Ceramic Tube
5 Day With Week Schedule


Displaying: 1 - 24 of 46 Matching Items
46 Items
View:
Part #:BUSS MDA-6

MINIATURE CERAMIC TUBE TYPE 1-1/4 INCH UL 248-14, CSA, CE APPROVAL 250 VAC VOLTAGE RATING 1/4 INCH DIAMETER 200 AMPERE AT 250 VAC, 10000 AMPERE AT 125 VAC INTERRUPTING RATING 6 AMPERE CURRENT RATING FERRULE TERMINAL TYPE TIME DELAY CHARACTERISTICS MDA MODEL
$ 6.22
Part #:INT-MAT EH10

5 DAY WITH WEEK SCHEDULE TYPE DRAWN STEEL MATERIAL 5 INCH W X 3 INCH D X 7 3/4 INCH H SIZE GRAY FINISH 6 MAX. NUMBER OF OPERATIONS UL 916 APPROVAL WATER HEATER APPLICATION 120 VAC AT 50/60 HZ VOLTAGE RATING WALL MOUNTING 30 AMPERE AT 120 VAC (RESISTIVE/INDUCTIVE), 5 AMPERE AT 120 VAC (TUNGSTEN) CURRENT RATING 1 HP AT 120 VAC, 3600 W POWER RATING -40 T0 104 DEG F OPERATING TEMPERATURE SPST SWITCH TYPE ALKALINE BATTERY 3 YEAR RESERVE POWER INTERMATIC[R] BRAND WITH MANUAL EXTERNAL OVERRIDE, LOAD INDICATOR
$ 203.98
Part #:INT-MAT EH40

5 DAY WITH WEEK SCHEDULE TYPE DRAWN STEEL MATERIAL 5 INCH W X 3 INCH D X 7 3/4 INCH H SIZE GRAY FINISH 6 MAX. NUMBER OF OPERATIONS UL 916 APPROVAL WATER HEATER APPLICATION 240 VAC AT 50/60 HZ VOLTAGE RATING WALL MOUNTING 30 AMPERE AT 240 VAC (RESISTIVE/INDUCTIVE), 5 AMPERE AT 240 VAC (TUNGSTEN) CURRENT RATING 1 1/2 HP AT 240 VAC, 7200 W POWER RATING -40 T0 104 DEG F OPERATING TEMPERATURE DPST SWITCH TYPE ALKALINE BATTERY 3 YEAR RESERVE POWER INTERMATIC[R] BRAND WITH MANUAL EXTERNAL OVERRIDE, LOAD INDICATOR
$ 243.74
Part #:SIEM5 Q115

MINIATURE, THERMAL AND FIXED MAGNETIC TRIP TYPE 1 INCH WIDTH X 3 INCH DEPTH X 3-1/8 INCH HEIGHT SIZE LOAD CENTER USED ON 14 TO 6 AWG (COPPER/ALUMINUM) WIRE SIZE UL 489 APPROVAL 120 VOLT AC VOLTAGE RATING PLUG-IN MOUNTING 10 KILOAMP INTERRUPTING RATING 15 AMP AT 40 DEG C CURRENT RATING 1 POLE(S) LOAD LUG TERMINAL TYPE SPEEDFAX[TM], INSTA-WIRE BRAND FRAME TYPE QP QP MODEL
$ 78.72
Part #:SIEM5 Q230

MINIATURE, THERMAL AND FIXED MAGNETIC TRIP, COMMON TRIP TYPE 2 INCH WIDTH X 3 INCH DEPTH X 3-1/8 INCH HEIGHT SIZE LOAD CENTER USED ON 14 TO 6 AWG (COPPER/ALUMINUM) WIRE SIZE UL 489 APPROVAL 120/240 VOLT AC VOLTAGE RATING PLUG-IN MOUNTING 10 KILOAMP INTERRUPTING RATING 30 AMP AT 40 DEG C CURRENT RATING 2 POLE(S) LOAD LUG TERMINAL TYPE SPEEDFAX[TM], INSTA-WIRE BRAND FRAME TYPE QP QP MODEL
$ 161.14
Part #:GE EP101ULH3C01

