Part #:BUSS LPJ-250SP
- CLASS J TYPE 7.13 INCH UL, CSA C22.2, CE APPROVAL 600 VAC VOLTAGE RATING 2 INCH DIAMETER 300000 AMPERE (SYMMETRICAL) INTERRUPTING RATING 250 AMPERE CURRENT RATING BLADE TERMINAL TYPE 10 SEC TIME DELAY (AT 500 PERCENT RATED LOAD), DUAL ELEMENT CHARACTERISTICS LOW-PEAK. BRAND CURRENT LIMITING LPJ MODEL
$
1,092.52
Qty:
Part #:BUSS LPJ-80SP
- CLASS J TYPE 4.63 INCH UL, CSA C22.2, CE APPROVAL 600 VAC/300 VDC VOLTAGE RATING 1.13 INCH DIAMETER 300 KILOAMPERE (SYMMETRICAL), 100 KILOAMPERE (DC) INTERRUPTING RATING 80 AMPERE CURRENT RATING BLADE TERMINAL TYPE 10 SEC TIME DELAY (AT 500 PERCENT RATED LOAD), DUAL ELEMENT, NON-INDICATING CHARACTERISTICS LOW-PEAK[TM] BRAND ROHS COMPLIANT APPLICATION POWER PANELBOARD, BRANCH CIRCUIT BREAKER PANELBOARD MAIN, MACHINERY DISCONNECT, INDUSTRIAL CONTROL SERIES LPJ MODEL
$
263.58
Qty:
Part #:BUSS LPJ-200SP
- CLASS J TYPE 5.75 INCH UL, CSA C22.2, CE APPROVAL 600 VOLT AC, 300 VOLT DC VOLTAGE RATING 1.5 INCH DIAMETER 300 KILOAMP SYMMETRICAL, 100 KILOAMP (DC) INTERRUPTING RATING 200 AMP CURRENT RATING BLADE TERMINAL TYPE 10 SECOND TIME DELAY AT 500 PERCENT RATED LOAD, DUAL ELEMENT, NON-INDICATING CHARACTERISTICS LOW-PEAK[TM] BRAND ROHS COMPLIANT CONTACT MATERIAL SILVER PLATED APPLICATION POWER PANELBOARD, BRANCH CIRCUIT BREAKER PANELBOARD MAIN, MACHINERY DISCONNECT, INDUSTRIAL CONTROL LPJ MODEL
$
528.66
Qty:
Part #:ARL 143
- 4.46 INCH L X 3.2 INCH H SIZE RIGID CONDUIT/EMT CONDUIT/IMC USED ON UL, CSA APPROVAL 1-1/4 INCH TRADE SIZE 5 HOLE(S) (2) 0.42 INCH, (3) 0.63 INCH HOLE SIZE PACKAGING QUANTITY 25 INSTALLATION CLAMP ON 14 MODEL
$
8.83
Qty:
Part #:ARL 145
- CLAMP-ON TYPE 6.62 INCH LENGTH X 4.55 INCH HEIGHT SIZE RIGID/EMT/IMC CONDUIT USED ON UL, CSA APPROVAL 2 INCH TRADE SIZE 6 HOLE(S) (1) 0.53 INCH, (2) 0.75 INCH, (3) 1 INCH HOLE SIZE
$
17.43
Qty:
Part #:BUSS LPJ-2-1/2SP
- CLASS J TYPE 2.25 INCH UL, CSA C22.2, CE APPROVAL 600 VAC/300 VDC VOLTAGE RATING 0.81 INCH DIAMETER 300 KILOAMPERE (SYMMETRICAL), 100 KILOAMPERE (DC) INTERRUPTING RATING 2-1/2 AMPERE CURRENT RATING FERRULE TERMINAL TYPE 10 SEC TIME DELAY (AT 500 PERCENT RATED LOAD), DUAL ELEMENT, NON-INDICATING CHARACTERISTICS LOW-PEAK[TM] BRAND ROHS COMPLAINT APPLICATION POWER PANELBOARDS, BRANCH CIRCUIT BREAKER PANELBOARD MAINS, MACHINERY DISCONNECTS, INDUSTRIAL CONTROL LPJ MODEL
$
95.08
Qty:
Part #:BUSS LPJ-1SP
- CLASS J TYPE 2.25 INCH UL, CSA C22.2, CE APPROVAL 600 VAC/300 VDC VOLTAGE RATING 0.81 INCH DIAMETER 300 KILOAMPERE (SYMMETRICAL), 100 KILOAMPERE (DC) INTERRUPTING RATING 1 AMPERE CURRENT RATING FERRULE TERMINAL TYPE 10 SEC TIME DELAY (AT 500 PERCENT RATED LOAD), DUAL ELEMENT, NON-INDICATING CHARACTERISTICS LOW-PEAK[TM] BRAND ROHS COMPLIANT APPLICATION POWER PANELBOARD, BRANCH CIRCUIT BREAKER PANELBOARD MAIN, MACHINERY DISCONNECT, INDUSTRIAL CONTROL SERIES LPJ MODEL
