Part #:BUSS FRS-R-300

CLASS RK5 TYPE 11.63 INCH UL 248-12, CSA C22.2, CE APPROVAL 600 VOLT AC, 300 VOLT DC VOLTAGE RATING 2.34 INCH DIAMETER 200 KILOAMP SYMMETRICAL (AC), 20 KILOAMP (DC) INTERRUPTING RATING 300 AMP CURRENT RATING BLADE TERMINAL TYPE 10 SECOND TIME DELAY AT 500 PERCENT RATED LOAD, DUAL ELEMENT, NON-INDICATING CHARACTERISTICS FUSETRON[TM] BRAND APPLICATION POWER PANELBOARD, MOTOR CONTROL CENTER, COMBINATION STARTER, MACHINERY DISCONNECT FRS-R MODEL
$ 707.80
Part #:BUSS LPJ-200SP

CLASS J TYPE 5.75 INCH UL, CSA C22.2, CE APPROVAL 600 VOLT AC, 300 VOLT DC VOLTAGE RATING 1.5 INCH DIAMETER 300 KILOAMP SYMMETRICAL, 100 KILOAMP (DC) INTERRUPTING RATING 200 AMP CURRENT RATING BLADE TERMINAL TYPE 10 SECOND TIME DELAY AT 500 PERCENT RATED LOAD, DUAL ELEMENT, NON-INDICATING CHARACTERISTICS LOW-PEAK[TM] BRAND ROHS COMPLIANT CONTACT MATERIAL SILVER PLATED APPLICATION POWER PANELBOARD, BRANCH CIRCUIT BREAKER PANELBOARD MAIN, MACHINERY DISCONNECT, INDUSTRIAL CONTROL LPJ MODEL
$ 528.66
Part #:CWD 1254-BOX

SINGLE TYPE GLASS REINFORCED NYLON MATERIAL BROWN COLOR 6-50R CONFIGURATION 3 WIRE(S) UL 498, CSA C22.2 APPROVAL 250 VAC VOLTAGE RATING FLUSH MOUNTING 50 AMPERE CURRENT RATING GROUNDING 2 POLE(S) APPLICATION COMMERCIAL USED WITH COPPER/ALUMINUM WIRE PACKAGING TYPE BOX
$ 24.50
Part #:CWD S42-SP

ANGLED, POLARIZED TYPE THERMOPLASTIC MATERIAL BLACK COLOR 6-30P/6-50P CONFIGURATION 3 WIRE(S) 250 VAC VOLTAGE RATING 30/50 AMPERE CURRENT RATING GROUNDING 2 POLE(S) 1.1 INCH CORD SIZE ROHS/NAFTA COMPLIANT DIMENSION 2.87 INCH W X 1.38 INCH D X 3.37 INCH H APPROVAL UL 498, CSA C22.2, NOM 426
$ 24.79
Part #:BUSS LKN-125

RENEWABLE TYPE 250 VAC VOLTAGE RATING 10000 AMPERE (SYMMETRICAL) INTERRUPTING RATING 125 AMPERE CURRENT RATING CLASS H FUSE TYPE SUPER LAG CHARACTERISTICS LKN MODEL
$ 48.16
Part #:BUSS LP-CC-1-6/10

CLASS CC REJECTION TYPE 1-1/2 INCH UL 248-4, CSA, CE APPROVAL 600 VAC/300 VDC VOLTAGE RATING 13/32 INCH DIAMETER 200000 AMPERE (SYMMETRICAL), 20000 AMPERE (DC) INTERRUPTING RATING 1-6/10 AMPERE CURRENT RATING FERRULE TERMINAL TYPE TIME DELAY CHARACTERISTICS LOW-PEAK. BRAND CURRENT LIMITING MELAMINE TUBE LP-CC MODEL
$ 74.60
Part #:BUSS FRS-R-3

CLASS RK5 TYPE 5 INCH UL 248-12, CSA C22.2, CE APPROVAL 600 VAC/300 VDC VOLTAGE RATING 0.81 INCH DIAMETER 200 KILOAMPERE (SYMMETRICAL), 20 KILOAMPERE (DC) INTERRUPTING RATING 3 AMPERE CURRENT RATING FERRULE WITH GROOVED RING TERMINAL TYPE 10 SEC TIME DELAY (AT 500 PERCENT RATED LOAD), DUAL ELEMENT, NON-INDICATING CHARACTERISTICS FUSETRON[TM] BRAND APPLICATION POWER PANELBOARD, MOTOR CONTROL CENTER, COMBINATION STARTER, MACHINERY DISCONNECT SERIES FRS-R MODEL
$ 53.46
Part #:BUSS FRS-R-5

