Part #:WIRE UF-B-8/3-CU-WG-500S/R
- UF-B TYPE 500 FT 1059 MIL X 319 MIL OUTER DIAMETER ANNEALED SOFT COPPER CONDUCTOR MATERIAL UL 83/493 APPROVAL 600 V VOLTAGE RATING 40 AMPERE CURRENT RATING 90 DEG C TEMPERATURE RATING 344 LB/MFT WEIGHT 3 CONDUCTOR(S) PVC INSULATION MATERIAL WITH GROUND WIRE 8 AWG CONDUCTOR SIZE NYLON JACKET MATERIAL SPOOL/REEL PACKAGE TYPE 7 STRANDS STRANDING 10 AWG GROUND CONDUCTOR SIZE
$
38.88
FT
Qty:
Part #:THHN 350BK500
- APPLICATIONS
Southwire Type THHN or THWN-2 conductors are primarily used in conduit and cable trays for services, feeders, and branch circuits in commercial or industrial applications as specified in the 2008 National Electrical Code. When used as Type THHN, or T90 Nylon conductor is suitable for use in dry locations at temperatures not to exceed 90 °C. When used as Type THWN-2 or TWN75, conductor is suitable for use in wet or dry locations at temperatures not to exceed 90 °C or not to exceed 75 °C when exposed to oil or coolant. When used as Type MTW, conductor is suitable for use in wet locations or when exposed to oil or coolant at temperatures not to exceed 60 °C or dry locations at temperatures not to exceed 90 °C (with ampacity limited to that for 75 °C conductor temperature per NFPA 79). Conductor temperatures not to exceed 105 °C in dry locations when rated AWM and used as appliance wiring material or when used asT90 Nylon. Voltage for all applications is 600 volts.
$
12.42
M
Qty:
Part #:SAB 39550340
-
Type
European Standardized Cables
Segment
<HAR> Rubber Cordage
Series
H07RN-F
Gauge (AWG)
12
Conductor Count
3
Voltage
750
Insulation
Rubber
Jacket Material
Rubber
Jacket Color
Black
Approvals
RoHS, CE, <HAR>
$
8.70
Qty:
Part #:CAT 5E4PR
- Blue category 5e non-plenum cable, 1000 feet.
All pair counts meet Cat 5e Power Sum backbone transmission requirements
Suitable for high-speed data transmission
Third-party verified for guaranteed performance
24 AWG solid bare annealed copper
ANSI/TIA/EIA 568 B.2,ICEA S-90-661, UL & C(UL) Type CMR (UL 1666) for Non-Plenum, UL 444, RoHS Compliant
$
0.24
M
Qty:
Part #:THHN 4GN500
- APPLICATIONS
Southwire Type THHN or THWN-2 conductors are primarily used in conduit and cable trays for services, feeders, and branch circuits in commercial or industrial applications as specified in the 2008 National Electrical Code. When used as Type THHN, or T90 Nylon conductor is suitable for use in dry locations at temperatures not to exceed 90 °C. When used as Type THWN-2 or TWN75, conductor is suitable for use in wet or dry locations at temperatures not to exceed 90 °C or not to exceed 75 °C when exposed to oil or coolant. When used as Type MTW, conductor is suitable for use in wet locations or when exposed to oil or coolant at temperatures not to exceed 60 °C or dry locations at temperatures not to exceed 90 °C (with ampacity limited to that for 75 °C conductor temperature per NFPA 79). Conductor temperatures not to exceed 105 °C in dry locations when rated AWM and used as appliance wiring material or when used asT90 Nylon. Voltage for all applications is 600 volts.
$
2.58
M
Qty:
Part #:THHN 4OBK500
- APPLICATIONS
Southwire Type THHN or THWN-2 conductors are primarily used in conduit and cable trays for services, feeders, and branch circuits in commercial or industrial applications as specified in the 2008 National Electrical Code. When used as Type THHN, or T90 Nylon conductor is suitable for use in dry locations at temperatures not to exceed 90 °C. When used as Type THWN-2 or TWN75, conductor is suitable for use in wet or dry locations at temperatures not to exceed 90 °C or not to exceed 75 °C when exposed to oil or coolant. When used as Type MTW, conductor is suitable for use in wet locations or when exposed to oil or coolant at temperatures not to exceed 60 °C or dry locations at temperatures not to exceed 90 °C (with ampacity limited to that for 75 °C conductor temperature per NFPA 79). Conductor temperatures not to exceed 105 °C in dry locations when rated AWM and used as appliance wiring material or when used asT90 Nylon. Voltage for all applications is 600 volts.
