42160
32212


Displaying: 1 - 13 of 13 Matching Items
13 Items
View:
Active Filters :
Part #:GE RT1J

THERMAL, BIMETALLIC FIXED HEATER, ADJUSTABLE TRIP TYPE 690 V CONTACT RATING UL (CANADA AND US), CSA C22.2, CE APPROVAL 1-PHASE APPLICATION CONTACTOR/PANEL MOUNTING 3 POLE(S) SCREW TERMINAL TYPE 1NO-1NC AUXILIARY CONTACT 1.8 TO 2.7 AMPERE MOTOR FLA AUTOMATIC/MANUAL RESET TYPE YES HEATER INCLUDED COMPENSATED AMBIENT TEMPERATURE CLASS 10A TRIP CLASS APPLICABLE STANDARD IEC/EN 60947-4-1, IEC/EN 60947-5-1, VDE 0660 USED ON CL00/CL01/CL02/CL25/CL03/CL04/CL45 SERIES CONTACTOR MAXIMUM CIRCUIT BREAKER CURRENT RATING 15 AMPERE RT MODEL
$ 55.00
Part #:GE RT1L

THERMAL, BIMETALLIC FIXED HEATER, ADJUSTABLE TRIP TYPE 690 V CONTACT RATING UL (CANADA AND US), CSA C22.2, CE APPROVAL 1-PHASE APPLICATION CONTACTOR/PANEL MOUNTING 3 POLE(S) SCREW TERMINAL TYPE 1NO-1NC AUXILIARY CONTACT 4 TO 6.3 AMPERE MOTOR FLA AUTOMATIC/MANUAL RESET TYPE YES HEATER INCLUDED COMPENSATED AMBIENT TEMPERATURE CLASS 10A TRIP CLASS APPLICABLE STANDARD IEC/EN 60947-4-1, IEC/EN 60947-5-1, VDE 0660 USED ON CL00/CL01/CL02/CL25/CL03/CL04/CL45 SERIES CONTACTOR MAXIMUM CIRCUIT BREAKER CURRENT RATING 15 AMPERE RT MODEL
$ 55.00
Part #:GE RT1M

THERMAL, BIMETALLIC FIXED HEATER, ADJUSTABLE TRIP TYPE 690 V CONTACT RATING UL (CANADA AND US), CSA C22.2, CE APPROVAL 1 PHASE APPLICATION CONTACTOR MOUNTING 3 POLE(S) SCREW TERMINAL TYPE 1NO-1NC AUXILIARY CONTACT 5.5 TO 8.5 AMPERE MOTOR FLA AUTOMATIC/MANUAL RESET TYPE YES HEATER INCLUDED COMPENSATED AMBIENT TEMPERATURE CLASS 10A TRIP CLASS APPLICABLE STANDARD IEC/EN 60947-4-1, IEC/EN 60947-5-1, VDE 0660 USED ON CL00/CL01/CL02/CL25/CL03/CL04/CL45 SERIES CONTACTOR MAXIMUM CIRCUIT BREAKER CURRENT RATING 15 AMPERE RT MODEL
$ 57.00
Part #:GE RT1P

THERMAL, BIMETALLIC FIXED HEATER, ADJUSTABLE TRIP TYPE 690 V CONTACT RATING UL (CANADA AND US), CSA C22.2, CE APPROVAL 1-PHASE APPLICATION CONTACTOR/PANEL MOUNTING 3 POLE(S) SCREW TERMINAL TYPE 1NO-1NC AUXILIARY CONTACT 10 TO 16 AMPERE MOTOR FLA AUTOMATIC/MANUAL RESET TYPE YES HEATER INCLUDED COMPENSATED AMBIENT TEMPERATURE CLASS 10A TRIP CLASS APPLICABLE STANDARD IEC/EN 60947-4-1, IEC/EN 60947-5-1, VDE 0660 USED ON CL00/CL01/CL02/CL25/CL03/CL04/CL45 SERIES CONTACTOR MAXIMUM CIRCUIT BREAKER CURRENT RATING 35 AMPERE RT MODEL
$ 57.00
Part #:GE THQB2115

