for cables up to #2 AWG)- Meets UL 1569 Metal Clad Cables- Meets UL 1581 Reference Standard for Electrical Wires, Cables, and Flexible Cords- Meets UL 2256 Wire and Cable Test Methods- Designated Type MC per NEC Article 330
Specifications
Size14 AWGOutside Diameter0.441 inches
Ampere Rating THHN15
$
0.41
M
Qty:
Part #:NMB 82WG1KR
- 8-2 W/G NM-B Wire Black
Non-metallic sheathed NM-B cable is used in normally dry installations in residential wiring, as branch circuits for outlets, lighting and other residential loads. Its applications are outlined in NEC 2008 and NEC 2011 Article 334. NM-B is rated at 600 volts and although it is rated at a conductor temperature of 90°C dry , its ampacity is limited to 60°C according to the NEC 2008 and NEC 2011. It may be fished through masonry or tile walls, where not exposed or subject to excessive moisture or dampness. NM-B cables are LEAD FREE and RoHS compliant. Equivalent to Romex NM-B.
StandardsMeets or exceeds all applicable ASTM specificationsUL 83 Thermoplastic Insulated Wires and CablesUL 719 Non-Metallic CablesFederal Specification A-A-59544 and requirements of the NEC.Voltage rating - 600 volts.
ConstructionConductorsSolid 14 to 10 AWG annealed soft bare copper per ASTM B3.Stranded 8 AWG and larger annealed soft bare copper per ASTM B3 and B8.InsulationColor coded polyvinyl chloride (PVC) compound with a nylon covering meeting the required thickness of Type THHN. Conductor insulation is rated 90°C.GroundSoft, bare copper solid per ASTM B3 and stranded per ASTM B3 and B8Sheath30 mil color coded PVC sheath rated 90C is applied over the completed assembly
Specifications
Size8 AWGNumber of Conductors2PVC Insulation Thickness0.76 mm / 0.029 inchesGround Wire Size10 AWGNylon Thickness0.13 mm / 0.005 inchesNominal Cable Dimensions6.9 x 15.0 mm / 0.27 x 0.59 inchesWeight per foot0.186 lbsAllowable Ampacity40 Amps
$
1.40
M
Qty:
Part #:NMB 83WG1KR
- 8-3 W/G NM-B Wire Black
Non-metallic sheathed NM-B cable is used in normally dry installations in residential wiring, as branch circuits for outlets, lighting and other residential loads. Its applications are outlined in NEC 2008 and NEC 2011 Article 334. NM-B is rated at 600 volts and although it is rated at a conductor temperature of 90°C dry , its ampacity is limited to 60°C according to the NEC 2008 and NEC 2011. It may be fished through masonry or tile walls, where not exposed or subject to excessive moisture or dampness. NM-B cables are LEAD FREE and RoHS compliant. Equivalent to Romex NM-B.
StandardsMeets or exceeds all applicable ASTM specificationsUL 83 Thermoplastic Insulated Wires and CablesUL 719 Non-Metallic CablesFederal Specification A-A-59544 and requirements of the NEC.Voltage rating - 600 volts.
ConstructionConductorsSolid 14 to 10 AWG annealed soft bare copper per ASTM B3.Stranded 8 AWG and larger annealed soft bare copper per ASTM B3 and B8.InsulationColor coded polyvinyl chloride (PVC) compound with a nylon covering meeting the required thickness of Type THHN. Conductor insulation is rated 90°C.GroundSoft, bare copper solid per ASTM B3 and stranded per ASTM B3 and B8Sheath30 mil color coded PVC sheath rated 90C is applied over the completed assembly
Specifications
Size8 AWGNumber of Conductors3PVC Insulation Thickness0.76 mm / 0.029 inchesGround Wire Size10 AWGNylon Thickness0.13 mm / 0.005 inchesNominal Cable Dimensions14.2mm / 0.55 inchesWeight per foot0.254 lbsAllowable Ampacity40 Amps
$
3.38
M
Qty:
$
3.30
FT
Qty:
closeout
Part #:THHN 1OBK1000
- CLOSEOUTS Only 153 Left!
- APPLICATIONS
Southwire Type THHN or THWN-2 conductors are primarily used in conduit and cable trays for services, feeders, and branch circuits in commercial or industrial applications as specified in the 2008 National Electrical Code. When used as Type THHN, or T90 Nylon conductor is suitable for use in dry locations at temperatures not to exceed 90 °C. When used as Type THWN-2 or TWN75, conductor is suitable for use in wet or dry locations at temperatures not to exceed 90 °C or not to exceed 75 °C when exposed to oil or coolant. When used as Type MTW, conductor is suitable for use in wet locations or when exposed to oil or coolant at temperatures not to exceed 60 °C or dry locations at temperatures not to exceed 90 °C (with ampacity limited to that for 75 °C conductor temperature per NFPA 79). Conductor temperatures not to exceed 105 °C in dry locations when rated AWM and used as appliance wiring material or when used asT90 Nylon. Voltage for all applications is 600 volts.