CLASS RK5 TYPE 5 INCH UL 248-12, CSA C22.2, CE APPROVAL 600 VOLT AC, 300 VOLT DC VOLTAGE RATING 0.81 INCH DIAMETER 200 KILOAMP SYMMETRICAL (AC), 20 KILOAMP (DC) INTERRUPTING RATING 5 AMP CURRENT RATING FERRULE WITH GROOVED RING TERMINAL TYPE 10 SECOND TIME DELAY AT 500 PERCENT RATED LOAD, DUAL ELEMENT, NON-INDICATING CHARACTERISTICS FUSETRON[TM] BRAND APPLICATION POWER PANELBOARD, MOTOR CONTROL CENTER, COMBINATION STARTER, MACHINERY DISCONNECT FRS-R MODEL
$ 53.46
Part #:BUSS FRS-R-8

CLASS RK5 TYPE 5 INCH UL 248-12, CSA C22.2, CE APPROVAL 600 VAC/300 VDC VOLTAGE RATING 0.81 INCH DIAMETER 200 KILOAMPERE (SYMMETRICAL), 20 KILOAMPERE (DC) INTERRUPTING RATING 8 AMPERE CURRENT RATING FERRULE WITH GROOVED RING TERMINAL TYPE 10 SEC TIME DELAY (AT 500 PERCENT RATED LOAD), DUAL ELEMENT, NON-INDICATING CHARACTERISTICS FUSETRON[TM] BRAND APPLICATION POWER PANELBOARD, MOTOR CONTROL CENTER, COMBINATION STARTER, MACHINERY DISCONNECT SERIES FRS-R MODEL
$ 53.46
Part #:BUSS FRS-R-35

CLASS RK5 TYPE 5.5 INCH UL 248-12, CSA C22.2, CE APPROVAL 600 VOLT AC, 250 VOLT DC VOLTAGE RATING 1.06 INCH DIAMETER 200 KILOAMP SYMMETRICAL (AC), 20 KILOAMP (DC) INTERRUPTING RATING 35 AMP CURRENT RATING FERRULE WITH GROOVED RING TERMINAL TYPE 10 SECOND TIME DELAY AT 500 PERCENT RATED LOAD, DUAL ELEMENT, NON-INDICATING CHARACTERISTICS FUSETRON[TM] BRAND APPLICATION POWER PANELBOARD, MOTOR CONTROL CENTER, COMBINATION STARTER, MACHINERY DISCONNECT FRS-R MODEL
$ 81.60
Part #:BUSS FRS-R-50

CLASS RK5 TYPE 5.5 INCH UL 248-12, CSA C22.2, CE APPROVAL 600 VOLT AC, 250 VOLT DC VOLTAGE RATING 1.06 INCH DIAMETER 200 KILOAMP SYMMETRICAL (AC), 20 KILOAMP (DC) INTERRUPTING RATING 50 AMP CURRENT RATING FERRULE WITH GROOVED RING TERMINAL TYPE 10 SECOND TIME DELAY AT 500 PERCENT RATED LOAD, DUAL ELEMENT, NON-INDICATING CHARACTERISTICS FUSETRON[TM] BRAND APPLICATION POWER PANELBOARD, MOTOR CONTROL CENTER, COMBINATION STARTER, MACHINERY DISCONNECT FRS-R MODEL
$ 81.60
Part #:BUSS FRS-R-250

CLASS RK5 TYPE 11.63 INCH UL 248-12, CSA C22.2, CE APPROVAL 600 VAC/300 VDC VOLTAGE RATING 2.59 INCH DIAMETER 200 KILOAMPERE (SYMMETRICAL), 20 KILOAMPERE (DC) INTERRUPTING RATING 250 AMPERE CURRENT RATING BLADE TERMINAL TYPE 10 SEC TIME DELAY (AT 500 PERCENT RATED LOAD), DUAL ELEMENT CHARACTERISTICS FUSETRON[TM] BRAND APPLICATION POWER PANELBOARD, MOTOR CONTROL CENTER, COMBINATION STARTER, MACHINERY DISCONNECT SERIES FRS-R MODEL
$ 707.80
Part #:BUSS LPS-RK-50SP

