Automation Controllers
All in One Controllers
View:
Active Filters :
- Main Category: All in One Controllers Automation Controllers Operator Interfaces Wire
Part #:WIRE NM-B-12/3-CU-WG-1000S/R
- NM-B TYPE 1000 FT 347 MIL OUTER DIAMETER SOFT ANNEALED COPPER CONDUCTOR MATERIAL UL 83/719 APPROVAL 600 V VOLTAGE RATING 20 AMPERE CURRENT RATING 90 DEG C (DRY) TEMPERATURE RATING 107 LB/MFT WEIGHT 3 CONDUCTOR(S) PVC INSULATION MATERIAL WITH GROUND WIRE 12 AWG CONDUCTOR SIZE PVC JACKET MATERIAL SPOOL/REEL PACKAGE TYPE SOLID STRANDING 12 AWG GROUND CONDUCTOR SIZE ROHS COMPLIANT INSULATION THICKNESS 0.015 INCH JACKET COLOR YELLOW APPLICABLE STANDARD FEDERAL SPECIFICATION A-A-59544, ARRA, NEC
$
11.65
FT
Qty:
Part #:WIRE NM-B-10/3-CU-WG-1000S/R
- NM-B TYPE 1000 FT 422 MIL OUTER DIAMETER SOFT ANNEALED COPPER CONDUCTOR MATERIAL UL 83/719 APPROVAL 600 V VOLTAGE RATING 30 AMPERE CURRENT RATING 90 DEG C (DRY) TEMPERATURE RATING 164 LB/MFT WEIGHT 3 CONDUCTOR(S) PVC INSULATION MATERIAL WITH GROUND WIRE 10 AWG CONDUCTOR SIZE PVC JACKET MATERIAL SPOOL/REEL PACKAGE TYPE SOLID STRANDING 10 AWG GROUND CONDUCTOR SIZE ROHS COMPLIANT INSULATION THICKNESS 0.02 INCH JACKET COLOR ORANGE APPLICABLE STANDARD FEDERAL SPECIFICATION A-A-59544, ARRA, NEC
$
18.35
FT
Qty:
$
3.53
M
Qty:
$
4.94
M
Qty:
Part #:WIRE UF-B-6/2-CU-WG-125CL
- UF-B TYPE 125 FT 770 MIL X 338 MIL OUTER DIAMETER ANNEALED SOFT COPPER CONDUCTOR MATERIAL UL 83/493 APPROVAL 600 V VOLTAGE RATING 55 AMPERE CURRENT RATING 90 DEG C TEMPERATURE RATING 303 LB/MFT WEIGHT 2 CONDUCTOR(S) PVC INSULATION MATERIAL WITH GROUND WIRE 6 AWG CONDUCTOR SIZE NYLON JACKET MATERIAL COIL PACKAGE TYPE 7 STRANDS STRANDING 10 AWG GROUND CONDUCTOR SIZE
$
38.62
FT
Qty:
Part #:MC CABLE62WGREENGRN
- Metal Clad Cable may be used for branch, feeder and service for distribution in commercial, industrial, and multi-residential construction. They are suitable for installation in motion picture studios, theaters, and places of assembly (100 people or more) per NEC Articles 230.43, 300.22(C), 330, 396, 518, 520, 530 and 645. These cables may be installed in approved raceways and as open runs of cable on a messenger. They may be installed exposed, concealed or in cable tray and may be run in spaces used for environmental air in accordance with NEC Article 300.22(C) ONLY.
- Meets UL 83 Thermoplastic Insulated Wires and Cables- Tested to UL 1479 Fire Tests of Through-Penetration Firestops for one, two or three hour fire rated assemblies (for cables up to #2 AWG)- Meets UL 1569 Metal Clad Cables- Meets UL 1581 Reference Standard for Electrical Wires, Cables, and Flexible Cords- Meets UL 2256 Wire and Cable Test Methods- Designated Type MC per NEC Article 330
Size6 AWGOutside Diameter0.755 inches
Ampere Rating THHN75 @ 90°C
$
3.96
M
Qty:
$
1.12
M
Qty:
$
1.23
FT
Qty:
$
1.19
M
Qty:
Part #:USE 02BKSTAL1R
-
Cable Type Direct Burial Wire, USE-RHH-RHW
Conductor Material Aluminum
Insulation XLPE
Voltage 600V
Conductor Size 2 AWG
Conductor Strands 7-Str
Color Black
Temperature Rating 90°C
Package Type Reel
$
0.92
M
Qty:
Part #:USE 20BKSTAL5000R
- USE/RHH/RHW Underground service entrance cable in black color, has 18-Strand aluminum conductor of size 2/0 AWG. It features 80-mil cross-linked polyethylene insulation that offers resistance against moisture, heat and sunlight. Cable has voltage rating of 600 Volts and current rating of 150 Amps. It has outer diameter of 536 mil. Cable withstands temperature rating of 90 deg C in dry conditions. Cable is UL listed, RoHS/REACH compliant, NEMA rated and meets ASTM standards.