$
2.24
M
Qty:
Part #:THHN 1OBK500
- APPLICATIONS
Southwire Type THHN or THWN-2 conductors are primarily used in conduit and cable trays for services, feeders, and branch circuits in commercial or industrial applications as specified in the 2008 National Electrical Code. When used as Type THHN, or T90 Nylon conductor is suitable for use in dry locations at temperatures not to exceed 90 °C. When used as Type THWN-2 or TWN75, conductor is suitable for use in wet or dry locations at temperatures not to exceed 90 °C or not to exceed 75 °C when exposed to oil or coolant. When used as Type MTW, conductor is suitable for use in wet locations or when exposed to oil or coolant at temperatures not to exceed 60 °C or dry locations at temperatures not to exceed 90 °C (with ampacity limited to that for 75 °C conductor temperature per NFPA 79). Conductor temperatures not to exceed 105 °C in dry locations when rated AWM and used as appliance wiring material or when used asT90 Nylon. Voltage for all applications is 600 volts.
$
4.01
M
Qty:
Part #:UF 142WG1KR
-
Underground Feeder and Branch Circuit Cable
600 Volt
Copper Conductors
Sunlight, Moisture, and Fungus Resistant Overall PVC Jacket
Applications
Southwire Type UF-B cable is generally used as feeder to outside post lamps, pumps, and other loads or apparatus fed from a distribution point in an existing building as specified in the National Electrical Code.1 UF-B cable may be used underground, including direct burial. Multiple conductor UF-B cable may be used for interior branch circuit wiring in residential or agricultural buildings at conductor temperatures not to exceed 90°C (with ampacity limited to that for 60°C conductors) as specified by the National Electrical Code. UF-B can be used in applications permitted for NMC in Section 334.10(B) of the National Electrical Code. Voltage rating for UF-B cable is 600 volts.
$
0.43
M
Qty:
Part #:MTW 10WE500
- 10 AWG MTW Stranded Wire, 600V.
Type conductors are primarily used in control cabinets, in machine tool applications and appliance wiring applications. Applications requiring Type MTW conductor is appropriate for use in dry locations at 90°C, or not to exceed 60°C in wet locations or where exposed to oils or coolants. Applications requiring Type AWM conductor is appropriate for use at temperatures to not exceed 105°C in dry locations.
E315270 12 AWG (UL) MTW OR THHW OR BC-5W2 OR AWM 1011/1015/1230/1335 600V OR 1032/10269 1000V, VW-1---240954 CSA TEW 600V OR AWM 1 A/B 105C 1000V FT-1---SAE J1128 TYPE GPT
Specifications
Size10 AWGNumber of Strands19 or 105Temp105°CInsulation Thickness0.030 inchesOutside Diameter0.205 inchesVoltage600V
$
0.99
M
Qty:
Part #:MTW 14BKS5KDRUM10
- 14 AWG MTW Stranded Wire, 600V.
Type conductors are primarily used in control cabinets, in machine tool applications and appliance wiring applications. Applications requiring Type MTW conductor is appropriate for use in dry locations at 90°C, or not to exceed 60°C in wet locations or where exposed to oils or coolants. Applications requiring Type AWM conductor is appropriate for use at temperatures to not exceed 105°C in dry locations.
Bare Copper StrandingE315270 14 AWG (UL) MTW OR THHW OR BC-5W2 OR AWM 1011/1015/1230/1335 600V OR 1032/10269 1000V, VW-1---240954 CSA TEW 600V OR AWM 1 A/B 105C 1000V FT-1---SAE J1128 TYPE GPT
Specifications
Size14 AWGNumber of Strands19 or 41Temp105°CInsulation Thickness0.030 inchesOutside Diameter0.132 inchesVoltage600V
$
0.33
M
Qty:
Part #:MTW 14GRWY5KDRUM10
- 14 AWG MTW Stranded Wire, 600V.
Type conductors are primarily used in control cabinets, in machine tool applications and appliance wiring applications. Applications requiring Type MTW conductor is appropriate for use in dry locations at 90°C, or not to exceed 60°C in wet locations or where exposed to oils or coolants. Applications requiring Type AWM conductor is appropriate for use at temperatures to not exceed 105°C in dry locations.