$
7.78
FT
Qty:
Part #:USE 40BKSTAL1000R
- USE/RHH/RHW Underground service entrance cable in black color, has 18-Strand aluminum conductor of size 4/0 AWG. It features 80-mil cross-linked polyethylene insulation that offers resistance against moisture, heat and sunlight. Cable has voltage rating of 600 Volts and current rating of 205 Amps. It has outer diameter of 635 mil. Cable withstands temperature rating of 90 deg C in dry conditions. Cable is UL listed, RoHS/REACH compliant, NEMA rated and meets ASTM standards.
$
1.09
M
Qty:
Part #:SEU 404020AL500R
- Aluminum SEU cable is primarily used as panel feeder in multiple unit dwellings and for branch circuits. Maximum operating temperature is not to exceed 90°C in wet locations. Voltage rating is 600 volts.
ConstructionConductor - Aluminum SEU cable has a compact strand soft drawn 8000 series aluminum conductor, per ASTM B-801
Insulation - Aluminum SEU cable has a type XHHW-2 cross linked polyethylene (XLP) insulation. The conductors are cabled together with an aluminum alloy concentric neutral and covered with a reinforced binder tape.
Jacket - Aluminum SEU cable has a gray sunlight resistance polyvinyl chloride (PVC) jacket.
StandardsUL 44, 854Federal Specification J-C - 30BAmpacities based on National Electric Code, 2005 edition, section 310-1560°C when terminated to equipment for circuits rated 100amps or less or marked for 14ga through 1ga conductors70°C when terminated to equipment for circuits rated over 100amps or marked for conductors larger than 1ga90°C wet or dry locations For dwelling units, conductors shall be permitted at listed Ampacities to be utilized as 120/240 volt, 3-wire, single phase service conductors that supply the total load
Specifications
Insulated Conductor Size4/0Bare Neutral Size2/0Outside Diameter0.818 inchesAmpacity205 amps @90°CNet Weight1.003 lbs/ft
$
4.00
M
Qty:
Part #:NMB 63WG500R
- 6-3 W/G NM-B Wire Black
Non-metallic sheathed NM-B cable is used in normally dry installations in residential wiring, as branch circuits for outlets, lighting and other residential loads. Its applications are outlined in NEC 2008 and NEC 2011 Article 334. NM-B is rated at 600 volts and although it is rated at a conductor temperature of 90°C dry , its ampacity is limited to 60°C according to the NEC 2008 and NEC 2011. It may be fished through masonry or tile walls, where not exposed or subject to excessive moisture or dampness. NM-B cables are LEAD FREE and RoHS compliant. Equivalent to Romex NM-B.
StandardsMeets or exceeds all applicable ASTM specificationsUL 83 Thermoplastic Insulated Wires and CablesUL 719 Non-Metallic CablesFederal Specification A-A-59544 and requirements of the NEC.Voltage rating - 600 volts.
ConstructionConductorsSolid 14 to 10 AWG annealed soft bare copper per ASTM B3.Stranded 8 AWG and larger annealed soft bare copper per ASTM B3 and B8.InsulationColor coded polyvinyl chloride (PVC) compound with a nylon covering meeting the required thickness of Type THHN. Conductor insulation is rated 90°C.GroundSoft, bare copper solid per ASTM B3 and stranded per ASTM B3 and B8Sheath30 mil color coded PVC sheath rated 90C is applied over the completed assembly
Specifications
Size6 AWGNumber of Conductors3PVC Insulation Thickness0.76 mm / 0.029 inchesGround Wire Size10 AWGNylon Thickness0.13 mm / 0.005 inchesNominal Cable Dimensions16.0 mm / 0.62 inchesWeight per foot0.357 lbsAllowable Ampacity55 Amps
$
4.94
M
Qty:
Part #:THHN 6WE500
- Southwire Type THHN or THWN-2 conductors are primarily used in conduit and cable trays for services, feeders, and branch circuits in commercial or industrial applications as specified in the 2008 National Electrical Code. When used as Type THHN, or T90 Nylon conductor is suitable for use in dry locations at temperatures not to exceed 90 °C. When used as Type THWN-2 or TWN75, conductor is suitable for use in wet or dry locations at temperatures not to exceed 90 °C or not to exceed 75 °C when exposed to oil or coolant. When used as Type MTW, conductor is suitable for use in wet locations or when exposed to oil or coolant at temperatures not to exceed 60 °C or dry locations at temperatures not to exceed 90 °C (with ampacity limited to that for 75 °C conductor temperature per NFPA 79). Conductor temperatures not to exceed 105 °C in dry locations when rated AWM and used as appliance wiring material or when used asT90 Nylon. Voltage for all applications is 600 volts.
