Automation Controllers
All in One Controllers
View:
Active Filters :
- Main Category: All in One Controllers Automation Controllers Generators Wire
Part #:MTW 18BK2500
- 18 AWG MTW/UL1015 Hook-Up Stranded Wire, 600V.
18 AWG UL1015Type conductors are primarily used in control cabinets, in machine tool applications and appliance wiring applications. Applications requiring Type MTW conductor is appropriate for use in dry locations at 90°C, or not to exceed 60°C in wet locations or where exposed to oils or coolants. Applications requiring Type AWM conductor is appropriate for use at temperatures to not exceed 105°C in dry locations.ConductorBare Copper
InsulationPolyvinyl Chloride (PVC)StandardsUL recognized AWM Style 1015 per 758. Passes VW-1 vertical flame test. CSA TEW or AWM
Specifications
Size18 AWGNumber of Strands16Temp105°CInsulation Thickness0.031 inchesOutside Diameter0.11 inchesWeight0.010 lbs per ftVoltage600V
$
0.14
M
Qty:
Part #:MTW 18WE2500
- 18 AWG MTW/UL1015 Hook-Up Stranded Wire, 600V.
18 AWG UL1015Type conductors are primarily used in control cabinets, in machine tool applications and appliance wiring applications. Applications requiring Type MTW conductor is appropriate for use in dry locations at 90°C, or not to exceed 60°C in wet locations or where exposed to oils or coolants. Applications requiring Type AWM conductor is appropriate for use at temperatures to not exceed 105°C in dry locations.ConductorBare Copper
InsulationPolyvinyl Chloride (PVC)StandardsUL recognized AWM Style 1015 per 758. Passes VW-1 vertical flame test. CSA TEW or AWM
Specifications
Size18 AWGNumber of Strands16Temp105°CInsulation Thickness0.031 inchesOutside Diameter0.11 inchesWeight0.010 lbs per ftVoltage600V
$
0.16
M
Qty:
Part #:SJ 183BLK250SP
- 18/3 SJOOW Flexible Portable Cord applications include portable tools and equipment, portable appliances, small motors and associated machinery.
FeaturesExcellent resistance to oil and moisture. Good tensile strength, elongation and aging characteristics. High flexibility. Excellent abrasion resistance. Water-resistant. UL Listed and CSA Certified for indoor and outdoor use. Sunlight-resistant. Temperature range -40ºC to +90ºC
StandardsUL Flexible Cord - UL Subject 62CSA Flexible Cord - C22.2-49MSHA ApprovedRoHS Compliant
ConstructionConductors18 through 10 AWG fully annealed stranded bare copper per ASTM B-174InsulationPremium-grade, color-coded 90ºC EPDM.
Specifications
Size18 AWGNumber of Conductors3Conductor Strand16/30Insulation Thickness0.76 mm / 0.030 inchesOutside Diameter7.75 mm / 0.305 inchesWeight0.065 lbs per ftCurrent Amps10
Color Code3 Conductors Black, White, Green
Also Known As18/3 SJ cord, 18/3 wire, 18 gauge 3 wire flexible cord, 18/3 oil-resistant outdoor cable
$
0.51
M
Qty:
Part #:TFFN 18BK500
- Southwire® Type TFFN or MTW or AWM may be used as fixture wire, machine tool wiring,or appliance wiring material as specified in the National Electrical Code. Voltage for allapplications is 600 volts. Allowable temperatures are as follows&bull TFFN- Dry locations not to exceed 90°C&bull MTW- Wet locations or when exposed to oil or coolant at temperatures not to exceed60°C&bull MTW- Dry locations at Temperatures not to exceed 90°C (with ampacity limited tothat for 75°C conductor temperature per NFPA 79)&bull AWM- When rated as appliance wiring material in dry locations, conductortemperatures not to exceed 105°C&bull TEWN- Wet or dry locations conductor temperatures not to exceed 105°C
$
0.08
M
Qty:
Part #:TFFN 18WE500
- Southwire® Type TFFN or MTW or AWM may be used as fixture wire, machine tool wiring,or appliance wiring material as specified in the National Electrical Code. Voltage for allapplications is 600 volts. Allowable temperatures are as follows&bull TFFN- Dry locations not to exceed 90°C&bull MTW- Wet locations or when exposed to oil or coolant at temperatures not to exceed60°C&bull MTW- Dry locations at Temperatures not to exceed 90°C (with ampacity limited tothat for 75°C conductor temperature per NFPA 79)&bull AWM- When rated as appliance wiring material in dry locations, conductortemperatures not to exceed 105°C&bull TEWN- Wet or dry locations conductor temperatures not to exceed 105°C
$
0.07
M
Qty:
$
3.43
M
Qty:
Part #:EMERSON IC200ALG620
- VersaMax Analog Input Module, 16 Bit RTD, 4 Channel
RTD and Thermocouple Modules Specialty modules are available for RTD and Thermocouple inputs. Modules require a carrier base(IC200CHSxxx).
