Automation Controllers
All in One Controllers


Displaying: 97 - 120 of 258 Matching Items
258 Items
View:
Part #:HOR HE-XE102
Features of the XLE Operator Interface include 128&times64 graphical display 20-key keypad with function key and numeric entry capability Logic engine features 256KB of application memory with a 0.7mS/K logic scan. (2) RS-232/485 ports support RTU/Modbus Master/Slave, ASCII In/Out, and PLC/Drive downloadable protocols integrated CsCAN port Removable Mass Storage device CANopen Master/Slave Support
$ 751.00
Qty:
add to cart
Part #:WIRE MC-STL-10/2-SOL-W/GRN-GRD
MC TYPE 0.502 INCH OUTER DIAMETER SOFT DRAWN COPPER CONDUCTOR MATERIAL UL 83, UL 1569 APPROVAL 600 V VOLTAGE RATING 30 AMPERE CURRENT RATING 90 DEG C TEMPERATURE RATING 210 LB/MFT WEIGHT 2 CONDUCTOR(S) THHN/THWN INSULATION MATERIAL 10 AWG CONDUCTOR SIZE PVC JACKET MATERIAL SOLID STRANDING STEEL ARMOR MATERIAL 10 AWG GREEN INSULATED GROUND CONDUCTOR TYPE
$ 2.97 M
Qty:
add to cart
$ 12.00 M
Qty:
add to cart
$ 3.82 M
Qty:
add to cart
Part #:SJOW ASJO103BLK250C
$ 4.15 M
Qty:
add to cart
Part #:SOOW 104BLK250REEL
$ 5.10 M
Qty:
add to cart
Part #:SOOW ASOW104BLK250C
10/4 SOOW Flexible Cord applications include portable tools and equipment, portable appliances, small motors and associated machinery Also Known As10-4 SO Cord, Generator Cord, Rubber Cord, 10 Gauge 4 Wire Cord. FeaturesExcellent resistance to oil and moisture. Good tensile strength, elongation and aging characteristics. High flexibility. Excellent abrasion resistance. Sunlight-resistant. UL Listed and CSA Certified for indoor and outdoor use. Temperature range -40&ordmC to +90&ordmC StandardsUL Flexible Cord - UL Subject 62CSA Flexible Cord - C22.2-49MSHA ApprovedRoHS Compliant ConstructionConductors18 through 2 AWG fully annealed stranded bare copper per ASTM B-174InsulationPremium-grade, color-coded 90&ordmC EPDM. Color Code4 Conductors &ndash Black, White, Red, Green
$ 3.95 M
Qty:
add to cart
Part #:HOR HEXT105110
Description Features of the XLT Operator Interface include 160&times128 sunlight readable graphics display high resolution resistive touchscreen 4 function keys and a system key (2) RS-232/485 ports support RTU/Modbus Master/Slave, ASCII In/Out, and PLC/Drive downloadable protocols integrated CsCAN port Removable Mass Storage device CANopen Master/Slave Support (available as a field installable firmware update, this removes CsCAN support)
$ 926.00
Qty:
add to cart
Part #:MTW 12GN500
$ 0.32 M
Qty:
add to cart
Part #:TGGT 12WH500R
600V, 250C Stranded nickle-plated copper PTFE Tape with glass serve Impregnated glass braid jacket UL/CSA, RoHS Internal wiring of cooking appliances Applications where heat and moisture resistance and flexibility is required
$ 2.05 M
Qty:
add to cart
Part #:THHN 12BKS500
APPLICATIONS Southwire Type THHN or THWN-2 conductors are primarily used in conduit and cable trays for services, feeders, and branch circuits in commercial or industrial applications as specified in the 2008 National Electrical Code. When used as Type THHN, or T90 Nylon conductor is suitable for use in dry locations at temperatures not to exceed 90 &degC. When used as Type THWN-2 or TWN75, conductor is suitable for use in wet or dry locations at temperatures not to exceed 90 &degC or not to exceed 75 &degC when exposed to oil or coolant. When used as Type MTW, conductor is suitable for use in wet locations or when exposed to oil or coolant at temperatures not to exceed 60 &degC or dry locations at temperatures not to exceed 90 &degC (with ampacity limited to that for 75 &degC conductor temperature per NFPA 79). Conductor temperatures not to exceed 105 &degC in dry locations when rated AWM and used as appliance wiring material or when used asT90 Nylon. Voltage for all applications is 600 volts.