$
1.22
M
Qty:
Part #:THHN 8GN500
- Southwire Type THHN or THWN-2 conductors are primarily used in conduit and cable trays for services, feeders, and branch circuits in commercial or industrial applications as specified in the 2008 National Electrical Code. When used as Type THHN, or T90 Nylon conductor is suitable for use in dry locations at temperatures not to exceed 90 °C. When used as Type THWN-2 or TWN75, conductor is suitable for use in wet or dry locations at temperatures not to exceed 90 °C or not to exceed 75 °C when exposed to oil or coolant. When used as Type MTW, conductor is suitable for use in wet locations or when exposed to oil or coolant at temperatures not to exceed 60 °C or dry locations at temperatures not to exceed 90 °C (with ampacity limited to that for 75 °C conductor temperature per NFPA 79). Conductor temperatures not to exceed 105 °C in dry locations when rated AWM and used as appliance wiring material or when used asT90 Nylon. Voltage for all applications is 600 volts.
$
0.86
M
Qty:
Part #:SOU C588
-
Exceptionally strong design with high-carbon steel core and tip
Tough copper coating won't crack or tear
Continuous electro-plating process ensures permanent bond
$
25.08
Qty:
Part #:OMN AF61802
- Conductor &bull 7 strand soft drawn tinned copper, Class B per ASTM B8 and B33 Insulation &bull Flame-retardant Ethylene-Propylene-rubber Individual Shield &bull Aluminum/Mylar shielding tape Drain Wire &bull Tinned copper applied helically over core and twisted pairs Overall Shield &bull Aluminum/Mylar shielding tape Jacket &bull Chlorinated Polyethylene (CPE) Ripcord &bull Nylon
Applications &bull Process instrumentation applications where resistance to moisture, chemicals, thermal stability, and physical durability are essential. &bull Use in high performance applications where reliability is essential Standards &bull Rated 90°C wet or dry &bull UL Type TC &bull ICEA S-82-552 - 600 Volts &bull IEEE 1202 (70,000 BTU/hr)/ CSA FT4 &bull ICEA T-29-520-(210,000 BTU/hr) &bull UL Subject 1277 (70,000 BTU/hr) &bull OSHA Acceptable
$
2.61
M
Qty:
Part #:MC CABLE63WGREENGRN
- 6-3C Metal Clad (MC) Cable with Ground, Aluminum Armored, Stranded Copper Conductors
Metal Clad Cable may be used for branch, feeder and service for distribution in commercial, industrial, and multi-residential construction. They are suitable for installation in motion picture studios, theaters, and places of assembly (100 people or more) per NEC Articles 230.43, 300.22(C), 330, 396, 518, 520, 530 and 645. These cables may be installed in approved raceways and as open runs of cable on a messenger. They may be installed exposed, concealed or in cable tray and may be run in spaces used for environmental air in accordance with NEC Article 300.22(C) ONLY.