$
92.58
Qty:
Part #:BUSS LPJ-30SP
- CLASS J TYPE 2.25 INCH UL, CSA C22.2, CE APPROVAL 600 VAC/300 VDC VOLTAGE RATING 0.81 INCH DIAMETER 300 KILOAMPERE (SYMMETRICAL), 100 KILOAMPERE (DC) INTERRUPTING RATING 30 AMPERE CURRENT RATING FERRULE TERMINAL TYPE 10 SEC TIME DELAY (AT 500 PERCENT RATED LOAD), DUAL ELEMENT, NON-INDICATING CHARACTERISTICS LOW-PEAK[TM] BRAND ROHS COMPLIANT APPLICATION POWER PANELBOARD, BRANCH CIRCUIT BREAKER PANELBOARD MAIN, MACHINERY DISCONNECT, INDUSTRIAL CONTROL SERIES LPJ MODEL
$
97.20
Qty:
Part #:BUSS LPJ-25SP
- CLASS J TYPE 2.25 INCH UL, CSA C22.2, CE APPROVAL 600 VAC/300 VDC VOLTAGE RATING 0.81 INCH DIAMETER 300 KILOAMPERE (SYMMETRICAL), 100 KILOAMPERE (DC) INTERRUPTING RATING 25 AMPERE CURRENT RATING FERRULE TERMINAL TYPE 10 SEC TIME DELAY (AT 500 PERCENT RATED LOAD), DUAL ELEMENT, NON-INDICATING CHARACTERISTICS LOW-PEAK[TM] BRAND ROHS COMPLIANT APPLICATION POWER PANELBOARD, BRANCH CIRCUIT BREAKER PANELBOARD MAIN, MACHINERY DISCONNECT, INDUSTRIAL CONTROL SERIES LPJ MODEL
$
90.56
Qty:
Part #:BUSS LPJ-60SP
- CLASS J TYPE 2.25 INCH UL, CSA C22.2, CE APPROVAL 600 VOLT AC, 300 VOLT DC VOLTAGE RATING 0.81 INCH DIAMETER 300 KILOAMP SYMMETRICAL, 100 KILOAMP (DC) INTERRUPTING RATING 60 AMP CURRENT RATING FERRULE TERMINAL TYPE 10 SECOND TIME DELAY AT 500 PERCENT RATED LOAD, DUAL ELEMENT, NON-INDICATING CHARACTERISTICS LOW-PEAK[TM] BRAND ROHS COMPLIANT CONTACT MATERIAL SILVER PLATED APPLICATION POWER PANELBOARD, BRANCH CIRCUIT BREAKER PANELBOARD MAIN, MACHINERY DISCONNECT, INDUSTRIAL CONTROL LPJ MODEL
$
149.24
Qty:
Part #:TB 371
- BULKHEAD, TAPERED FEMALE THREADED TYPE ELECTRO ZINC PLATED CHROMATE COATED STEEL (BODY), BUNA-N (O-RING), ELECTRO ZINC PLATED CHROMATE COATED HARDENED STEEL (LOCKNUT/SCREW) MATERIAL 1-5/8 INCH DIA SIZE RIGID CONDUIT/IMC USED ON UL 514B, CSA C22.2 APPROVAL 3/4 INCH TRADE SIZE RAINTIGHT, DUSTTIGHT, WATERTIGHT, HAZARDOUS LOCATION NYLON INSULATED THROAT TYPE TEMPERATURE RATING 105 DEG C
Part #:TB 372
- 1 Inch Hub Connector, Steel Electro Zinc Plated, Nylon Insulated for Use with Rigid/IMC Conduit
Rugged steel/malleable iron construction
Tapered internal threads for water-tight/dust-tight union
Threads relieved to prevent bottoming of conduit, ensuring sound assembly
Recessed sealing ring at box end sealing ring captivated
Hardened steel/malleable iron/copper-free aluminum locknuts designed to provide high quality ground continuity extended reach of locknut permits clamping on thin boxes and enclosures
Insulated throat, insulates conductors, prevents abrasion and thinning of conductor insulation, reduces wire pull effort
To positively bond conduit to box or enclosure.
