Part #:THHN 500BK500
- APPLICATIONS
Southwire Type THHN or THWN-2 conductors are primarily used in conduit and cable trays for services, feeders, and branch circuits in commercial or industrial applications as specified in the 2008 National Electrical Code. When used as Type THHN, or T90 Nylon conductor is suitable for use in dry locations at temperatures not to exceed 90 °C. When used as Type THWN-2 or TWN75, conductor is suitable for use in wet or dry locations at temperatures not to exceed 90 °C or not to exceed 75 °C when exposed to oil or coolant. When used as Type MTW, conductor is suitable for use in wet locations or when exposed to oil or coolant at temperatures not to exceed 60 °C or dry locations at temperatures not to exceed 90 °C (with ampacity limited to that for 75 °C conductor temperature per NFPA 79). Conductor temperatures not to exceed 105 °C in dry locations when rated AWM and used as appliance wiring material or when used asT90 Nylon. Voltage for all applications is 600 volts.
$
17.76
M
Qty:
Part #:SEU 224AL500R
- Aluminum SEU cable is primarily used as panel feeder in multiple unit dwellings and for branch circuits. Maximum operating temperature is not to exceed 90°C in wet locations. Voltage rating is 600 volts.
ConstructionConductor - Aluminum SEU cable has a compact strand soft drawn 8000 series aluminum conductor, per ASTM B-801
Insulation - Aluminum SEU cable has a type XHHW-2 cross linked polyethylene (XLP) insulation. The conductors are cabled together with an aluminum alloy concentric neutral and covered with a reinforced binder tape.
Jacket - Aluminum SEU cable has a gray sunlight resistance polyvinyl chloride (PVC) jacket.
StandardsUL 44, 854Federal Specification J-C - 30BAmpacities based on National Electric Code, 2005 edition, section 310-1560°C when terminated to equipment for circuits rated 100amps or less or marked for 14ga through 1ga conductors70°C when terminated to equipment for circuits rated over 100amps or marked for conductors larger than 1ga90°C wet or dry locations For dwelling units, conductors shall be permitted at listed Ampacities to be utilized as 120/240 volt, 3-wire, single phase service conductors that supply the total load
Specifications
Insulated Conductor Size2 AWGBare Neutral Size2 AWGOutside Diameter0.566inchesAmpacity100 amps @90°CNet Weight.259 lbs/ft
$
1.74
M
Qty:
Part #:SOU 22955901
- THHN, THWN, MTW, AWM TYPE 500 FT 500 LENGTH IN FT 109 MIL OUTER DIAMETER ANNEALED COPPER CONDUCTOR MATERIAL UL 83, UL 1063, UL 1581, UL (CANADA AND US), CSA APPROVAL 600 V VOLTAGE RATING 15 AMPERE CURRENT RATING 90 DEG C TEMPERATURE RATING 16 LB/MFT WEIGHT PVC INSULATION MATERIAL 14 AWG CONDUCTOR SIZE NYLON JACKET MATERIAL SPOOL PACKAGE TYPE 19 STRANDS STRANDING BLACK INSULATION COLOR NOLUBE[T], SIM TECHNOLOGY[R] BRAND
$
0.26
M
Qty:
Part #:SOU 22956701
