Frs-R
4436


Displaying: 1 - 21 of 21 Matching Items
21 Items
View:
Active Filters :
Part #:BUSS FRS-R-300
CLASS RK5 TYPE 11.63 INCH UL 248-12, CSA C22.2, CE APPROVAL 600 VOLT AC, 300 VOLT DC VOLTAGE RATING 2.34 INCH DIAMETER 200 KILOAMP SYMMETRICAL (AC), 20 KILOAMP (DC) INTERRUPTING RATING 300 AMP CURRENT RATING BLADE TERMINAL TYPE 10 SECOND TIME DELAY AT 500 PERCENT RATED LOAD, DUAL ELEMENT, NON-INDICATING CHARACTERISTICS FUSETRON[TM] BRAND APPLICATION POWER PANELBOARD, MOTOR CONTROL CENTER, COMBINATION STARTER, MACHINERY DISCONNECT FRS-R MODEL
$ 707.80
Qty:
add to cart
Part #:BUSS FRS-R-3
CLASS RK5 TYPE 5 INCH UL 248-12, CSA C22.2, CE APPROVAL 600 VAC/300 VDC VOLTAGE RATING 0.81 INCH DIAMETER 200 KILOAMPERE (SYMMETRICAL), 20 KILOAMPERE (DC) INTERRUPTING RATING 3 AMPERE CURRENT RATING FERRULE WITH GROOVED RING TERMINAL TYPE 10 SEC TIME DELAY (AT 500 PERCENT RATED LOAD), DUAL ELEMENT, NON-INDICATING CHARACTERISTICS FUSETRON[TM] BRAND APPLICATION POWER PANELBOARD, MOTOR CONTROL CENTER, COMBINATION STARTER, MACHINERY DISCONNECT SERIES FRS-R MODEL
$ 53.46
Qty:
add to cart
Part #:BUSS FRS-R-5
CLASS RK5 TYPE 5 INCH UL 248-12, CSA C22.2, CE APPROVAL 600 VOLT AC, 300 VOLT DC VOLTAGE RATING 0.81 INCH DIAMETER 200 KILOAMP SYMMETRICAL (AC), 20 KILOAMP (DC) INTERRUPTING RATING 5 AMP CURRENT RATING FERRULE WITH GROOVED RING TERMINAL TYPE 10 SECOND TIME DELAY AT 500 PERCENT RATED LOAD, DUAL ELEMENT, NON-INDICATING CHARACTERISTICS FUSETRON[TM] BRAND APPLICATION POWER PANELBOARD, MOTOR CONTROL CENTER, COMBINATION STARTER, MACHINERY DISCONNECT FRS-R MODEL
$ 53.46
Qty:
add to cart
Part #:BUSS FRS-R-8
CLASS RK5 TYPE 5 INCH UL 248-12, CSA C22.2, CE APPROVAL 600 VAC/300 VDC VOLTAGE RATING 0.81 INCH DIAMETER 200 KILOAMPERE (SYMMETRICAL), 20 KILOAMPERE (DC) INTERRUPTING RATING 8 AMPERE CURRENT RATING FERRULE WITH GROOVED RING TERMINAL TYPE 10 SEC TIME DELAY (AT 500 PERCENT RATED LOAD), DUAL ELEMENT, NON-INDICATING CHARACTERISTICS FUSETRON[TM] BRAND APPLICATION POWER PANELBOARD, MOTOR CONTROL CENTER, COMBINATION STARTER, MACHINERY DISCONNECT SERIES FRS-R MODEL
$ 53.46
Qty:
add to cart
Part #:BUSS FRS-R-35