$
764.00
Qty:
closeout
Part #:EMERSON IC200MDL240
- Availability: Out of stock
- VersaMax Discrete Input Module, 120 VAC Positive Logic, 16 points
Discrete Input Modules Discrete input modules receive signals from input devices such as sensors, pushbuttons, and switchesthat can have two states on or off, open or closed. Modules require a carrier base (IC200CHSxxx).
$
359.00
Qty:
Part #:EMERSON IC200MDL640
- VersaMax Discrete InputModule, 24 VDCPos/Neg Logic, 16 points
Discrete Input Modules Discrete input modules receive signals from input devices such as sensors, pushbuttons, and switchesthat can have two states on or off, open or closed. Modules require a carrier base (IC200CHSxxx).
$
228.00
Qty:
Part #:EMERSON IC200MDL742
- VersaMax Discrete Output Module, 24 VDC Positive Logic 0.5A with ESCP, 32 points
Discrete Output Modules Discrete output modules send control signals to devices such as contactors, indicator lamps, andinterposing relays that can also have two states. Modules require a carrier base (IC200CHSxxx).
$
619.00
Qty:
$
2,586.94
Qty:
Part #:HOR HE800DAC202
- Description
MetalSmartStack I/O can only be stacked directly on the back of products supporting metal encased I/O models, such as Classic OCS, RCS, RX ruggedized controller, and Metal FOX. Products are sorted by commonality. All SmartStack I/O modules include spring-clamp style removable terminals except where noted.
$
1,229.00
Qty:
$
2.71
FT
Qty:
$
2.32
FOOT
Qty:
$
0.40
FT
Qty:
Part #:SOU 20493301
- THHN, THWN-2, MTW, AWM TYPE 500 FT 500 LENGTH IN FT 249 MIL OUTER DIAMETER ANNEALED COPPER CONDUCTOR MATERIAL UL 83, UL 1063, UL 1581, UL (CANADA AND US), CSA APPROVAL 600 V VOLTAGE RATING 55 AMPERE (60 DEG C), 65 AMPERE (75 DEG C), 75 AMPERE (90 DEG C) CURRENT RATING 90 DEG C TEMPERATURE RATING 95 LB/MFT WEIGHT PVC INSULATION MATERIAL 6 AWG CONDUCTOR SIZE NYLON JACKET MATERIAL SPOOL PACKAGE TYPE 19 STRANDS STRANDING BLACK INSULATION COLOR NOLUBE[T], SIM TECHNOLOGY[R] BRAND
$
1.42
M
Qty:
Part #:HOR HE800THM100
- Description
MetalSmartStack I/O can only be stacked directly on the back of products supporting metal encased I/O models, such as Classic OCS, RCS, RX ruggedized controller, and Metal FOX. Products are sorted by commonality. All SmartStack I/O modules include spring-clamp style removable terminals except where noted.
$
792.00
Qty:
Part #:MTW 22BE500
$
0.09
M
Qty:
closeout
Part #:EMERSON IC693ALG221
- CLOSEOUTS Only 4 Left!
- Analog Input, Current, 4 Channel
Analog I/O Modules (Input) GE offers easy-to-use analog modules for control processes such as flow, temperatureand pressure.