CLASS RK1 TYPE 5.5 INCH UL 248-12, CSA C22.2, CE APPROVAL 600 VOLT AC, 300 VOLT DC VOLTAGE RATING 1.06 INCH DIAMETER 300 KILOAMP SYMMETRICAL, 100 KILOAMP (DC) INTERRUPTING RATING 50 AMP CURRENT RATING FERRULE WITH GROOVED RING TERMINAL TYPE 10 SECOND TIME DELAY AT 500 PERCENT RATED LOAD, DUAL ELEMENT, NON-INDICATING CHARACTERISTICS LOW-PEAK[TM] BRAND CONTACT MATERIAL SILVER PLATED APPLICATION LARGE DISTRIBUTION SWITCHBOARD, POWER PANELBOARD, MOTOR CONTROL CENTER, MACHINERY DISCONNECT SWITCH LPS-RK MODEL
$ 106.36
Part #:BUSS MDL-2-R

GLASS TUBE TYPE 1 1/4 INCH UL, CSA C22.2, CE APPROVAL 250 VAC VOLTAGE RATING 1/4 INCH DIAMETER 100 AMPERE AT 250 VAC, 10000 AMPERE AT 125 VAC INTERRUPTING RATING 2 AMPERE CURRENT RATING FERRULE TERMINAL TYPE TIME DELAY CHARACTERISTICS BUSSMANN[R] BRAND MDL MODEL
$ 3.32
Part #:BUSS MDA-6

MINIATURE CERAMIC TUBE TYPE 1-1/4 INCH UL 248-14, CSA, CE APPROVAL 250 VAC VOLTAGE RATING 1/4 INCH DIAMETER 200 AMPERE AT 250 VAC, 10000 AMPERE AT 125 VAC INTERRUPTING RATING 6 AMPERE CURRENT RATING FERRULE TERMINAL TYPE TIME DELAY CHARACTERISTICS MDA MODEL
$ 6.22
Part #:GE THQL1115

MOLDED CASE, FIXED THERMAL MAGNETIC TYPE 1 INCH WIDTH X 2-3/8 INCH DEPTH X 3-9/32 INCH HEIGHT SIZE AL SERIES PANELBOARD USED ON 14 TO 8 AWG (COPPER), 12 TO 8 AWG (ALUMINUM) WIRE SIZE UL APPROVAL 120/240 VOLT AC VOLTAGE RATING 1 INCH PLUG-IN MOUNTING 10 KILOAMP INTERRUPTING RATING 15 AMP CURRENT RATING 1 POLE(S) COPPER/ALUMINUM LOAD LUG TERMINAL TYPE TRIP TYPE NON-INTERCHANGEABLE FRAME TYPE THQL TRIP FUNCTION LI APPLICATION HEATING, AIR CONDITIONING, REFRIGERATION THQL MODEL
$ 21.00
Part #:GE THQL2120

MOLDED CASE, FIXED THERMAL MAGNETIC, INTERNAL COMMON TRIP TYPE 2 INCH WIDTH X 2-3/8 INCH DEPTH X 3-9/32 INCH HEIGHT SIZE AL SERIES PANELBOARD USED ON 14 TO 8 AWG (COPPER), 12 TO 8 AWG (ALUMINUM) WIRE SIZE UL APPROVAL 120/240 VOLT AC VOLTAGE RATING 1 INCH PLUG-IN MOUNTING 10 KILOAMP INTERRUPTING RATING 20 AMP CURRENT RATING 2 POLE(S) COPPER/ALUMINUM LOAD LUG TERMINAL TYPE TRIP TYPE NON-INTERCHANGEABLE FRAME TYPE THQL TRIP FUNCTION LI APPLICATION HEATING, AIR CONDITIONING, REFRIGERATION THQL MODEL
$ 48.00
Part #:GE THQL2140

