Part #:BUSS LPS-RK-50SP

CLASS RK1 TYPE 5.5 INCH UL 248-12, CSA C22.2, CE APPROVAL 600 VOLT AC, 300 VOLT DC VOLTAGE RATING 1.06 INCH DIAMETER 300 KILOAMP SYMMETRICAL, 100 KILOAMP (DC) INTERRUPTING RATING 50 AMP CURRENT RATING FERRULE WITH GROOVED RING TERMINAL TYPE 10 SECOND TIME DELAY AT 500 PERCENT RATED LOAD, DUAL ELEMENT, NON-INDICATING CHARACTERISTICS LOW-PEAK[TM] BRAND CONTACT MATERIAL SILVER PLATED APPLICATION LARGE DISTRIBUTION SWITCHBOARD, POWER PANELBOARD, MOTOR CONTROL CENTER, MACHINERY DISCONNECT SWITCH LPS-RK MODEL
$ 106.36
Part #:STL-CTY HC405

THREADLESS COMPRESSION TYPE STEEL MATERIAL RIGID/IMC CONDUIT USED ON UL 514-B APPROVAL 30 STANDARD PACKAGE 1-1/2 INCH TRADE SIZE APPLICABLE STANDARD FEDERAL SPECIFICATION A-A-50552/A-A-50553/WC-586, NEMA FB 1 HC MODEL
$ 92.51
C
Part #:STL-CTY 503SC

I TYPE MALLEABLE IRON MATERIAL SILVER ELECTROPLATED FINISH 1 INCH MAX. JAW CAPACITY HANGING ROD APPLICATION 1300 LB LOAD CAPACITY 1/2 INCH-13 TPI SCREW SIZE SQUARE HEAD SCREW TYPE YES SUPPLIED WITH SCREW APPROVAL CSA BASE SIZE 2-1/2 INCH L X 2-5/8 INCH W
$ 32.46
C
Part #:STL-CTY HC402

THREADLESS COMPRESSION TYPE STEEL MATERIAL RIGID/IMC CONDUIT USED ON UL 514-B APPROVAL 25 STANDARD PACKAGE 3/4 INCH TRADE SIZE APPLICABLE STANDARD FEDERAL SPECIFICATION A-A-50552/A-A-50553/WC-586, NEMA FB 1 HC MODEL
$ 17.92
C
Part #:GE THQB1115

MOLDED CASE, FIXED THERMAL MAGNETIC TYPE 1 INCH WIDTH X 2-3/8 INCH DEPTH X 3-9/32 INCH HEIGHT SIZE AQ SERIES PANELBOARD USED ON 14 TO 8 AWG (COPPER), 12 TO 8 AWG (ALUMINUM) WIRE SIZE UL APPROVAL 120/240 VOLT AC VOLTAGE RATING 1 INCH BOLT-ON MOUNTING 10 KILOAMP INTERRUPTING RATING 15 AMP CURRENT RATING 1 POLE(S) COPPER/ALUMINUM LOAD LUG TERMINAL TYPE TRIP TYPE NON-INTERCHANGEABLE FRAME TYPE THQB TRIP FUNCTION LI APPLICATION HEATING, AIR CONDITIONING, REFRIGERATION THQB MODEL
$ 35.00
Part #:GE THQB1120

MOLDED CASE, FIXED THERMAL MAGNETIC TYPE 1 INCH WIDTH X 2-3/8 INCH DEPTH X 3-9/32 INCH HEIGHT SIZE AQ SERIES PANELBOARD USED ON 14 TO 8 AWG (COPPER), 12 TO 8 AWG (ALUMINUM) WIRE SIZE UL APPROVAL 120/240 VOLT AC VOLTAGE RATING 1 INCH BOLT-ON MOUNTING 10 KILOAMP INTERRUPTING RATING 20 AMP CURRENT RATING 1 POLE(S) COPPER/ALUMINUM LOAD LUG TERMINAL TYPE TRIP TYPE NON-INTERCHANGEABLE FRAME TYPE THQB TRIP FUNCTION LI APPLICATION HEATING, AIR CONDITIONING, REFRIGERATION THQB MODEL
$ 35.00
Part #:GE THQB2115

MOLDED CASE, FIXED THERMAL MAGNETIC, INTERNAL COMMON TRIP TYPE 2 INCH W X 2-3/8 INCH D X 3-9/32 INCH H SIZE AQ SERIES PANELBOARD USED ON 14 TO 8 AWG (COPPER)/12 TO 8 AWG (ALUMINUM) WIRE SIZE UL APPROVAL 120/240 VAC VOLTAGE RATING 1 INCH BOLT-ON MOUNTING 10 KILOAMPERE INTERRUPTING RATING 15 AMPERE CURRENT RATING 2 POLE(S) COPPER/ALUMINUM LOAD LUG, BOLT-ON TERMINAL TYPE TRIP TYPE NON-INTERCHANGEABLE FRAME TYPE THQB TRIP FUNCTION LI APPLICATION HEATING, AIR CONDITIONING, REFRIGERATION SERIES THQB MODEL
$ 78.00
Part #:GE THQB2150

MOLDED CASE, FIXED THERMAL MAGNETIC, INTERNAL COMMON TRIP TYPE 2 INCH W X 2-3/8 INCH D X 3-9/32 INCH H SIZE AQ SERIES PANELBOARD USED ON 8 TO 3 AWG (COPPER/ALUMINUM) WIRE SIZE UL APPROVAL 120/240 VAC VOLTAGE RATING 1 INCH BOLT-ON MOUNTING 10 KILOAMPERE INTERRUPTING RATING 50 AMPERE CURRENT RATING 2 POLE(S) COPPER/ALUMINUM LOAD LUG, BOLT-ON TERMINAL TYPE TRIP TYPE NON-INTERCHANGEABLE FRAME TYPE THQB TRIP FUNCTION LI APPLICATION HEATING, AIR CONDITIONING, REFRIGERATION SERIES THQB MODEL
$ 78.00
Part #:GE THQB2120

