Contactor Accessories
2 Pole Standard Trip Bolt-on Circuit Breakers


Displaying: 1 - 17 of 17 Matching Items
17 Items
View:
Part #:GE THN3363R

HEAVY DUTY TYPE 9.33 INCH W X 4.86 INCH D X 17.3 INCH H SIZE 3 WIRE(S) UL 98, CSA APPROVAL NEMA 3R ENCLOSURE 100 AMPERE CURRENT RATING 75 HP AT 480 VAC 3-PHASE, 100 HP AT 600 VAC 3-PHASE (NEC STANDARD), 20 HP AT 250 VDC POWER RATING 3 POLE(S) SWITCHING NEUTRAL TYPE 480/600 V AC VOLTAGE RATING 250 V DC VOLTAGE RATING NON-FUSIBLE FUSE PROVISION SPEC-SETTER[TM] BRAND SERIES THN MODEL
$ 830.00
Part #:CARLON E958F

PVC MATERIAL 40 SCHEDULE UL APPROVAL 75 PER CARTON STANDARD PACKAGE 1 INCH TRADE SIZE E958 MODEL
$ 10.72
C
Part #:CARLON E958G

PVC MATERIAL 40 SCHEDULE UL APPROVAL 40 PER CARTON STANDARD PACKAGE 1-1/4 INCH TRADE SIZE E958 MODEL
$ 4.07
C
Part #:CARLON E950FE

BELL TO SPIGOT BUSHING TYPE PVC MATERIAL 3/4 INCH SMALL END TRADE SIZE 1 INCH LARGE END TRADE SIZE UL, CSA APPROVAL 100 STANDARD PACKAGE SCHEDULE 40
$ 14.54
C
Part #:CARLON E950GF

BELL TO SPIGOT BUSHING TYPE PVC MATERIAL 1 INCH SMALL END TRADE SIZE 1-1/4 INCH LARGE END TRADE SIZE UL, CSA APPROVAL 50 STANDARD PACKAGE SCHEDULE 40
$ 18.86
C
Part #:CARLON E958J

PVC MATERIAL 40 SCHEDULE UL APPROVAL 25 PER CARTON STANDARD PACKAGE 2 INCH TRADE SIZE E958 MODEL
$ 22.61
C
Part #:CARLON E950ED

BELL TO SPIGOT BUSHING TYPE PVC MATERIAL 1/2 INCH SMALL END TRADE SIZE 3/4 INCH LARGE END TRADE SIZE UL, CSA APPROVAL 100 STANDARD PACKAGE SCHEDULE 40
$ 6.17
C
Part #:GE BRLL11

ADDER AUXILIARY CONTACT TYPE CL/CK SERIES 5 TO 500 HP CONTACTOR USED ON 1NO-1NC CONTACT CONFIGURATION 600 VAC 10 AMPERE, 600 VDC 2.5 AMPERE CONTACT RATING UL 508, CSA C22.2, CE APPROVAL SCREW TERMINAL TYPE LEFT/RIGHT MOUNTING LOCATION OPERATING TEMPERATURE -25 TO 55 DEG C CL MODEL
$ 19.00
Part #:GE BCLL20

BASE AUXILIARY CONTACT TYPE CL/CK SERIES 5 TO 500 HP CONTACTOR USED ON 2NO CONTACT CONFIGURATION 600 VAC 10 AMPERE, 600 VDC 2.5 AMPERE CONTACT RATING UL 508, CSA C22.2, CE APPROVAL SCREW TERMINAL TYPE LEFT/RIGHT MOUNTING LOCATION OPERATING TEMPERATURE -25 TO 55 DEG C CL MODEL
$ 19.00
Part #:GE BCLL11

BASE AUXILIARY CONTACT TYPE CL/CK SERIES 5 TO 500 HP CONTACTOR USED ON 1NO-1NC CONTACT CONFIGURATION 600 VAC 10 AMPERE, 600 VDC 2.5 AMPERE CONTACT RATING UL 508, CSA C22.2, CE APPROVAL SCREW TERMINAL TYPE LEFT/RIGHT MOUNTING LOCATION OPERATING TEMPERATURE -25 TO 55 DEG C CL MODEL
$ 19.00
Part #:GE THN3361R

HEAVY DUTY TYPE 8.22 INCH W X 4 INCH D X 13.1 INCH H SIZE 3 WIRE(S) UL 98, CSA APPROVAL NEMA 3R ENCLOSURE 30 AMPERE CURRENT RATING 20 HP AT 480 VAC 3-PHASE, 30 HP AT 600 VAC 3-PHASE (NEC STANDARD), 5 HP AT 250/600 VDC POWER RATING 3 POLE(S) SWITCHING NEUTRAL TYPE 480/600 V AC VOLTAGE RATING 250/600 V DC VOLTAGE RATING NON-FUSIBLE FUSE PROVISION SPEC-SETTER[TM] BRAND SERIES THN MODEL
$ 336.00
Part #:GE THN3363