MOLDED CASE, FIXED THERMAL MAGNETIC, INTERNAL COMMON TRIP TYPE 2 INCH W X 2-3/8 INCH D X 3-9/32 INCH H SIZE AQ SERIES PANELBOARD USED ON 14 TO 8 AWG (COPPER)/12 TO 8 AWG (ALUMINUM) WIRE SIZE UL APPROVAL 120/240 VAC VOLTAGE RATING 1 INCH BOLT-ON MOUNTING 10 KILOAMPERE INTERRUPTING RATING 15 AMPERE CURRENT RATING 2 POLE(S) COPPER/ALUMINUM LOAD LUG, BOLT-ON TERMINAL TYPE TRIP TYPE NON-INTERCHANGEABLE FRAME TYPE THQB TRIP FUNCTION LI APPLICATION HEATING, AIR CONDITIONING, REFRIGERATION SERIES THQB MODEL
$ 78.00
Part #:GE THQB2150

MOLDED CASE, FIXED THERMAL MAGNETIC, INTERNAL COMMON TRIP TYPE 2 INCH W X 2-3/8 INCH D X 3-9/32 INCH H SIZE AQ SERIES PANELBOARD USED ON 8 TO 3 AWG (COPPER/ALUMINUM) WIRE SIZE UL APPROVAL 120/240 VAC VOLTAGE RATING 1 INCH BOLT-ON MOUNTING 10 KILOAMPERE INTERRUPTING RATING 50 AMPERE CURRENT RATING 2 POLE(S) COPPER/ALUMINUM LOAD LUG, BOLT-ON TERMINAL TYPE TRIP TYPE NON-INTERCHANGEABLE FRAME TYPE THQB TRIP FUNCTION LI APPLICATION HEATING, AIR CONDITIONING, REFRIGERATION SERIES THQB MODEL
$ 78.00
Part #:HUBW BB201W

WITH ANGLE OPENING TYPE IP67/IP54 PIN AND SLEEVE INLET/RECEPTACLE USED ON 3/4 INCH THREADED HUB SIZE UL, CSA APPROVAL ENAMEL PAINTED CAST ALUMINUM BODY MATERIAL 220/380/240/415 VOLT AC 16 AMP 4-POLE 5-WIRE, 347/600 VOLT AC 20 AMP 3-PHASE 4-POLE 5-WIRE, 347/600 VOLT AC 3-PHASE 30 AMP 4-POLE 5-WIRE, 220/380/240/415 VOLT AC 3-PHASE 32 AMP 4-POLE 5-WIRE DEVICE RATING 2 MOUNTING LUG(S) OVERALL DIMENSION 3.75 INCH WIDTH X 4 INCH DEPTH X 5.13 INCH HEIGHT BOX OPENING SIZE 15 DEGREE DEVICE COLOR ALUMINUM
$ 120.24
Part #:HUBW HBL430C7W

POLARIZED TYPE ZYTEL ST801 NYLON MATERIAL 0.375 INCH MIN. CABLE OUTER DIAMETER 1.22 INCH MAX. CABLE OUTER DIAMETER 4 WIRE(S) UL 498/1682/1686C2, CSA C22.2 APPROVAL 480 VOLT AC 3-PHASE VOLTAGE RATING 30 AMP CURRENT RATING 3 POLE(S) IMPACT RESISTANT, WATER TIGHT WIRING DEVICE-KELLEMS BRAND COLOR RED ENCLOSURE RATING IP67 TEMPERATURE RATING -40 TO 75 DEG C APPLICABLE STANDARD IEC 60309-1/60309-2
$ 522.76
Part #:HUBW HBL430P7W

FAN, HEATER, POLARIZED, PUMP, WITH LOCKING RING TYPE ZYTEL ST801 NYLON MATERIAL 0.375 INCH MIN. CABLE OUTER DIAMETER 1.25 INCH MAX. CABLE OUTER DIAMETER 4 WIRE(S) UL 62, UL 94, UL 1682, UL 1686C2, CSA C22.2 APPROVAL 480 VAC 3 PHASE VOLTAGE RATING 30 AMPERE CURRENT RATING 3 POLE(S) IMPACT RESISTANT, MOISTURE RESISTANT, WATER TIGHT HUBBELL[R] BRAND APPLICABLE STANDARD IEC 309-1, 309-2 AREA OF APPLICATION AGRICULTURE, CHEMICAL PROCESSING, CONSTRUCTION, ENTERTAINMENT, FOOD PROCESSING, FOOD SERVICE, MANUFACTURING, MILITARY ENCLOSURE IP67 PIN MATERIAL BRASS OPERATING TEMPERATURE -40 TO 75 DEG C HBL MODEL
$ 494.06
Part #:HUBW HBL460P7W