- THHN, THWN, MTW, AWM TYPE 500 FT 500 LENGTH IN FT 109 MIL OUTER DIAMETER ANNEALED COPPER CONDUCTOR MATERIAL UL 83, UL 1063, UL 1581, UL (CANADA AND US), CSA APPROVAL 600 V VOLTAGE RATING 15 AMPERE CURRENT RATING 90 DEG C TEMPERATURE RATING 16 LB/MFT WEIGHT PVC INSULATION MATERIAL 14 AWG CONDUCTOR SIZE NYLON JACKET MATERIAL SPOOL PACKAGE TYPE 19 STRANDS STRANDING WHITE INSULATION COLOR NOLUBE[T], SIM TECHNOLOGY[R] BRAND
$
0.17
M
Qty:
Part #:SOU 22957501
- THHN, THWN, MTW, AWM TYPE 500 FT 500 LENGTH IN FT 109 MIL OUTER DIAMETER ANNEALED COPPER CONDUCTOR MATERIAL UL 83, UL 1063, UL 1581, UL (CANADA AND US), CSA APPROVAL 600 V VOLTAGE RATING 15 AMPERE CURRENT RATING 90 DEG C TEMPERATURE RATING 16 LB/MFT WEIGHT PVC INSULATION MATERIAL 14 AWG CONDUCTOR SIZE NYLON JACKET MATERIAL SPOOL PACKAGE TYPE 19 STRANDS STRANDING RED INSULATION COLOR NOLUBE[T], SIM TECHNOLOGY[R] BRAND
$
0.19
M
Qty:
Part #:SOU 22965801
- THHN, THWN, MTW, AWM TYPE 500 FT 500 LENGTH IN FT 128 MIL OUTER DIAMETER ANNEALED COPPER CONDUCTOR MATERIAL UL 83, UL 1063, UL 1581, UL (CANADA AND US), CSA APPROVAL 600 V VOLTAGE RATING 20 AMPERE CURRENT RATING 90 DEG C TEMPERATURE RATING 24 LB/MFT WEIGHT PVC INSULATION MATERIAL 12 AWG CONDUCTOR SIZE NYLON JACKET MATERIAL SPOOL PACKAGE TYPE 19 STRANDS STRANDING WHITE INSULATION COLOR NOLUBE[T], SIM TECHNOLOGY[R] BRAND
$
0.28
FT
Qty:
Part #:SOU 22959101
- THHN, THWN, MTW, AWM TYPE 500 FT 500 LENGTH IN FT 109 MIL OUTER DIAMETER ANNEALED COPPER CONDUCTOR MATERIAL UL 83, UL 1063, UL 1581, UL (CANADA AND US), CSA APPROVAL 600 V VOLTAGE RATING 15 AMPERE CURRENT RATING 90 DEG C TEMPERATURE RATING 16 LB/MFT WEIGHT PVC INSULATION MATERIAL 14 AWG CONDUCTOR SIZE NYLON JACKET MATERIAL SPOOL PACKAGE TYPE 19 STRANDS STRANDING GREEN INSULATION COLOR NOLUBE[T], SIM TECHNOLOGY[R] BRAND
$
0.19
M
Qty:
Part #:SOU 22977301
- THHN, THWN, MTW, AWM TYPE 500 FT 500 LENGTH IN FT 161 MIL OUTER DIAMETER ANNEALED COPPER CONDUCTOR MATERIAL UL 83, UL 1063, UL 1581, UL (CANADA AND US), CSA APPROVAL 600 V VOLTAGE RATING 30 AMPERE CURRENT RATING 90 DEG C TEMPERATURE RATING 38 LB/MFT WEIGHT PVC INSULATION MATERIAL 10 AWG CONDUCTOR SIZE NYLON JACKET MATERIAL SPOOL PACKAGE TYPE 19 STRANDS STRANDING GREEN INSULATION COLOR NOLUBE[T], SIM TECHNOLOGY[R] BRAND
$
0.60
FT
Qty:
Part #:SOU 22979901
- THHN, THWN, MTW, AWM TYPE 500 FT 500 LENGTH IN FT 161 MIL OUTER DIAMETER ANNEALED COPPER CONDUCTOR MATERIAL UL 83, UL 1063, UL 1581, UL (CANADA AND US), CSA APPROVAL 600 V VOLTAGE RATING 30 AMPERE CURRENT RATING 90 DEG C TEMPERATURE RATING 38 LB/MFT WEIGHT PVC INSULATION MATERIAL 10 AWG CONDUCTOR SIZE NYLON JACKET MATERIAL SPOOL PACKAGE TYPE 19 STRANDS STRANDING ORANGE INSULATION COLOR NOLUBE[T], SIM TECHNOLOGY[R] BRAND
$
0.68
FT
Qty:
closeout
Part #:HOR HEX24AS
- CLOSEOUTS Only 1 Left!
- Description
Switching supply that outputs 1.5A at 24 VDC. Mounts on standard DIN-rail. Designed for the XL Family controllers.