$
1.16
M
Qty:
Part #:USE 4OBKSTRAL500R
-
Cable Type Direct Burial Wire, USE-RHH-RHW
Conductor Material Copper
Insulation XLPE
Voltage 600V
Conductor Size 4 AWG
Conductor Strands 7-Str
Color Black
Temperature Rating 90°C
Package Length 500-ft
Package Type Reel
$
1.65
M
Qty:
Part #:SER 2224AL1000R
- Type SE, Style SER Service Entrance may be used as service-entrance conductors and in other applications where SE cables are permitted when installed as specified by NEC® dry locations at temperatures up to 90°C.
ConductorStranded conductors Uncoated copper per ASTM-B3, ASTM-B8, and ASTM-B787
Phase ConductorType THHN conductors Black PVC (polyvinyl chloride), rated to 90°C in wet or dry locations Jacketed with black nylon (polyamide) One phase conductor has a red stripe on its insulation surface for easy polarity identification.
Neutral ConductorWhite PVC (polyvinyl chloride), rated 90°C Jacketed with white nylon (polyamide)
Equipment Ground ConductorBare stranded copper conductor
JacketGray, sunlight-resistant PVC (polyvinyl chloride) jacket over the complete assembly
StandardsUL 83 (insulated conductors)UL 854 Service Entrance Cables, File No. 11098ASTM-B3ASTM-B8ASTM-B787Federal Specification A-A-59544NFPA70 National Electrical Code
Specifications
Insulated Conductor Size2 AWGBare Ground Size4 AWG (7)Outside Diameter0.970 inchesAmpacity amps125 @90°CNet Weight.899 lbs/ft
$
1.95
M
Qty:
Part #:SER 1113AL500R
- SER is type SE, Style R cable, used as an above ground service entrance cable, a panel feeder and in branch circuits. The cable is rated at 600 volts and 90_C for use in wet and dry locations. SER cables are LEAD FREE and RoHS compliant.
ConstructionConductor - Compact stranded AA-8000 series aluminum alloy (ACM) per ASTM B801 or B836. #8 AWG is solid AA-8000 series aluminum alloy (ACM) per ASTM B800.Insulation - Color coded cross-linked polyethylene (XLPE).Assembly - Insulated conductors are cabled with the bare ground wire. A flame retardant fiberglass reinforced binder tape assembles the core in a circular configuration.Jacket - Sunlight resistant, LEAD FREE, flame retardant, gray polyvinyl chloride (PVC) material.
Specifications
Insulated Conductor Size1 AWGInsulation Thickness0.055 inchesBare Neutral Size3 AWG (7)Jacket Thickness0.030 inchesOutside Diameter0.97 inchesAmpacity amps110Net Weight0.45 lbs per ft
$
3.06
M
Qty:
Part #:UF 123WG
-
Underground Feeder and Branch Circuit Cable
600 Volt
Copper Conductors
Sunlight, Moisture, and Fungus Resistant Overall PVC Jacket
Applications
Southwire Type UF-B cable is generally used as feeder to outside post lamps, pumps, and other loads or apparatus fed from a distribution point in an existing building as specified in the National Electrical Code.1 UF-B cable may be used underground, including direct burial. Multiple conductor UF-B cable may be used for interior branch circuit wiring in residential or agricultural buildings at conductor temperatures not to exceed 90°C (with ampacity limited to that for 60°C conductors) as specified by the National Electrical Code. UF-B can be used in applications permitted for NMC in Section 334.10(B) of the National Electrical Code. Voltage rating for UF-B cable is 600 volts.