CLASS RK5 TYPE 5.5 INCH UL 248-12, CSA C22.2, CE APPROVAL 600 VOLT AC, 250 VOLT DC VOLTAGE RATING 1.06 INCH DIAMETER 200 KILOAMP SYMMETRICAL (AC), 20 KILOAMP (DC) INTERRUPTING RATING 35 AMP CURRENT RATING FERRULE WITH GROOVED RING TERMINAL TYPE 10 SECOND TIME DELAY AT 500 PERCENT RATED LOAD, DUAL ELEMENT, NON-INDICATING CHARACTERISTICS FUSETRON[TM] BRAND APPLICATION POWER PANELBOARD, MOTOR CONTROL CENTER, COMBINATION STARTER, MACHINERY DISCONNECT FRS-R MODEL
$ 81.60
Qty:
add to cart
Part #:BUSS FRS-R-50
CLASS RK5 TYPE 5.5 INCH UL 248-12, CSA C22.2, CE APPROVAL 600 VOLT AC, 250 VOLT DC VOLTAGE RATING 1.06 INCH DIAMETER 200 KILOAMP SYMMETRICAL (AC), 20 KILOAMP (DC) INTERRUPTING RATING 50 AMP CURRENT RATING FERRULE WITH GROOVED RING TERMINAL TYPE 10 SECOND TIME DELAY AT 500 PERCENT RATED LOAD, DUAL ELEMENT, NON-INDICATING CHARACTERISTICS FUSETRON[TM] BRAND APPLICATION POWER PANELBOARD, MOTOR CONTROL CENTER, COMBINATION STARTER, MACHINERY DISCONNECT FRS-R MODEL
$ 81.60
Qty:
add to cart
Part #:BUSS FRS-R-250
CLASS RK5 TYPE 11.63 INCH UL 248-12, CSA C22.2, CE APPROVAL 600 VAC/300 VDC VOLTAGE RATING 2.59 INCH DIAMETER 200 KILOAMPERE (SYMMETRICAL), 20 KILOAMPERE (DC) INTERRUPTING RATING 250 AMPERE CURRENT RATING BLADE TERMINAL TYPE 10 SEC TIME DELAY (AT 500 PERCENT RATED LOAD), DUAL ELEMENT CHARACTERISTICS FUSETRON[TM] BRAND APPLICATION POWER PANELBOARD, MOTOR CONTROL CENTER, COMBINATION STARTER, MACHINERY DISCONNECT SERIES FRS-R MODEL
$ 707.80
Qty:
add to cart
Part #:3M 130C-3/4X30FT
LINERLESS, HIGH VOLTAGE INSULATING TYPE ETHYLENE PROPYLENE RUBBER MATERIAL BLACK FINISH 30 FOOT 0.75 INCH 194 DEG F MAX. CONTINUOUS TEMPERATURE 266 DEG F MAX. SHORT TERM TEMPERATURE 69 KILOVOLT VOLTAGE RATING 30 MIL THICKNESS 750 VOLT PER MIL DIELECTRIC STRENGTH SCOTCH[R] BRAND ROHS COMPLIANT BREAKING STRENGTH 7.5 INCH-POUND APPLICATION PREMIUM GRADE APPLICABLE STANDARD ASTM D-4388 130C MODEL
$ 33.03
Qty:
add to cart
Part #:INT-MAT T104
24 HR TYPE DRAWN STEEL MATERIAL 5 INCH W X 3 INCH D X 7 3/4 INCH H SIZE GRAY FINISH 1 HR MIN. OFF TIME 1 HR MIN. ON TIME CSA (CANADA AND US), CSA C22.2 APPROVAL INDOOR/OUTDOOR LIGHTING, POST LANTERN, SIGN, POOL HEATER, FILTER, HYDROCHLORINATOR, AIR CONDITIONING, BLOWER, ELECTRIC FENCE, PUMP, HEATING/VENTILATING SYSTEM, MUSIC AND SIGNAL SYSTEM, FAN, POULTRY FOGGER, CONVEYER APPLICATION 208 TO 277 VAC AT 60 HZ VOLTAGE RATING NEMA 1 ENCLOSURE 40 AMPERE (RESISTIVE/TUNGSTEN) CURRENT RATING 5 HP AT 240 VAC SINGLE PHASE (28 FLA), 1000 VA (PILOT DUTY) POWER RATING -40 TO 130 DEG F OPERATING TEMPERATURE DPST SWITCH TYPE NO RESERVE POWER INTERMATIC[R] BRAND WITH ON/OFF TRIPPER T100 MODEL