$
128.00
Qty:
Part #:SO 44BLK250R
- SOOW Flexible Cord applications include portable tools and equipment, portable appliances, small motors and associated machinery
FeaturesExcellent resistance to oil and moisture. Good tensile strength, elongation and aging characteristics. High flexibility. Excellent abrasion resistance. Sunlight-resistant. Temperature range -40ºC to +90ºC
StandardsMSHA ApprovedRoHS Compliant
ConstructionConductors18 through 2 AWG fully annealed stranded bare copper per ASTM B-174InsulationPremium-grade, color-coded 90ºC EPDM.
Specifications
Size4 AWGNumber of Conductors4Conductor Strand119/25Insulation Thickness0.050 inchesOutside Diameter1.000 inchesWeight0.845 lbs per ftCurrent Amps60
$
12.94
M
Qty:
Part #:SO 83BLK250R
- SOOW Flexible Cord applications include portable tools and equipment, portable appliances, small motors and associated machinery
FeaturesExcellent resistance to oil and moisture. Good tensile strength, elongation and aging characteristics. High flexibility. Excellent abrasion resistance. Sunlight-resistant. Temperature range -40ºC to +90ºC
StandardsMSHA ApprovedRoHS Compliant
ConstructionConductors18 through 2 AWG fully annealed stranded bare copper per ASTM B-174InsulationPremium-grade, color-coded 90ºC EPDM.
Specifications
Size8 AWGNumber of Conductors3Conductor Strand65/26Insulation Thickness0.050 inchesOutside Diameter0.695 inchesWeight0.375 lbs per ftCurrent Amps40
Color Code3 Conductors &ndash Black, White, Green
$
5.16
M
Qty:
Part #:WIRE SO-6/3-BLK-250R
- SOOW TYPE 250 FOOT 0.98 INCH OUTER DIAMETER ANNEALED STRANDED BARE COPPER CONDUCTOR MATERIAL UL 62, CSA C22.2, MSHA APPROVAL PORTABLE TOOL AND EQUIPMENT, PORTABLE APPLIANCE, SMALL MOTOR AND ASSOCIATED MACHINERY APPLICATION 600 VOLT VOLTAGE RATING -40 TO 90 DEG C TEMPERATURE RATING 3 CONDUCTOR(S) PREMIUM GRADE EPDM INSULATION MATERIAL 6 AWG CONDUCTOR SIZE BLACK, WHITE, GREEN COLOR CODE WATER RESISTANT CAROLPRENE JACKET MATERIAL REEL PACKAGE TYPE 133/27 STRANDS STRANDING BLACK JACKET COLOR ROHS COMPLIANT CONSTRUCTIONAL FEATURE WATER/OIL/WEATHER/OZONE/MOISTURE/ABRASION/SUNLIGHT RESISTANT CURRENT RATING 55 AMP INSULATION THICKNESS 0.06 INCH
$
9.31
FT
Qty:
Part #:SOU 27035501
- TFFN, MTW/AWM TYPE 500 FT 500 LENGTH IN FT 99 MIL OUTER DIAMETER ANNEALED SOFT COPPER CONDUCTOR MATERIAL UL 66 APPROVAL 600 V VOLTAGE RATING 90 TO 105 DEG C TEMPERATURE RATING 1 CONDUCTOR(S) PVC/NYLON INSULATION MATERIAL 16 AWG CONDUCTOR SIZE SPOOL PACKAGE TYPE 26 STRANDS STRANDING BLUE JACKET COLOR SOUTHWIRE[R] BRAND
$
0.25
M
Qty:
closeout
Part #:MC CABLE43WGREENGRN
- CLOSEOUTS Only 200 Left!
- Armor
Galvanized Interlocking Steel Strip
Conductors
Stranded Copper
Conductor Insulation
THHN/THWN
Assembly Covering
Polypropylene Tape
Maximum Temperature Rating
90°C (dry)
Grounding
One grounding means &ndash may be insulated or bare
Neutral Conductor
White
Maximum Voltage Rating
600V Voltage Rating
$
8.39
FT
Qty:
Part #:SEU 666AL1000R
- Aluminum SEU cable is primarily used as panel feeder in multiple unit dwellings and for branch circuits. Maximum operating temperature is not to exceed 90°C in wet locations. Voltage rating is 600 volts.