$ 0.17 M
Qty:
add to cart
Part #:THHN 12BLUSOLCU4500
APPLICATIONS Southwire Type THHN or THWN-2 conductors are primarily used in conduit and cable trays for services, feeders, and branch circuits in commercial or industrial applications as specified in the 2008 National Electrical Code. When used as Type THHN, or T90 Nylon conductor is suitable for use in dry locations at temperatures not to exceed 90 &degC. When used as Type THWN-2 or TWN75, conductor is suitable for use in wet or dry locations at temperatures not to exceed 90 &degC or not to exceed 75 &degC when exposed to oil or coolant. When used as Type MTW, conductor is suitable for use in wet locations or when exposed to oil or coolant at temperatures not to exceed 60 &degC or dry locations at temperatures not to exceed 90 &degC (with ampacity limited to that for 75 &degC conductor temperature per NFPA 79). Conductor temperatures not to exceed 105 &degC in dry locations when rated AWM and used as appliance wiring material or when used asT90 Nylon. Voltage for all applications is 600 volts.
$ 0.19 M
Qty:
add to cart
Part #:THHN 12OE2500
APPLICATIONS Southwire Type THHN or THWN-2 conductors are primarily used in conduit and cable trays for services, feeders, and branch circuits in commercial or industrial applications as specified in the 2008 National Electrical Code. When used as Type THHN, or T90 Nylon conductor is suitable for use in dry locations at temperatures not to exceed 90 &degC. When used as Type THWN-2 or TWN75, conductor is suitable for use in wet or dry locations at temperatures not to exceed 90 &degC or not to exceed 75 &degC when exposed to oil or coolant. When used as Type MTW, conductor is suitable for use in wet locations or when exposed to oil or coolant at temperatures not to exceed 60 &degC or dry locations at temperatures not to exceed 90 &degC (with ampacity limited to that for 75 &degC conductor temperature per NFPA 79). Conductor temperatures not to exceed 105 &degC in dry locations when rated AWM and used as appliance wiring material or when used asT90 Nylon. Voltage for all applications is 600 volts.
$ 0.15 M
Qty:
add to cart
Part #:THHN 12RDS500
APPLICATIONS Southwire Type THHN or THWN-2 conductors are primarily used in conduit and cable trays for services, feeders, and branch circuits in commercial or industrial applications as specified in the 2008 National Electrical Code. When used as Type THHN, or T90 Nylon conductor is suitable for use in dry locations at temperatures not to exceed 90 &degC. When used as Type THWN-2 or TWN75, conductor is suitable for use in wet or dry locations at temperatures not to exceed 90 &degC or not to exceed 75 &degC when exposed to oil or coolant. When used as Type MTW, conductor is suitable for use in wet locations or when exposed to oil or coolant at temperatures not to exceed 60 &degC or dry locations at temperatures not to exceed 90 &degC (with ampacity limited to that for 75 &degC conductor temperature per NFPA 79). Conductor temperatures not to exceed 105 &degC in dry locations when rated AWM and used as appliance wiring material or when used asT90 Nylon. Voltage for all applications is 600 volts.
$ 0.17 M
Qty:
add to cart
closeout
Part #:THHN 12WES500
CLOSEOUTS Only 1500 Left!
APPLICATIONS Southwire Type THHN or THWN-2 conductors are primarily used in conduit and cable trays for services, feeders, and branch circuits in commercial or industrial applications as specified in the 2008 National Electrical Code. When used as Type THHN, or T90 Nylon conductor is suitable for use in dry locations at temperatures not to exceed 90 &degC. When used as Type THWN-2 or TWN75, conductor is suitable for use in wet or dry locations at temperatures not to exceed 90 &degC or not to exceed 75 &degC when exposed to oil or coolant. When used as Type MTW, conductor is suitable for use in wet locations or when exposed to oil or coolant at temperatures not to exceed 60 &degC or dry locations at temperatures not to exceed 90 &degC (with ampacity limited to that for 75 &degC conductor temperature per NFPA 79). Conductor temperatures not to exceed 105 &degC in dry locations when rated AWM and used as appliance wiring material or when used asT90 Nylon. Voltage for all applications is 600 volts.