Suitable for hazardous locations use in Class I, Division 2 Class II, Division 1&2 Class III, Division 1 & 2 per NEC 501-4(b) 502-4 (a) and 503-3 (a).
Suitable for hazardous locations use in Class II, Groups E, F, G & Class III locations per CEC 18-202 18-252 18-302 18-352.
When used with neoprene O-ring, provides watertight threaded hub on enclosures
UL Listed 105 degree C
Part #:TB 373
- BULKHEAD, TAPERED FEMALE THREADED TYPE ZINC ELECTROPLATED CHROMATE COATED MALLEABLE IRON HUB, ZINC ELECTROPLATED CHROMATE COATED HARDENED STEEL LOCKNUT/SCREW, NEOPRENE O-RING MATERIAL 2-9/16 INCH DIA SIZE RIGID CONDUIT/IMC USED ON UL 514B, CSA C22.2 APPROVAL LOCKNUT BONDING/GROUNDING SCREW 1-1/8 INCH TRADE SIZE DUSTTIGHT, RAINTIGHT, WATERTIGHT, HAZARDOUS LOCATION NYLON INSULATED THROAT TYPE APPLICABLE STANDARD NFPA 70, JIC EGP1, JIC EMP 1, A-A-50553 ENCLOSURE NEMA FB-1 MAXIMUM WALL THICKNESS 5/16 INCH TEMPERATURE RATING 105 DEG C
Part #:GE TGN3321
- GENERAL DUTY TYPE 6.38 INCH W X 3.31 INCH D X 10.28 INCH H SIZE 3 WIRE(S) UL 98, CSA APPROVAL NEMA 1 ENCLOSURE 30 AMPERE CURRENT RATING 3 HP AT 240 VAC 1-PHASE, 7 HP AT 240 VAC 3-PHASE (NEC STANDARD), 5 HP AT 250/600 VDC POWER RATING 3 POLE(S) SWITCHING NEUTRAL TYPE 240 V AC VOLTAGE RATING 250/600 V DC VOLTAGE RATING NON-FUSIBLE FUSE PROVISION SPEC-SETTER[TM] BRAND SERIES TGN MODEL
$
108.00
Qty:
Part #:GE TG3221
- GENERAL DUTY TYPE 6.38 INCH W X 3.31 INCH D X 10.28 INCH H SIZE 3 WIRE(S) UL 98, CSA APPROVAL NEMA 1 ENCLOSURE 30 AMPERE CURRENT RATING 1 HP AT 240 VAC 1-PHASE, 3 HP AT 240 VAC 3-PHASE (NEC STANDARD), 3 HP AT 240 VAC 1-PHASE, 7 HP AT 240 VAC 3-PHASE (TIME DELAY), 5 HP AT 250/600 VDC POWER RATING 2 POLE(S) CARTRIDGE, CLASS H/K/R FUSE TYPE NO NEUTRAL TYPE 240 V AC VOLTAGE RATING 250/600 V DC VOLTAGE RATING FUSIBLE FUSE PROVISION SPEC-SETTER[TM] BRAND SERIES TG MODEL
$
84.00
Qty:
Part #:GE TG4322R
- GENERAL DUTY TYPE 8.38 INCH W X 3.88 INCH D X 13.68 INCH H SIZE 4 WIRE(S) UL 98, CSA APPROVAL NEMA 3R ENCLOSURE 60 AMPERE CURRENT RATING 3 HP AT 240 VAC 1-PHASE, 7 HP AT 240 VAC 3-PHASE (NEC STANDARD), 10 HP AT 240 VAC 1-PHASE, 15 HP AT 240 VAC 3-PHASE (TIME DELAY), 10 HP AT 250/600 VDC POWER RATING 3 POLE(S) CARTRIDGE, CLASS H/K/R FUSE TYPE NO NEUTRAL TYPE 240 V AC VOLTAGE RATING 250/600 V DC VOLTAGE RATING FUSIBLE FUSE PROVISION SPEC-SETTER[TM] BRAND SERIES TG MODEL