Circuit Breaker, 1 Pole, C-Curve, 1A, UL489, 277V 10kA, 480Y/277VAC, 60/125VDC EP100 UL UL1077 10kA C trip curves 277/480VAC, 50/110VDC
$ 122.00
Part #:BUR TP1010FBG25

SMOOTH ENTRY TYPE YELLOW COLOR 12 AWG MIN. CONDUCTOR SIZE 10 AWG MAX. CONDUCTOR SIZE UL, CSA APPROVAL 25 PER BAG STANDARD PACKAGE #8 TO #10 STUD SIZE VINYL INSULATED INSULATION TYPE ROHS COMPATIBLE DIMENSION 1.07 INCH L X 0.41 INCH W VOLTAGE RATING 600 V MATERIAL ELECTROLYTIC TIN PLATED COPPER
$ 9.00
Part #:BUR TP108FBG25

SMOOTH ENTRY TYPE YELLOW COLOR 12 AWG MIN. CONDUCTOR SIZE 10 AWG MAX. CONDUCTOR SIZE UL, CSA APPROVAL 25 PER BAG STANDARD PACKAGE #6 TO #8 STUD SIZE VINYL INSULATED INSULATION TYPE ROHS COMPATIBLE DIMENSION 0.98 INCH L X 0.31 INCH W VOLTAGE RATING 600 V MATERIAL ELECTRO TIN PLATED COPPER
$ 9.00
Part #:GE THQL1115AF

FIXED THERMAL MAGNETIC TYPE 1 INCH W X 2-3/8 INCH D X 3-9/32 INCH H SIZE AL/ALC SERIES PANELBOARD, RESIDENTIAL LOADCENTER USED ON 14 TO 10 AWG (COPPER/ALUMINUM) WIRE SIZE UL APPROVAL 120/240 VAC VOLTAGE RATING 1 INCH PLUG-IN MOUNTING 10 KILOAMPERE INTERRUPTING RATING 15 AMPERE CURRENT RATING 1 POLES ARC FAULT CIRCUIT INTERRUPTER CONSTRUCTION FEATURE TRIP TYPE NON-INTERCHANGEABLE FRAME TYPE THQL TRIP FUNCTION LI SERIES THQL MODEL
$ 179.00
Part #:GE THQL1120AF

FIXED THERMAL MAGNETIC TYPE 1 INCH W X 2-3/8 INCH D X 3-9/32 INCH H SIZE AL/ALC SERIES PANELBOARD, RESIDENTIAL LOADCENTER USED ON 14 TO 10 AWG (COPPER/ALUMINUM) WIRE SIZE UL APPROVAL 120/240 VAC VOLTAGE RATING 1 INCH PLUG-IN MOUNTING 10 KILOAMPERE INTERRUPTING RATING 20 AMPERE CURRENT RATING 1 POLES ARC FAULT CIRCUIT INTERRUPTER CONSTRUCTION FEATURE BUYLOG[TM] BRAND TRIP TYPE NON-INTERCHANGEABLE FRAME TYPE THQL TRIP FUNCTION LI THQL MODEL
$ 179.00
Part #:SIEM5 Q290

MINIATURE, THERMAL AND FIXED MAGNETIC TRIP, COMMON TRIP TYPE 2 INCH WIDTH X 3 INCH DEPTH X 3-1/8 INCH HEIGHT SIZE LOAD CENTER USED ON 8 TO 2/0 AWG (COPPER/ALUMINUM) WIRE SIZE UL 489 APPROVAL 120/240 VOLT AC VOLTAGE RATING PLUG-IN MOUNTING 10 KILOAMP INTERRUPTING RATING 90 AMP AT 40 DEG C CURRENT RATING 2 POLE(S) LOAD LUG TERMINAL TYPE SPEEDFAX[TM], INSTA-WIRE BRAND FRAME TYPE QP QP MODEL
$ 470.68
Part #:SIEM5 Q1515NC