$
2,475.00
Qty:
Part #:THHN 500BK500
- APPLICATIONS
Southwire Type THHN or THWN-2 conductors are primarily used in conduit and cable trays for services, feeders, and branch circuits in commercial or industrial applications as specified in the 2008 National Electrical Code. When used as Type THHN, or T90 Nylon conductor is suitable for use in dry locations at temperatures not to exceed 90 °C. When used as Type THWN-2 or TWN75, conductor is suitable for use in wet or dry locations at temperatures not to exceed 90 °C or not to exceed 75 °C when exposed to oil or coolant. When used as Type MTW, conductor is suitable for use in wet locations or when exposed to oil or coolant at temperatures not to exceed 60 °C or dry locations at temperatures not to exceed 90 °C (with ampacity limited to that for 75 °C conductor temperature per NFPA 79). Conductor temperatures not to exceed 105 °C in dry locations when rated AWM and used as appliance wiring material or when used asT90 Nylon. Voltage for all applications is 600 volts.
$
17.76
M
Qty:
Part #:EMERSON IC694ALG223
- PACSystems RX3iAnalog Input, Input,Current, High Density(16 Channel)
Analog I/O Modules (Input) GE offers easy-to-use analog modules and HART analog modules for control processes such asflow, temperature and pressure.
$
1,474.00
Qty:
Part #:SEU 224AL500R
- Aluminum SEU cable is primarily used as panel feeder in multiple unit dwellings and for branch circuits. Maximum operating temperature is not to exceed 90°C in wet locations. Voltage rating is 600 volts.
ConstructionConductor - Aluminum SEU cable has a compact strand soft drawn 8000 series aluminum conductor, per ASTM B-801
Insulation - Aluminum SEU cable has a type XHHW-2 cross linked polyethylene (XLP) insulation. The conductors are cabled together with an aluminum alloy concentric neutral and covered with a reinforced binder tape.
Jacket - Aluminum SEU cable has a gray sunlight resistance polyvinyl chloride (PVC) jacket.
StandardsUL 44, 854Federal Specification J-C - 30BAmpacities based on National Electric Code, 2005 edition, section 310-1560°C when terminated to equipment for circuits rated 100amps or less or marked for 14ga through 1ga conductors70°C when terminated to equipment for circuits rated over 100amps or marked for conductors larger than 1ga90°C wet or dry locations For dwelling units, conductors shall be permitted at listed Ampacities to be utilized as 120/240 volt, 3-wire, single phase service conductors that supply the total load
Specifications
Insulated Conductor Size2 AWGBare Neutral Size2 AWGOutside Diameter0.566inchesAmpacity100 amps @90°CNet Weight.259 lbs/ft
$
1.74
M
Qty:
Part #:SOU 22955901
- THHN, THWN, MTW, AWM TYPE 500 FT 500 LENGTH IN FT 109 MIL OUTER DIAMETER ANNEALED COPPER CONDUCTOR MATERIAL UL 83, UL 1063, UL 1581, UL (CANADA AND US), CSA APPROVAL 600 V VOLTAGE RATING 15 AMPERE CURRENT RATING 90 DEG C TEMPERATURE RATING 16 LB/MFT WEIGHT PVC INSULATION MATERIAL 14 AWG CONDUCTOR SIZE NYLON JACKET MATERIAL SPOOL PACKAGE TYPE 19 STRANDS STRANDING BLACK INSULATION COLOR NOLUBE[T], SIM TECHNOLOGY[R] BRAND
$
0.26
M
Qty:
Part #:SOU 22956701
- THHN, THWN, MTW, AWM TYPE 500 FT 500 LENGTH IN FT 109 MIL OUTER DIAMETER ANNEALED COPPER CONDUCTOR MATERIAL UL 83, UL 1063, UL 1581, UL (CANADA AND US), CSA APPROVAL 600 V VOLTAGE RATING 15 AMPERE CURRENT RATING 90 DEG C TEMPERATURE RATING 16 LB/MFT WEIGHT PVC INSULATION MATERIAL 14 AWG CONDUCTOR SIZE NYLON JACKET MATERIAL SPOOL PACKAGE TYPE 19 STRANDS STRANDING WHITE INSULATION COLOR NOLUBE[T], SIM TECHNOLOGY[R] BRAND
$
0.17
M
Qty:
Displaying: 145 - 168 of 258 Matching Items