$ 144.46
Qty:
add to cart
Part #:INT-MAT T101R
24 HR TYPE DRAWN STEEL MATERIAL 5 1/2 INCH W X 3 5/8 INCH D X 9 3/8 INCH H SIZE GRAY FINISH 1 HR MIN. OFF TIME 1 HR MIN. ON TIME CSA (CANADA AND US), CSA C22.2 APPROVAL INDOOR/OUTDOOR LIGHTING, POST LANTERN, SIGN, POOL HEATER, FILTER, HYDROCHLORINATOR, AIR CONDITIONING, BLOWER, ELECTRIC FENCE, PUMP, HEATING/VENTILATING SYSTEM, MUSIC AND SIGNAL SYSTEM, FAN, POULTRY FOGGER, CONVEYER APPLICATION 125 VAC AT 60 HZ VOLTAGE RATING NEMA 3R ENCLOSURE 40 AMPERE (RESISTIVE/TUNGSTEN) CURRENT RATING 2 HP AT 120 VAC (24 FLA), 1000 VA (PILOT DUTY) POWER RATING -40 TO 130 DEG F OPERATING TEMPERATURE SPST SWITCH TYPE NO RESERVE POWER INTERMATIC[R] BRAND WITH ON/OFF TRIPPER T100 MODEL
$ 197.28
Qty:
add to cart
Part #:INT-MAT T104R
24 HR TYPE DRAWN STEEL MATERIAL 5 1/2 INCH W X 3 5/8 INCH D X 9 3/8 INCH H SIZE GRAY FINISH 1 HR MIN. OFF TIME 1 HR MIN. ON TIME CSA (CANADA AND US), CSA C22.2 APPROVAL INDOOR/OUTDOOR LIGHTING, POST LANTERN, SIGN, POOL HEATER, FILTER, HYDROCHLORINATOR, AIR CONDITIONING, BLOWER, ELECTRIC FENCE, PUMP, HEATING/VENTILATING SYSTEM, MUSIC AND SIGNAL SYSTEM, FAN, POULTRY FOGGER, CONVEYER APPLICATION 208 TO 277 VAC AT 60 HZ VOLTAGE RATING NEMA 3R ENCLOSURE 40 AMPERE (RESISTIVE/TUNGSTEN) CURRENT RATING 5 HP AT 240 VAC SINGLE PHASE (28 FLA), 1000 VA (PILOT DUTY) POWER RATING -40 TO 130 DEG F OPERATING TEMPERATURE DPST SWITCH TYPE NO RESERVE POWER INTERMATIC[R] BRAND WITH ON/OFF TRIPPER T100 MODEL
$ 191.76
Qty:
add to cart
Part #:BLINE2 4436G
16 GAUGE STEEL MATERIAL ANSI 61 GRAY ACRYLIC ELECTROCOATED OVER WASH AND PHOSPHATE UNDERCOAT FINISH 36 INCH 36 LENGTH IN INCH 4 INCH 4 WIDTH IN INCH 4 INCH 4 HEIGHT IN INCH 3 LENGTH IN FT UL 870, CSA 22.2 APPROVAL NEMA 1, IP30 ENCLOSURE SCREW COVER TYPE (11) 1 INCH BOTTOM, (11) 1 INCH TOP KNOCKOUT(S) B-LINE[R] BRAND APPLICABLE STANDARD IEC 529 HEIGHT IN INCH - UOM IN LENGTH IN FT - UOM FT LENGTH IN INCH - UOM IN WIDTH IN INCH - UOM IN 4436 MODEL
$ 320.48
Qty:
add to cart
Part #:BUSS FRS-R-10