- Meets UL 83 Thermoplastic Insulated Wires and Cables- Tested to UL 1479 Fire Tests of Through-Penetration Firestops for one, two or three hour fire rated assemblies (for cables up to #2 AWG)- Meets UL 1569 Metal Clad Cables- Meets UL 1581 Reference Standard for Electrical Wires, Cables, and Flexible Cords- Meets UL 2256 Wire and Cable Test Methods- Designated Type MC per NEC Article 330
Specifications
Size6 AWGOutside Diameter0.840 inches
Ampere Rating THHN75
$
5.93
M
Qty:
Part #:HOR HE800DIQ712
- 14 DC Inputs (12/24VDC), 10 Relay Outputs (250vac, 30VDC, 3.0A)
$
1,618.00
Qty:
Part #:CRL 76502.18.06
- MTW/TFF/AWM (UL), TEW (CSA) TYPE 2000 FT 2000 LENGTH IN FT 0.11 INCH OUTER DIAMETER ASTM B-8 ANNEALED BARE COPPER CONDUCTOR MATERIAL UL, CSA APPROVAL 600 V VOLTAGE RATING -40 TO 90 DEG C (MTW/TFF), -20 TO 105 DEG C (AWM/TEW) TEMPERATURE RATING 10 LB/MFT WEIGHT PVC INSULATION MATERIAL 18 AWG CONDUCTOR SIZE GREEN COLOR CODE 16/30 STRANDS STRANDING CAROL[R] BRAND LENGTH IN FT - UOM FT
$
0.13
M
Qty:
Part #:CRL 76502.18.07
- MTW/TFF/AWM (UL), TEW (CSA) TYPE 2000 FT 2000 LENGTH IN FT 0.11 INCH OUTER DIAMETER ASTM B-8 ANNEALED BARE COPPER CONDUCTOR MATERIAL UL, CSA APPROVAL 600 V VOLTAGE RATING -40 TO 90 DEG C (MTW/TFF), -20 TO 105 DEG C (AWM/TEW) TEMPERATURE RATING 10 LB/MFT WEIGHT PVC INSULATION MATERIAL 18 AWG CONDUCTOR SIZE BLUE COLOR CODE 16/30 STRANDS STRANDING CAROL[R] BRAND LENGTH IN FT - UOM FT
$
0.13
M
Qty:
Part #:MTW 18RD2500
- 18 AWG MTW/UL1015 Hook-Up Stranded Wire, 600V.
18 AWG UL1015Type conductors are primarily used in control cabinets, in machine tool applications and appliance wiring applications. Applications requiring Type MTW conductor is appropriate for use in dry locations at 90°C, or not to exceed 60°C in wet locations or where exposed to oils or coolants. Applications requiring Type AWM conductor is appropriate for use at temperatures to not exceed 105°C in dry locations.ConductorBare Copper
InsulationPolyvinyl Chloride (PVC)StandardsUL recognized AWM Style 1015 per 758. Passes VW-1 vertical flame test. CSA TEW or AWM
Specifications
Size18 AWGNumber of Strands16Temp105°CInsulation Thickness0.031 inchesOutside Diameter0.11 inchesWeight0.010 lbs per ftVoltage600V
$
0.16
M
Qty:
Part #:MTW 18BE2500
- 18 AWG MTW/UL1015 Hook-Up Stranded Wire, 600V.
18 AWG UL1015Type conductors are primarily used in control cabinets, in machine tool applications and appliance wiring applications. Applications requiring Type MTW conductor is appropriate for use in dry locations at 90°C, or not to exceed 60°C in wet locations or where exposed to oils or coolants. Applications requiring Type AWM conductor is appropriate for use at temperatures to not exceed 105°C in dry locations.ConductorBare Copper
InsulationPolyvinyl Chloride (PVC)StandardsUL recognized AWM Style 1015 per 758. Passes VW-1 vertical flame test. CSA TEW or AWM
Specifications
Size18 AWGNumber of Strands16Temp105°CInsulation Thickness0.031 inchesOutside Diameter0.11 inchesWeight0.010 lbs per ftVoltage600V
$
0.14
FT
Qty:
Part #:CRL 76512.18.02
- MTW/TFF/AWM (UL), TEW (CSA) TYPE 2000 FT 2000 LENGTH IN FT 0.123 INCH OUTER DIAMETER ASTM B-8 ANNEALED BARE COPPER CONDUCTOR MATERIAL UL, CSA APPROVAL 600 V VOLTAGE RATING -40 TO 90 DEG C (MTW/TFF), -20 TO 105 DEG C (AWM/TEW) TEMPERATURE RATING 14 LB/MFT WEIGHT PVC INSULATION MATERIAL 16 AWG CONDUCTOR SIZE WHITE COLOR CODE 26/30 STRANDS STRANDING CAROL[R] BRAND LENGTH IN FT - UOM FT
$
0.22
M
Qty:
Part #:CRL 76512.18.03
- MTW/TFF/AWM (UL), TEW (CSA) TYPE 2000 FT 2000 LENGTH IN FT 0.123 INCH OUTER DIAMETER ASTM B-8 ANNEALED BARE COPPER CONDUCTOR MATERIAL UL, CSA APPROVAL 600 V VOLTAGE RATING -40 TO 90 DEG C (MTW/TFF), -20 TO 105 DEG C (AWM/TEW) TEMPERATURE RATING 14 LB/MFT WEIGHT PVC INSULATION MATERIAL 16 AWG CONDUCTOR SIZE RED COLOR CODE 26/30 STRANDS STRANDING CAROL[R] BRAND LENGTH IN FT - UOM FT
$
0.16
M