MINIATURE, THERMAL AND FIXED MAGNETIC TRIP, DUPLEX TYPE 1 INCH WIDTH X 2.06 INCH DEPTH X 3.12 INCH HEIGHT SIZE LOAD CENTER USED ON 14 TO 6 AWG (COPPER/ALUMINUM) WIRE SIZE UL 489 APPROVAL 120 VOLT AC VOLTAGE RATING PLUG-IN MOUNTING 10 KILOAMP INTERRUPTING RATING 15 AMP CURRENT RATING 1 POLE(S) LOAD LUG TERMINAL TYPE SPEEDFAX[TM] BRAND FRAME TYPE QT APPLICATION HEATING, AIR CONDITIONING, REFRIGERATION QT MODEL
$ 282.08
Part #:SIEM5 B120H

MOLDED CASE, THERMAL AND FIXED MAGNETIC, BRANCH TYPE P1/P2/P3/P4/P5 PANELBOARD USED ON BOLT-ON INSTALLATION UL 489, CSA C22.2 APPROVAL LIGHTING, DISTRIBUTION APPLICATION 120 VOLT AC AT 50/60 HERTZ VOLTAGE RATING 22 KILOAMP AT 120 VOLT AC INTERRUPTING RATING 20 AMP AT 40 DEG C CURRENT RATING 1 POLE(S) SPEEDFAX[TM] BRAND FRAME TYPE BLH TERMINAL TYPE BOLT-ON OVERALL DIMENSION 1 INCH WIDTH X 3 INCH DEPTH X 3-9/16 INCH HEIGHT
$ 204.48
Part #:SIEM5 ECCS1

14 TO 1/0 AWG (COPPER/ALUMINUM) COLLAR STRAP TYPE LOAD CENTER GROUND BAR USED ON DEPTH 248.2 INCH APPLICATION RESIDENTIAL
$ 18.82
Part #:SIEM6 QF115A

CIRCUIT PROTECTOR TYPE LOADCENTER USED ON 120 VAC VOLTAGE RATING PLUG-IN MOUNTING 10 KILOAMPERE INTERRUPTING RATING 15 AMPERE CURRENT RATING 1 POLE(S) 5 MILLIAMPERE TRIP SENSITIVITY
$ 405.40
Part #:SIEM5 ECGB10

ULTIMATE LOAD CENTER USED ON COPPER/ALUMINUM CONDUCTOR MATERIAL 10-TERMINAL (14 TO 4 AWG) TERMINAL SIZE SPEEDFAX[TM] BRAND
$ 60.04
closeout
Part #:GE IC695CRH003

CLOSEOUTS Only 1 Left!
90-70 MDL250 to RX3i MDL260 Harness Assembly.
$ 188.00
Part #:EMERSON IC694ACC310

GE IC694ACC310 Filler Module, Blank Slot, PACSystems RX3i
$ 58.00
Part #:EMERSON IC694ALG223

PACSystems RX3iAnalog Input, Input,Current, High Density(16 Channel) Analog I/O Modules (Input) GE offers easy-to-use analog modules and HART analog modules for control processes such asflow, temperature and pressure.
$ 1,307.00
Part #:EMERSON IC694ALG392

PACSystems RX3i Analog Output,Current/Voltage, 8 Channel Analog I/O Modules (Output) GE offers easy-to-use analog modules for control processes such as flow, temperatureand pressure.
$ 1,536.00
Part #:EMERSON IC694TBB132

High Density 32 Point Terminal Block Box Style with Extended Shroud for Large Wiring Bundles
$ 81.00
Part #:EMERSON IC695ACC402

$ 545.00
Part #:EMERSON IC695ACC600

RX3i Cold Junction Compensation Kit \ for Universal Analog Input IC695ALG600 and Thermocouple Input IC695ALG312, IC695ALG412 Modules
$ 151.00
Part #:EMERSON IC695ALG312

Isolated Thermocouple Input module provides twelve isolateddifferential thermocouple input channels. Each channel canbe individually configured for inputs from Thermocouple typesJ, K, T, E, R, S, B, N, or C and Voltage &plusmn150mV or &plusmn50mV. Millivolt I/O Modules The Millivolt Input Modules allow Millivolt level signals, such as bridged strain gages(load cells) to be directly connected to the PLC without external signal processing(transducers, transmitters, etc.) All analog and digital processing of the signal isperformed on the module.
$ 3,465.00
 
Displaying: 1 - 24 of 46 Matching Items