CLASS RK5 TYPE 5 INCH UL 248-12, CSA C22.2, CE APPROVAL 600 VOLT AC, 300 VOLT DC VOLTAGE RATING 0.81 INCH DIAMETER 200 KILOAMP SYMMETRICAL (AC), 20 KILOAMP (DC) INTERRUPTING RATING 10 AMP CURRENT RATING FERRULE WITH GROOVED RING TERMINAL TYPE 10 SECOND TIME DELAY AT 500 PERCENT RATED LOAD, DUAL ELEMENT, NON-INDICATING CHARACTERISTICS FUSETRON[TM] BRAND APPLICATION POWER PANELBOARD, MOTOR CONTROL CENTER, COMBINATION STARTER, MACHINERY DISCONNECT FRS-R MODEL
$ 53.46
Qty:
add to cart
Part #:BUSS FRS-R-100
CLASS RK5 TYPE 7.88 INCH UL 248-12, CSA C22.2, CE APPROVAL 600 VOLT AC, 300 VOLT DC VOLTAGE RATING 1.11 INCH DIAMETER 200 KILOAMP SYMMETRICAL (AC), 20 KILOAMP (DC) INTERRUPTING RATING 100 AMP CURRENT RATING BLADE TERMINAL TYPE 10 SECOND TIME DELAY AT 500 PERCENT RATED LOAD, DUAL ELEMENT, NON-INDICATING CHARACTERISTICS FUSETRON[TM] BRAND APPLICATION POWER PANELBOARD, MOTOR CONTROL CENTER, COMBINATION STARTER, MACHINERY DISCONNECT FRS-R MODEL
$ 149.20
Qty:
add to cart
Part #:BUSS FRS-R-15
CLASS RK5 TYPE 5 INCH UL 248-12, CSA C22.2, CE APPROVAL 600 VOLT AC, 300 VOLT DC VOLTAGE RATING 0.81 INCH DIAMETER 200 KILOAMP SYMMETRICAL (AC), 20 KILOAMP (DC) INTERRUPTING RATING 15 AMP CURRENT RATING FERRULE WITH GROOVED RING TERMINAL TYPE 10 SECOND TIME DELAY AT 500 PERCENT RATED LOAD, DUAL ELEMENT, NON-INDICATING CHARACTERISTICS FUSETRON[TM] BRAND APPLICATION POWER PANELBOARD, MOTOR CONTROL CENTER, COMBINATION STARTER, MACHINERY DISCONNECT FRS-R MODEL
$ 47.38
Qty:
add to cart
Part #:BUSS FRS-R-20
CLASS RK5 TYPE 5 INCH UL 248-12, CSA C22.2, CE APPROVAL 600 VOLT AC, 300 VOLT DC VOLTAGE RATING 0.81 INCH DIAMETER 200 KILOAMP SYMMETRICAL (AC), 20 KILOAMP (DC) INTERRUPTING RATING 20 AMP CURRENT RATING FERRULE WITH GROOVED RING TERMINAL TYPE 10 SECOND TIME DELAY AT 500 PERCENT RATED LOAD, DUAL ELEMENT, NON-INDICATING CHARACTERISTICS FUSETRON[TM] BRAND APPLICATION POWER PANELBOARD, MOTOR CONTROL CENTER, COMBINATION STARTER, MACHINERY DISCONNECT FRS-R MODEL
$ 47.38
Qty:
add to cart
Part #:BUSS FRS-R-25
CLASS RK5 TYPE 5 INCH UL 248-12, CSA C22.2, CE APPROVAL 600 VOLT AC, 300 VOLT DC VOLTAGE RATING 0.81 INCH DIAMETER 200 KILOAMP SYMMETRICAL (AC), 20 KILOAMP (DC) INTERRUPTING RATING 25 AMP CURRENT RATING FERRULE WITH GROOVED RING TERMINAL TYPE 10 SECOND TIME DELAY AT 500 PERCENT RATED LOAD, DUAL ELEMENT, NON-INDICATING CHARACTERISTICS FUSETRON[TM] BRAND APPLICATION POWER PANELBOARD, MOTOR CONTROL CENTER, COMBINATION STARTER, MACHINERY DISCONNECT FRS-R MODEL