$ 0.17 M
Qty:
add to cart
$ 1.13 M
Qty:
add to cart
$ 2.11 M
Qty:
add to cart
Part #:SJOW ASJO123BLK250S
SJOOW Flexible Portable Cord applications include portable tools and equipment, portable appliances, small motors and associated machinery. FeaturesExcellent resistance to oil and moisture. Good tensile strength, elongation and aging characteristics. High flexibility. Excellent abrasion resistance. Water-resistant. UL Listed and CSA Certified for indoor and outdoor use. Sunlight-resistant. Temperature range -40&ordmC to +90&ordmC StandardsUL Flexible Cord - UL Subject 62CSA Flexible Cord - C22.2-49MSHA ApprovedRoHS Compliant ConstructionConductors18 through 10 AWG fully annealed stranded bare copper per ASTM B-174InsulationPremium-grade, color-coded 90&ordmC EPDM. Specifications Size12 AWGNumber of Conductors3Conductor Strand65/30Insulation Thickness0.76 mm / 0.030 inchesOutside Diameter10.92 mm / 0.430 inchesWeight0.15 lbs per ftCurrent Amps25 Color Code3 Conductors Black, White, Green
$ 1.35 FT
Qty:
add to cart
Part #:SOOW ASOW123BLK250C
SOOW Flexible Cord applications include portable tools and equipment, portable appliances, small motors and associated machinery FeaturesExcellent resistance to oil and moisture. Good tensile strength, elongation and aging characteristics. High flexibility. Excellent abrasion resistance. Sunlight-resistant. UL Listed and CSA Certified for indoor and outdoor use. Temperature range -40&ordmC to +90&ordmC StandardsUL Flexible Cord - UL Subject 62CSA Flexible Cord - C22.2-49MSHA ApprovedRoHS Compliant ConstructionConductors18 through 2 AWG fully annealed stranded bare copper per ASTM B-174InsulationPremium-grade, color-coded 90&ordmC EPDM. Specifications Size12 AWGNumber of Conductors3Conductor Strand65/30Insulation Thickness0.045 inchesOutside Diameter0.595 inchesWeight0.223 lbs per ftCurrent Amps25 Color Code3 Conductors &ndash Black, White, Green
$ 2.27 M
Qty:
add to cart
Part #:SJOOW ASJOW124BLK25
SJOOW Flexible Portable Cord applications include portable tools and equipment, portable appliances, small motors and associated machinery. FeaturesExcellent resistance to oil and moisture. Good tensile strength, elongation and aging characteristics. High flexibility. Excellent abrasion resistance. Water-resistant. UL Listed and CSA Certified for indoor and outdoor use. Sunlight-resistant. Temperature range -40&ordmC to +90&ordmC StandardsUL Flexible Cord - UL Subject 62CSA Flexible Cord - C22.2-49MSHA ApprovedRoHS Compliant ConstructionConductors18 through 10 AWG fully annealed stranded bare copper per ASTM B-174InsulationPremium-grade, color-coded 90&ordmC EPDM. Specifications Size12 AWGNumber of Conductors4Conductor Strand65/30Insulation Thickness0.76 mm / 0.030 inchesOutside Diameter12.07 mm / 0.475 inchesWeight0.18 lbs per ftCurrent Amps20 Color Code4 Conductors Black, White, Red, Green
$ 4.48 M
Qty:
add to cart
$ 2.77 FT
Qty:
add to cart
Part #:EMERSON IC694TBB132
High Density 32 Point Terminal Block Box Style with Extended Shroud for Large Wiring Bundles
$ 91.00
Qty:
add to cart
Part #:MTW 14BE500
$ 0.33 M
Qty:
add to cart
Part #:MTW 14BK2500
14 AWG MTW Stranded Wire, 600V Type conductors are primarily used in control cabinets, in machine tool applications and appliance wiring applications. Applications requiring Type MTW conductor is appropriate for use in dry locations at 90&degC, or not to exceed 60&degC in wet locations or where exposed to oils or coolants. Applications requiring Type AWM conductor is appropriate for use at temperatures to not exceed 105&degC in dry locations. Bare Copper StrandingE315270 14 AWG (UL) MTW OR THHW OR BC-5W2 OR AWM 1011/1015/1230/1335 600V OR 1032/10269 1000V, VW-1---240954 CSA TEW 600V OR AWM 1 A/B 105C 1000V FT-1---SAE J1128 TYPE GPT Specifications Size14 AWGNumber of Strands19 or 41Temp105&degCInsulation Thickness0.030 inchesOutside Diameter0.132 inchesVoltage600V
$ 0.32 M
Qty:
add to cart
 
Displaying: 97 - 120 of 258 Matching Items