MOLDED CASE, FIXED THERMAL MAGNETIC, INTERNAL COMMON TRIP TYPE 2 INCH WIDTH X 2-3/8 INCH DEPTH X 3-9/32 INCH HEIGHT SIZE AL SERIES PANELBOARD USED ON 8 TO 3 AWG (COPPER/ALUMINUM) WIRE SIZE UL APPROVAL 120/240 VOLT AC VOLTAGE RATING 1 INCH PLUG-IN MOUNTING 10 KILOAMP INTERRUPTING RATING 40 AMP CURRENT RATING 2 POLE(S) COPPER/ALUMINUM LOAD LUG TERMINAL TYPE TRIP TYPE NON-INTERCHANGEABLE FRAME TYPE THQL TRIP FUNCTION LI APPLICATION HEATING, AIR CONDITIONING, REFRIGERATION THQL MODEL
$ 53.00
Part #:GE THQP115

MOLDED CASE, FIXED THERMAL MAGNETIC TYPE 1/2 INCH WIDTH X 2-3/8 INCH DEPTH X 3-9/32 INCH HEIGHT SIZE 14 TO 8 AWG (COPPER), 12 TO 8 AWG (ALUMINUM) WIRE SIZE UL APPROVAL 120/240 VOLT AC VOLTAGE RATING 1/2 INCH PLUG-IN MOUNTING 10 KILOAMP INTERRUPTING RATING 15 AMP CURRENT RATING 1 POLE(S) COPPER/ALUMINUM LOAD LUG TERMINAL TYPE TRIP TYPE NON-INTERCHANGEABLE FRAME TYPE THQP TRIP FUNCTION LI APPLICATION HEATING, AIR CONDITIONING, REFRIGERATION THQP MODEL
$ 21.00
Part #:HUBW HBL2711

POLARIZED TYPE NYLON MATERIAL BLACK, WHITE COLOR L14-30P CONFIGURATION 4 WIRE(S) UL 498, UL FS WC-596-G, CSA C22.2M APPROVAL 125/250 V VOLTAGE RATING 30 AMPERE CURRENT RATING GROUNDING 3 POLE(S) CHEMICAL RESISTANT, DUST TIGHT 0.35 TO 1.15 INCH CORD SIZE INSULGRIP[R] BRAND BLADE MATERIAL BRASS ENCLOSURE IP20 OPERATING TEMPERATURE -40 TO 60 DEG C
$ 77.70
Part #:HUBW HBL2715M3

POLARIZED TYPE NYLON CASING MATERIAL L14-30P CONFIGURATION UL FS, CSA APPROVAL 125/250 V VOLTAGE RATING 30 AMPERE CURRENT RATING GROUNDING 3 POLE(S) INSULGRIP[R] BRAND
$ 125.76
Part #:HUBW HBL2710

SINGLE LOCKING TYPE NYLON FACE MATERIAL BLACK COLOR L14-30R CONFIGURATION 4 WIRE(S) UL 498, UL FS WC-596-G, CSA C22.2M APPROVAL 125/250 V VOLTAGE RATING FLUSH MOUNTING 30 AMPERE CURRENT RATING GROUNDING 3 POLE(S) BACK, SIDE WIRING 1.56 INCH FACE OUTER DIAMETER TWIST-LOCK[R] BRAND CONTACT MATERIAL BRASS OPERATING TEMPERATURE -40 TO 60 DEG C RATING 125/250 V 30 AMPERE
$ 106.08
Part #:HUBW L1420P

POLARIZED TYPE UL, CSA APPROVAL 125/250 V VOLTAGE RATING 20 AMPERE CURRENT RATING GROUNDING 2 POLE(S) SELECT SPEC[T] BRAND
$ 60.58
Part #:SIEM5 Q230

MINIATURE, THERMAL AND FIXED MAGNETIC TRIP, COMMON TRIP TYPE 2 INCH WIDTH X 3 INCH DEPTH X 3-1/8 INCH HEIGHT SIZE LOAD CENTER USED ON 14 TO 6 AWG (COPPER/ALUMINUM) WIRE SIZE UL 489 APPROVAL 120/240 VOLT AC VOLTAGE RATING PLUG-IN MOUNTING 10 KILOAMP INTERRUPTING RATING 30 AMP AT 40 DEG C CURRENT RATING 2 POLE(S) LOAD LUG TERMINAL TYPE SPEEDFAX[TM], INSTA-WIRE BRAND FRAME TYPE QP QP MODEL
$ 161.14
 
Displaying: 1 - 24 of 66 Matching Items