FAN, HEATER, POLARIZED, PUMP, WITH LOCKING RING TYPE ZYTEL ST801 NYLON MATERIAL 0.7 INCH MIN. CABLE OUTER DIAMETER 1.45 INCH MAX. CABLE OUTER DIAMETER 4 WIRE(S) UL 62, UL 94, UL 1682, UL 1686C2, CSA C22.2 APPROVAL 480 VAC 3 PHASE VOLTAGE RATING 60 AMPERE CURRENT RATING 3 POLE(S) IMPACT RESISTANT, MOISTURE RESISTANT, WATER TIGHT HUBBELL[R] BRAND APPLICABLE STANDARD IEC 309-1, 309-2 AREA OF APPLICATION AGRICULTURE, CHEMICAL PROCESSING, CONSTRUCTION, ENTERTAINMENT, FOOD PROCESSING, FOOD SERVICE, MANUFACTURING, MILITARY ENCLOSURE IP67 PIN MATERIAL BRASS OPERATING TEMPERATURE -40 TO 75 DEG C HBL MODEL
$ 733.90
Part #:GE THQB2120

MOLDED CASE, FIXED THERMAL MAGNETIC, INTERNAL COMMON TRIP TYPE 2 INCH WIDTH X 2-3/8 INCH DEPTH X 3-9/32 INCH HEIGHT SIZE AQ SERIES PANELBOARD USED ON 14 TO 8 AWG (COPPER), 12 TO 8 AWG (ALUMINUM) WIRE SIZE UL APPROVAL 120/240 VOLT AC VOLTAGE RATING 1 INCH BOLT-ON MOUNTING 10 KILOAMP INTERRUPTING RATING 20 AMP CURRENT RATING 2 POLE(S) COPPER/ALUMINUM LOAD LUG TERMINAL TYPE TRIP TYPE NON-INTERCHANGEABLE FRAME TYPE THQB TRIP FUNCTION LI APPLICATION HEATING, AIR CONDITIONING, REFRIGERATION THQB MODEL
$ 78.00
Part #:GE THQB2160

MOLDED CASE, FIXED THERMAL MAGNETIC, INTERNAL COMMON TRIP TYPE 2 INCH WIDTH X 2-3/8 INCH DEPTH X 3-9/32 INCH HEIGHT SIZE AQ SERIES PANELBOARD USED ON 8 TO 3 AWG (COPPER/ALUMINUM) WIRE SIZE UL APPROVAL 120/240 VOLT AC VOLTAGE RATING 1 INCH BOLT-ON MOUNTING 10 KILOAMP INTERRUPTING RATING 60 AMP CURRENT RATING 2 POLE(S) COPPER/ALUMINUM LOAD LUG TERMINAL TYPE TRIP TYPE NON-INTERCHANGEABLE FRAME TYPE THQB TRIP FUNCTION LI APPLICATION HEATING, AIR CONDITIONING, REFRIGERATION THQB MODEL
$ 78.00
Part #:GE RT1K

THERMAL, BIMETALLIC FIXED HEATER, ADJUSTABLE TRIP TYPE 690 V CONTACT RATING UL (CANADA AND US), CSA C22.2, CE APPROVAL 1-PHASE APPLICATION CONTACTOR/PANEL MOUNTING 3 POLE(S) SCREW TERMINAL TYPE 1NO-1NC AUXILIARY CONTACT 2.5 TO 4 AMPERE MOTOR FLA AUTOMATIC/MANUAL RESET TYPE YES HEATER INCLUDED COMPENSATED AMBIENT TEMPERATURE CLASS 10A TRIP CLASS APPLICABLE STANDARD IEC/EN 60947-4-1, IEC/EN 60947-5-1, VDE 0660 USED ON CL00/CL01/CL02/CL25/CL03/CL04/CL45 SERIES CONTACTOR MAXIMUM CIRCUIT BREAKER CURRENT RATING 15 AMPERE RT MODEL
$ 55.00
 
Displaying: 1 - 13 of 13 Matching Items