Bare Copper StrandingE315270 14 AWG (UL) MTW OR THHW OR BC-5W2 OR AWM 1011/1015/1230/1335 600V OR 1032/10269 1000V, VW-1---240954 CSA TEW 600V OR AWM 1 A/B 105C 1000V FT-1---SAE J1128 TYPE GPT
Specifications
Size14 AWGNumber of Strands19 or 41Temp105°CInsulation Thickness0.030 inchesOutside Diameter0.132 inchesVoltage600V
$
0.34
M
Qty:
Part #:MTW 14WHT5KDRUM10
- 14 AWG MTW Stranded Wire, 600V.
Type conductors are primarily used in control cabinets, in machine tool applications and appliance wiring applications. Applications requiring Type MTW conductor is appropriate for use in dry locations at 90°C, or not to exceed 60°C in wet locations or where exposed to oils or coolants. Applications requiring Type AWM conductor is appropriate for use at temperatures to not exceed 105°C in dry locations.
Bare Copper StrandingE315270 14 AWG (UL) MTW OR THHW OR BC-5W2 OR AWM 1011/1015/1230/1335 600V OR 1032/10269 1000V, VW-1---240954 CSA TEW 600V OR AWM 1 A/B 105C 1000V FT-1---SAE J1128 TYPE GPT
Specifications
Size14 AWGNumber of Strands19 or 41Temp105°CInsulation Thickness0.030 inchesOutside Diameter0.132 inchesVoltage600V
$
0.33
M
Qty:
Part #:MTW 16BLU5KDRUM10
- 16 AWG MTW/UL1015 Hook-Up Stranded Wire, 600V.
16 AWG UL1015 Type conductors are primarily used in control cabinets, in machine tool applications and appliance wiring applications. Applications requiring Type MTW conductor is appropriate for use in dry locations at 90°C, or not to exceed 60°C in wet locations or where exposed to oils or coolants. Applications requiring Type AWM conductor is appropriate for use at temperatures to not exceed 105°C in dry locations.ConductorBare Copper
InsulationPolyvinyl Chloride (PVC)StandardsUL recognized AWM Style 1015 per 758. Passes VW-1 vertical flame test. CSA TEW or AWM
Specifications
Size16 AWGNumber of Strands26Temp105°CInsulation Thickness0.031 inchesOutside Diameter0.124 inchesWeight0.014 lbs per ftVoltage600V
$
0.24
M
Qty:
Part #:MTW 16BRN5KDRUM10
- 16 AWG MTW/UL1015 Hook-Up Stranded Wire, 600V.
16 AWG UL1015 Type conductors are primarily used in control cabinets, in machine tool applications and appliance wiring applications. Applications requiring Type MTW conductor is appropriate for use in dry locations at 90°C, or not to exceed 60°C in wet locations or where exposed to oils or coolants. Applications requiring Type AWM conductor is appropriate for use at temperatures to not exceed 105°C in dry locations.ConductorBare Copper
InsulationPolyvinyl Chloride (PVC)StandardsUL recognized AWM Style 1015 per 758. Passes VW-1 vertical flame test. CSA TEW or AWM
Specifications
Size16 AWGNumber of Strands26Temp105°CInsulation Thickness0.031 inchesOutside Diameter0.124 inchesWeight0.014 lbs per ftVoltage600V
$
0.24
M
Qty:
Part #:MTW 16ORG5KDRUM10
- 16 AWG MTW/UL1015 Hook-Up Stranded Wire, 600V.
16 AWG UL1015 Type conductors are primarily used in control cabinets, in machine tool applications and appliance wiring applications. Applications requiring Type MTW conductor is appropriate for use in dry locations at 90°C, or not to exceed 60°C in wet locations or where exposed to oils or coolants. Applications requiring Type AWM conductor is appropriate for use at temperatures to not exceed 105°C in dry locations.ConductorBare Copper
InsulationPolyvinyl Chloride (PVC)StandardsUL recognized AWM Style 1015 per 758. Passes VW-1 vertical flame test. CSA TEW or AWM
Specifications
Size16 AWGNumber of Strands26Temp105°CInsulation Thickness0.031 inchesOutside Diameter0.124 inchesWeight0.014 lbs per ftVoltage600V
$
0.24
M
Qty:
closeout
Part #:THHN 10BK2500
- CLOSEOUTS Only 2500 Left!