HEAVY DUTY TYPE 9.32 INCH W X 4.81 INCH D X 17.58 INCH H SIZE 3 WIRE(S) UL 98, CSA APPROVAL NEMA 1 ENCLOSURE 100 AMPERE CURRENT RATING 75 HP AT 480 VAC 3-PHASE, 100 HP AT 600 VAC 3-PHASE (NEC STANDARD), 20 HP AT 250 VDC POWER RATING 3 POLE(S) SWITCHING NEUTRAL TYPE 480/600 V AC VOLTAGE RATING 250 V DC VOLTAGE RATING NON-FUSIBLE FUSE PROVISION SPEC-SETTER[TM] BRAND SERIES THN MODEL
$ 536.00
Part #:GE THQB2115

MOLDED CASE, FIXED THERMAL MAGNETIC, INTERNAL COMMON TRIP TYPE 2 INCH W X 2-3/8 INCH D X 3-9/32 INCH H SIZE AQ SERIES PANELBOARD USED ON 14 TO 8 AWG (COPPER)/12 TO 8 AWG (ALUMINUM) WIRE SIZE UL APPROVAL 120/240 VAC VOLTAGE RATING 1 INCH BOLT-ON MOUNTING 10 KILOAMPERE INTERRUPTING RATING 15 AMPERE CURRENT RATING 2 POLE(S) COPPER/ALUMINUM LOAD LUG, BOLT-ON TERMINAL TYPE TRIP TYPE NON-INTERCHANGEABLE FRAME TYPE THQB TRIP FUNCTION LI APPLICATION HEATING, AIR CONDITIONING, REFRIGERATION SERIES THQB MODEL
$ 78.00
Part #:GE THQB2150

MOLDED CASE, FIXED THERMAL MAGNETIC, INTERNAL COMMON TRIP TYPE 2 INCH W X 2-3/8 INCH D X 3-9/32 INCH H SIZE AQ SERIES PANELBOARD USED ON 8 TO 3 AWG (COPPER/ALUMINUM) WIRE SIZE UL APPROVAL 120/240 VAC VOLTAGE RATING 1 INCH BOLT-ON MOUNTING 10 KILOAMPERE INTERRUPTING RATING 50 AMPERE CURRENT RATING 2 POLE(S) COPPER/ALUMINUM LOAD LUG, BOLT-ON TERMINAL TYPE TRIP TYPE NON-INTERCHANGEABLE FRAME TYPE THQB TRIP FUNCTION LI APPLICATION HEATING, AIR CONDITIONING, REFRIGERATION SERIES THQB MODEL
$ 78.00
Part #:GE THN3362

HEAVY DUTY TYPE 9.38 INCH W X 5 INCH D X 17.59 INCH H SIZE 3 WIRE(S) UL 98, CSA APPROVAL NEMA 1 ENCLOSURE 60 AMPERE CURRENT RATING 50 HP AT 480 VAC 3-PHASE, 60 HP AT 600 VAC 3-PHASE (NEC STANDARD), 5 HP AT 125 VDC, 10 HP AT 250 VDC POWER RATING 3 POLE(S) SWITCHING NEUTRAL TYPE 480/600 V AC VOLTAGE RATING 125/250 V DC VOLTAGE RATING NON-FUSIBLE FUSE PROVISION SPEC-SETTER[TM] BRAND SERIES THN MODEL
$ 342.00
Part #:GE THQB2120

MOLDED CASE, FIXED THERMAL MAGNETIC, INTERNAL COMMON TRIP TYPE 2 INCH WIDTH X 2-3/8 INCH DEPTH X 3-9/32 INCH HEIGHT SIZE AQ SERIES PANELBOARD USED ON 14 TO 8 AWG (COPPER), 12 TO 8 AWG (ALUMINUM) WIRE SIZE UL APPROVAL 120/240 VOLT AC VOLTAGE RATING 1 INCH BOLT-ON MOUNTING 10 KILOAMP INTERRUPTING RATING 20 AMP CURRENT RATING 2 POLE(S) COPPER/ALUMINUM LOAD LUG TERMINAL TYPE TRIP TYPE NON-INTERCHANGEABLE FRAME TYPE THQB TRIP FUNCTION LI APPLICATION HEATING, AIR CONDITIONING, REFRIGERATION THQB MODEL
$ 78.00
Part #:GE THQB2160

MOLDED CASE, FIXED THERMAL MAGNETIC, INTERNAL COMMON TRIP TYPE 2 INCH WIDTH X 2-3/8 INCH DEPTH X 3-9/32 INCH HEIGHT SIZE AQ SERIES PANELBOARD USED ON 8 TO 3 AWG (COPPER/ALUMINUM) WIRE SIZE UL APPROVAL 120/240 VOLT AC VOLTAGE RATING 1 INCH BOLT-ON MOUNTING 10 KILOAMP INTERRUPTING RATING 60 AMP CURRENT RATING 2 POLE(S) COPPER/ALUMINUM LOAD LUG TERMINAL TYPE TRIP TYPE NON-INTERCHANGEABLE FRAME TYPE THQB TRIP FUNCTION LI APPLICATION HEATING, AIR CONDITIONING, REFRIGERATION THQB MODEL
$ 78.00
 
Displaying: 1 - 17 of 17 Matching Items