$
305.00
Qty:
Part #:GE TGL1
- GROUND LUG KIT TYPE TC SERIES NON-FUSIBLE DOUBLE-THROW SAFETY SWITCH USED ON (4) 14 TO 8 AWG (COPPER/ALUMINUM), (3) 14 TO 4 AWG (COPPER), (3) 6 TO 4 AWG (ALUMINUM) WIRE SIZE 30 TO 60 AMPERE SWITCH CURRENT RATING 7 TERMINAL(S) 240/600 V SWITCH VOLTAGE RATING SPEC-SETTER[TM] BRAND SERIES TGL MODEL
$
14.00
Qty:
Part #:GE TGN3321R
- GENERAL DUTY TYPE 6.38 INCH W X 3.31 INCH D X 9.78 INCH H SIZE 3 WIRE(S) UL 98, CSA APPROVAL NEMA 3R ENCLOSURE 30 AMPERE CURRENT RATING 3 HP AT 240 VAC 1-PHASE, 7 HP AT 240 VAC 3-PHASE (NEC STANDARD), 5 HP AT 250/600 VDC POWER RATING 3 POLE(S) SWITCHING NEUTRAL TYPE 240 V AC VOLTAGE RATING 250/600 V DC VOLTAGE RATING NON-FUSIBLE FUSE PROVISION SPEC-SETTER[TM] BRAND SERIES TGN MODEL
$
203.00
Qty:
Part #:BUSS LPJ-20SP
- CLASS J TYPE 2.25 INCH UL, CSA C22.2, CE APPROVAL 600 VAC/300 VDC VOLTAGE RATING 0.81 INCH DIAMETER 300 KILOAMPERE (SYMMETRICAL), 100 KILOAMPERE (DC) INTERRUPTING RATING 20 AMPERE CURRENT RATING FERRULE TERMINAL TYPE 10 SEC TIME DELAY (AT 500 PERCENT RATED LOAD), DUAL ELEMENT, NON-INDICATING CHARACTERISTICS LOW-PEAK[TM] BRAND ROHS COMPLIANT APPLICATION POWER PANELBOARD, BRANCH CIRCUIT BREAKER PANELBOARD MAIN, MACHINERY DISCONNECT, INDUSTRIAL CONTROL SERIES LPJ MODEL
$
89.34
Qty:
Part #:BUSS LPJ-35SP
- CLASS J TYPE 2.38 INCH UL, CSA C22.2, CE APPROVAL 600 VAC/300 VDC VOLTAGE RATING 1.06 INCH DIAMETER 300 KILOAMPERE (SYMMETRICAL), 100 KILOAMPERE (DC) INTERRUPTING RATING 35 AMPERE CURRENT RATING FERRULE TERMINAL TYPE 10 SEC TIME DELAY (AT 500 PERCENT RATED LOAD), DUAL ELEMENT, NON-INDICATING CHARACTERISTICS LOW-PEAK[TM] BRAND ROHS COMPLIANT APPLICATION POWER PANELBOARD, BRANCH CIRCUIT BREAKER PANELBOARD MAIN, MACHINERY DISCONNECT, INDUSTRIAL CONTROL SERIES LPJ MODEL
$
151.84
Qty:
Part #:BUSS LPJ-40SP
- CLASS J TYPE 2.38 INCH UL, CSA C22.2, CE APPROVAL 600 VAC/300 VDC VOLTAGE RATING 1.06 INCH DIAMETER 300 KILOAMPERE (SYMMETRICAL), 100 KILOAMPERE (DC) INTERRUPTING RATING 40 AMPERE CURRENT RATING FERRULE TERMINAL TYPE 10 SEC TIME DELAY (AT 500 PERCENT RATED LOAD), DUAL ELEMENT, NON-INDICATING CHARACTERISTICS LOW-PEAK[TM] BRAND ROHS COMPLIANT APPLICATION POWER PANELBOARD, BRANCH CIRCUIT BREAKER PANELBOARD MAIN, MACHINERY DISCONNECT, INDUSTRIAL CONTROL SERIES LPJ MODEL
$
147.78