$ 47.38
Qty:
add to cart
Part #:BUSS FRS-R-30
CLASS RK5 TYPE 5 INCH UL 248-12, CSA C22.2, CE APPROVAL 600 VOLT AC, 300 VOLT DC VOLTAGE RATING 0.81 INCH DIAMETER 200 KILOAMP SYMMETRICAL (AC), 20 KILOAMP (DC) INTERRUPTING RATING 30 AMP CURRENT RATING FERRULE WITH GROOVED RING TERMINAL TYPE 10 SECOND TIME DELAY AT 500 PERCENT RATED LOAD, DUAL ELEMENT, NON-INDICATING CHARACTERISTICS FUSETRON[TM] BRAND APPLICATION POWER PANELBOARD, MOTOR CONTROL CENTER, COMBINATION STARTER, MACHINERY DISCONNECT FRS-R MODEL
$ 47.38
Qty:
add to cart
Part #:BUSS FRS-R-40
CLASS RK5 TYPE 5.5 INCH UL 248-12, CSA C22.2, CE APPROVAL 600 VOLT AC, 250 VOLT DC VOLTAGE RATING 1.06 INCH DIAMETER 200 KILOAMP SYMMETRICAL (AC), 20 KILOAMP (DC) INTERRUPTING RATING 40 AMP CURRENT RATING FERRULE WITH GROOVED RING TERMINAL TYPE 10 SECOND TIME DELAY AT 500 PERCENT RATED LOAD, DUAL ELEMENT, NON-INDICATING CHARACTERISTICS FUSETRON[TM] BRAND APPLICATION POWER PANELBOARD, MOTOR CONTROL CENTER, COMBINATION STARTER, MACHINERY DISCONNECT FRS-R MODEL
$ 81.60
Qty:
add to cart
Part #:BUSS FRS-R-60
CLASS RK5 TYPE 5.5 INCH UL 248-12, CSA C22.2, CE APPROVAL 600 VOLT AC, 250 VOLT DC VOLTAGE RATING 1.06 INCH DIAMETER 200 KILOAMP SYMMETRICAL (AC), 20 KILOAMP (DC) INTERRUPTING RATING 60 AMP CURRENT RATING FERRULE WITH GROOVED RING TERMINAL TYPE 10 SECOND TIME DELAY AT 500 PERCENT RATED LOAD, DUAL ELEMENT, NON-INDICATING CHARACTERISTICS FUSETRON[TM] BRAND APPLICATION POWER PANELBOARD, MOTOR CONTROL CENTER, COMBINATION STARTER, MACHINERY DISCONNECT FRS-R MODEL
$ 81.60
Qty:
add to cart
Part #:INT-MAT T101
24 HR TYPE DRAWN STEEL MATERIAL 5 INCH W X 3 INCH D X 7 3/4 INCH H SIZE GRAY FINISH 1 HR MIN. OFF TIME 1 HR MIN. ON TIME CSA (CANADA AND US), CSA C22.2 APPROVAL INDOOR/OUTDOOR LIGHTING, POST LANTERN, SIGN, POOL HEATER, FILTER, HYDROCHLORINATOR, AIR CONDITIONING, BLOWER, ELECTRIC FENCE, PUMP, HEATING/VENTILATING SYSTEM, MUSIC AND SIGNAL SYSTEM, FAN, POULTRY FOGGER, CONVEYER APPLICATION 125 VAC AT 60 HZ VOLTAGE RATING NEMA 1 ENCLOSURE 40 AMPERE (RESISTIVE/TUNGSTEN) CURRENT RATING 2 HP AT 120 VAC (24 FLA), 1000 VA (PILOT DUTY) POWER RATING -40 TO 130 DEG F OPERATING TEMPERATURE SPST SWITCH TYPE NO RESERVE POWER INTERMATIC[R] BRAND WITH ON/OFF TRIPPER T100 MODEL
$ 155.26
Qty:
add to cart
 
Displaying: 1 - 21 of 21 Matching Items