$
0.71
M
Qty:
Part #:CRL 03662.63.07
- BLUE COLOR 100 FT 100 LENGTH IN FT 5-15P, 5-15R CONFIGURATION UL APPROVAL SNOW BLOWER, ENGINE HEATER, BATTERY CHARGER, OUTDOOR EQUIPMENT APPLICATION 125 V VOLTAGE RATING 13 AMPERE CURRENT RATING 3 CONDUCTOR(S) 14 AWG CONDUCTOR SIZE SJEOOW CORD TYPE CAROL[R] BRAND WATTAGE 1625 W TEMPERATURE RANGE -50 TO 105 DEG C CONDUCTOR MATERIAL STRANDED BARE COPPER PACKAGE QUANTITY 2 PER CARTON LENGTH IN FT - UOM FT
$
109.06
Qty:
Part #:CRL 76832.18.01
- MTW/TFF/AWM (UL), TEW (CSA) TYPE 500 FT 500 LENGTH IN FT 0.179 INCH OUTER DIAMETER ASTM B-8 ANNEALED BARE COPPER CONDUCTOR MATERIAL UL, CSA APPROVAL 600 V VOLTAGE RATING -40 TO 90 DEG C (MTW/TFF), -20 TO 105 DEG C (AWM/TEW) TEMPERATURE RATING 42 LB/MFT WEIGHT PVC INSULATION MATERIAL 10 AWG CONDUCTOR SIZE BLACK COLOR CODE SPOOL PACKAGE TYPE 19/0.0234 STRANDS STRANDING CAROL[R] BRAND LENGTH IN FT - UOM FT
$
0.65
M
Qty:
Part #:CRL 76512.18.10
- MTW/TFF/AWM (UL), TEW (CSA) TYPE 2000 FT 2000 LENGTH IN FT 0.123 INCH OUTER DIAMETER ASTM B-8 ANNEALED BARE COPPER CONDUCTOR MATERIAL UL, CSA APPROVAL 600 V VOLTAGE RATING -40 TO 90 DEG C (MTW/TFF), -20 TO 105 DEG C (AWM/TEW) TEMPERATURE RATING 14 LB/MFT WEIGHT PVC INSULATION MATERIAL 16 AWG CONDUCTOR SIZE GRAY COLOR CODE 26/30 STRANDS STRANDING CAROL[R] BRAND LENGTH IN FT - UOM FT
$
0.16
M
Qty:
Part #:CRL 76512.18.04
- MTW/TFF/AWM (UL), TEW (CSA) TYPE 2000 FT 2000 LENGTH IN FT 0.123 INCH OUTER DIAMETER ASTM B-8 ANNEALED BARE COPPER CONDUCTOR MATERIAL UL, CSA APPROVAL 600 V VOLTAGE RATING -40 TO 90 DEG C (MTW/TFF), -20 TO 105 DEG C (AWM/TEW) TEMPERATURE RATING 14 LB/MFT WEIGHT PVC INSULATION MATERIAL 16 AWG CONDUCTOR SIZE ORANGE COLOR CODE 26/30 STRANDS STRANDING CAROL[R] BRAND LENGTH IN FT - UOM FT
$
0.30
M
Qty:
Part #:CRL E1022S.30.10
- CMR, CL3R TYPE 1000 FT 0.134 INCH OUTER DIAMETER STRANDED BARE COPPER CONDUCTOR MATERIAL UL APPROVAL POWER-LIMITED CONTROL CIRCUIT, INTERCOM, AUDIO, BACKGROUND MUSIC APPLICATION 300 V VOLTAGE RATING -20 TO 75 DEG C TEMPERATURE RATING 2 CONDUCTOR(S) PVC INSULATION MATERIAL 20 AWG CONDUCTOR SIZE BLACK, RED COLOR CODE PVC JACKET MATERIAL GRAY JACKET COLOR CAROL[R] BRAND
$
0.14
Qty:
Part #:MC G08155003
- Miniature rocker switches feature plastic snap-in bezels for easy installation. Illuminated, smooth,two-surface or Stylette&trade solid rockers are available to fit your specifications
Specifications Panel Opening&bull UL recognized, CSA certified&mdash 12A, 125VAC&mdash 5A, 277VAC&mdash 1/2 HP, 125-250VAC&bull 125VAC Neon Lamp Standard lamp voltage willdetermine the switch voltage rating.
$
3.52
Qty:
closeout
Part #:EMERSON IC693ACC307
- Availability: Out of stock
-
IC693ACC307
I/O BUS TERMINATOR PLUG
25PIN
FOR 90-30 SERIES
$
147.00
Qty:
Part #:HOR HE-EXL1E2
- EXL6 Series OCS with DC/Relay I/O. Twelve (12) Digital Inputs compatible with 12V/24VDC &ndash four (4) inputs can be used for two 500kHz High Speed Counters. Six (6) Relay Outputs &ndash up to 5A continuous current. Four (4) 12-bit Analog Inputs selectable between 0-10V and 4-20mA.
$
2,116.00
Qty:
Displaying: 49 - 72 of 249 Matching Items