- APPLICATIONS
Southwire Type THHN or THWN-2 conductors are primarily used in conduit and cable trays for services, feeders, and branch circuits in commercial or industrial applications as specified in the 2008 National Electrical Code. When used as Type THHN, or T90 Nylon conductor is suitable for use in dry locations at temperatures not to exceed 90 °C. When used as Type THWN-2 or TWN75, conductor is suitable for use in wet or dry locations at temperatures not to exceed 90 °C or not to exceed 75 °C when exposed to oil or coolant. When used as Type MTW, conductor is suitable for use in wet locations or when exposed to oil or coolant at temperatures not to exceed 60 °C or dry locations at temperatures not to exceed 90 °C (with ampacity limited to that for 75 °C conductor temperature per NFPA 79). Conductor temperatures not to exceed 105 °C in dry locations when rated AWM and used as appliance wiring material or when used asT90 Nylon. Voltage for all applications is 600 volts.
$
0.34
M
Qty:
Part #:HOU 1202LVL1000
- Underground Low-Voltage Landscape Lighting Cable. 30V Flat Parallel, PVC Insulated
ColorBlack
ApplicationsLow-voltage outdoor landscape lighting and security lighting circuits where cable must be suitable for direct burial.
Compliances- RoHS Compliant Directive 2002/95/EC- UL Listed Type CL2
ConductorAnnealed stranded bare copper per ASTM B-3
InsulationPremium-grade, color-coded PVC
JacketPolyvinylchloride (PVC)-20°C to +105°C
Specifications
Size12 AWGNumber of Conductors2Stranding65/30Insulation Thickness.041 inchesOutside Diameter0.390 X 0.195 inches
$
0.67
M
Qty:
Part #:SER 6666AL1000R
- SER is type SE, Style R cable, used as an above ground service entrance cable, a panel feeder and in branch circuits. The cable is rated at 600 volts and 90_C for use in wet and dry locations. SER cables are LEAD FREE and RoHS compliant.
ConstructionConductor - Compact stranded AA-8000 series aluminum alloy (ACM) per ASTM B801 or B836. #8 AWG is solid AA-8000 series aluminum alloy (ACM) per ASTM B800.Insulation - Color coded cross-linked polyethylene (XLPE).Assembly - Insulated conductors are cabled with the bare ground wire. A flame retardant fiberglass reinforced binder tape assembles the core in a circular configuration.Jacket - Sunlight resistant, LEAD FREE, flame retardant, gray polyvinyl chloride (PVC) material.
StandardsMeets UL 854 Service Entrance Cable
Specifications
Insulated Conductor Size6 AWGBare Neutral Size6 AWG (7)Outside Diameter0.717 inchesAmpacity amps60Net Weight.196 lbs/ft
$
5.21
M
Qty:
$
4.84
M
Qty:
Part #:WIRE NM-B-12/2-CU-WG-1000S/R
- NM-B TYPE 1000 FT 0.16 INCH X 0.45 INCH OUTER DIAMETER ANNEALED SOFT COPPER CONDUCTOR MATERIAL UL 83/719 APPROVAL 600 V VOLTAGE RATING 20 AMPERE CURRENT RATING 90 DEG C TEMPERATURE RATING 82 LB/MFT WEIGHT 2 CONDUCTOR(S) PVC INSULATION MATERIAL WITH GROUND WIRE 12 AWG CONDUCTOR SIZE BLACK, WHITE COLOR CODE YELLOW PVC JACKET MATERIAL SPOOL/REEL PACKAGE TYPE SOLID STRANDING 12 AWG GROUND CONDUCTOR SIZE
$
8.53
FT
Qty:
Part #:HOR HE-XE102
- Features of the XLE Operator Interface include
128×64 graphical display
20-key keypad with function key and numeric entry capability
Logic engine features 256KB of application memory with a 0.7mS/K logic scan.
(2) RS-232/485 ports support RTU/Modbus Master/Slave, ASCII In/Out, and PLC/Drive downloadable protocols
integrated CsCAN port
Removable Mass Storage device
CANopen Master/Slave Support
$
751.00
Qty:
Part #:WIRE MC-STL-10/2-SOL-W/GRN-GRD
- MC TYPE 0.502 INCH OUTER DIAMETER SOFT DRAWN COPPER CONDUCTOR MATERIAL UL 83, UL 1569 APPROVAL 600 V VOLTAGE RATING 30 AMPERE CURRENT RATING 90 DEG C TEMPERATURE RATING 210 LB/MFT WEIGHT 2 CONDUCTOR(S) THHN/THWN INSULATION MATERIAL 10 AWG CONDUCTOR SIZE PVC JACKET MATERIAL SOLID STRANDING STEEL ARMOR MATERIAL 10 AWG GREEN INSULATED GROUND CONDUCTOR TYPE
$
2.97
M
Qty:
Displaying: 73 - 96 of 249 Matching Items