ConstructionConductor - Aluminum SEU cable has a compact strand soft drawn 8000 series aluminum conductor, per ASTM B-801
Insulation - Aluminum SEU cable has a type XHHW-2 cross linked polyethylene (XLP) insulation. The conductors are cabled together with an aluminum alloy concentric neutral and covered with a reinforced binder tape.
Jacket - Aluminum SEU cable has a gray sunlight resistance polyvinyl chloride (PVC) jacket.
StandardsUL 44, 854Federal Specification J-C - 30BAmpacities based on National Electric Code, 2005 edition, section 310-1560°C when terminated to equipment for circuits rated 100amps or less or marked for 14ga through 1ga conductors70°C when terminated to equipment for circuits rated over 100amps or marked for conductors larger than 1ga90°C wet or dry locations For dwelling units, conductors shall be permitted at listed Ampacities to be utilized as 120/240 volt, 3-wire, single phase service conductors that supply the total load
Specifications
Insulated Conductor Size6 AWGBare Neutral Size6 AWGOutside Diameter0.458 inchesAmpacity60 amps @90°CNet Weight.143 lbs/ft
$
0.91
M
Qty:
$
2.35
M
Qty:
$
6.23
M
Qty:
Part #:HOR HE579ACM300
- The SmartBlock ACM300 is a Power and Energy Monitor that is easy to setup, and provides a variety of advanced features, including 3-phase power monitoring with three current (0-5A CTs) and voltage inputs (480V, direct connect or PTs). CsCAN CAN network connection provides a fast flexible communication path. SmartBlock package allows convenient mounting close to the source to be monitored On board relay allows load shedding, alarming or other local switching.
$
919.00
Qty:
closeout
Part #:THHN 14PE500
- CLOSEOUTS Only 500 Left!
- APPLICATIONS
Southwire Type THHN or THWN-2 conductors are primarily used in conduit and cable trays for services, feeders, and branch circuits in commercial or industrial applications as specified in the 2008 National Electrical Code. When used as Type THHN, or T90 Nylon conductor is suitable for use in dry locations at temperatures not to exceed 90 °C. When used as Type THWN-2 or TWN75, conductor is suitable for use in wet or dry locations at temperatures not to exceed 90 °C or not to exceed 75 °C when exposed to oil or coolant. When used as Type MTW, conductor is suitable for use in wet locations or when exposed to oil or coolant at temperatures not to exceed 60 °C or dry locations at temperatures not to exceed 90 °C (with ampacity limited to that for 75 °C conductor temperature per NFPA 79). Conductor temperatures not to exceed 105 °C in dry locations when rated AWM and used as appliance wiring material or when used asT90 Nylon. Voltage for all applications is 600 volts.
$
0.16
M
Qty:
$
0.68
FT
Qty:
Part #:THHN 10BE500
- APPLICATIONS
Southwire Type THHN or THWN-2 conductors are primarily used in conduit and cable trays for services, feeders, and branch circuits in commercial or industrial applications as specified in the 2008 National Electrical Code. When used as Type THHN, or T90 Nylon conductor is suitable for use in dry locations at temperatures not to exceed 90 °C. When used as Type THWN-2 or TWN75, conductor is suitable for use in wet or dry locations at temperatures not to exceed 90 °C or not to exceed 75 °C when exposed to oil or coolant. When used as Type MTW, conductor is suitable for use in wet locations or when exposed to oil or coolant at temperatures not to exceed 60 °C or dry locations at temperatures not to exceed 90 °C (with ampacity limited to that for 75 °C conductor temperature per NFPA 79). Conductor temperatures not to exceed 105 °C in dry locations when rated AWM and used as appliance wiring material or when used asT90 Nylon. Voltage for all applications is 600 volts.
$
0.42
M
Qty:
Part #:SER 40404020AL500R
-
For use in almost all applications where type SE cable is allowed
For wet or dry locations up to 90C or 194F
600-volt maximum
$
5.59