MOLDED CASE, FIXED THERMAL MAGNETIC, INTERNAL COMMON TRIP TYPE 2 INCH WIDTH X 2-3/8 INCH DEPTH X 3-9/32 INCH HEIGHT SIZE AQ SERIES PANELBOARD USED ON 14 TO 8 AWG (COPPER), 12 TO 8 AWG (ALUMINUM) WIRE SIZE UL APPROVAL 120/240 VOLT AC VOLTAGE RATING 1 INCH BOLT-ON MOUNTING 10 KILOAMP INTERRUPTING RATING 20 AMP CURRENT RATING 2 POLE(S) COPPER/ALUMINUM LOAD LUG TERMINAL TYPE TRIP TYPE NON-INTERCHANGEABLE FRAME TYPE THQB TRIP FUNCTION LI APPLICATION HEATING, AIR CONDITIONING, REFRIGERATION THQB MODEL
$ 78.00
Part #:GE THQB2160

MOLDED CASE, FIXED THERMAL MAGNETIC, INTERNAL COMMON TRIP TYPE 2 INCH WIDTH X 2-3/8 INCH DEPTH X 3-9/32 INCH HEIGHT SIZE AQ SERIES PANELBOARD USED ON 8 TO 3 AWG (COPPER/ALUMINUM) WIRE SIZE UL APPROVAL 120/240 VOLT AC VOLTAGE RATING 1 INCH BOLT-ON MOUNTING 10 KILOAMP INTERRUPTING RATING 60 AMP CURRENT RATING 2 POLE(S) COPPER/ALUMINUM LOAD LUG TERMINAL TYPE TRIP TYPE NON-INTERCHANGEABLE FRAME TYPE THQB TRIP FUNCTION LI APPLICATION HEATING, AIR CONDITIONING, REFRIGERATION THQB MODEL
$ 78.00
Part #:STL-CTY HC404

THREADLESS COMPRESSION TYPE STEEL MATERIAL RIGID/IMC CONDUIT USED ON UL 514-B APPROVAL 60 STANDARD PACKAGE 1-1/4 INCH TRADE SIZE APPLICABLE STANDARD FEDERAL SPECIFICATION A-A-50552/A-A-50553/WC-586, NEMA FB 1 HC MODEL
$ 67.01
C
Part #:STL-CTY HC406

COMPRESSION, THREADLESS TYPE MALLEABLE IRON MATERIAL IMC/RIGID CONDUIT USED ON UL 514B APPROVAL 12 PER CARTON STANDARD PACKAGE 2 INCH TRADE SIZE APPLICABLE STANDARD FEDERAL SPECIFICATION A-A-50552/A-A-50553/WC-586, NEMA FB-1 SERIES HC MODEL
$ 127.90
C
Part #:BUSS LPS-RK-200SP

CLASS RK1 TYPE 9.63 INCH UL 248-12, CSA C22.2, CE APPROVAL 600 VAC/300 VDC VOLTAGE RATING 1.66 INCH DIAMETER 300 KILOAMPERE (SYMMETRICAL), 100 KILOAMPERE (DC) INTERRUPTING RATING 200 AMPERE CURRENT RATING BLADE TERMINAL TYPE 10 SEC TIME DELAY (AT 500 PERCENT RATED LOAD), DUAL ELEMENT, NON-INDICATING CHARACTERISTICS LOW-PEAK[TM] BRAND APPLICATION LARGE DISTRIBUTION SWITCHBOARD, POWER PANELBOARD, MOTOR CONTROL CENTER, MACHINERY DISCONNECT SWITCH SERIES LPS-RK MODEL
$ 535.94
Part #:BUSS LPS-RK-25SP

CLASS RK1 TYPE 5 INCH UL 248-12, CSA C22.2, CE APPROVAL 600 VAC/300 VDC VOLTAGE RATING 0.81 INCH DIAMETER 300 KILOAMPERE (SYMMETRICAL), 100 KILOAMPERE (DC) INTERRUPTING RATING 25 AMPERE CURRENT RATING FERRULE WITH GROOVED RING TERMINAL TYPE 8 SEC TIME DELAY (AT 500 PERCENT RATED LOAD), DUAL ELEMENT, NON-INDICATING CHARACTERISTICS LOW-PEAK[TM] BRAND APPLICATION LARGE DISTRIBUTION SWITCHBOARD, POWER PANELBOARD, MOTOR CONTROL CENTER, MACHINERY DISCONNECT SWITCH SERIES LPS-RK MODEL
$ 75.26
Part #:BUSS LPS-RK-30SP

CLASS RK1 TYPE 5 INCH UL 248-12, CSA C22.2, CE APPROVAL 600 VAC/300 VDC VOLTAGE RATING 0.81 INCH DIAMETER 300 KILOAMPERE (SYMMETRICAL), 100 KILOAMPERE (DC) INTERRUPTING RATING 30 AMPERE CURRENT RATING FERRULE WITH GROOVED RING TERMINAL TYPE 8 SEC TIME DELAY (AT 500 PERCENT RATED LOAD), DUAL ELEMENT, NON-INDICATING CHARACTERISTICS LOW-PEAK[TM] BRAND APPLICATION LARGE DISTRIBUTION SWITCHBOARD, POWER PANELBOARD, MOTOR CONTROL CENTER, MACHINERY DISCONNECT SWITCH SERIES LPS-RK MODEL