Electrical Supplies
Wire
View:
Active Filters :
- Main Category: Wire
- Main Menu: Electrical Supplies
$
1.06
M
Qty:
$
1.19
M
Qty:
Part #:USE 02BKSTAL1R
-
Cable Type Direct Burial Wire, USE-RHH-RHW
Conductor Material Aluminum
Insulation XLPE
Voltage 600V
Conductor Size 2 AWG
Conductor Strands 7-Str
Color Black
Temperature Rating 90°C
Package Type Reel
$
0.92
M
Qty:
Part #:USE 20BKSTAL5000R
- USE/RHH/RHW Underground service entrance cable in black color, has 18-Strand aluminum conductor of size 2/0 AWG. It features 80-mil cross-linked polyethylene insulation that offers resistance against moisture, heat and sunlight. Cable has voltage rating of 600 Volts and current rating of 150 Amps. It has outer diameter of 536 mil. Cable withstands temperature rating of 90 deg C in dry conditions. Cable is UL listed, RoHS/REACH compliant, NEMA rated and meets ASTM standards.
$
1.16
M
Qty:
Part #:USE 4OBKSTRAL500R
-
Cable Type Direct Burial Wire, USE-RHH-RHW
Conductor Material Copper
Insulation XLPE
Voltage 600V
Conductor Size 4 AWG
Conductor Strands 7-Str
Color Black
Temperature Rating 90°C
Package Length 500-ft
Package Type Reel
$
1.15
M
Qty:
Part #:SER 2224AL1000R
- Type SE, Style SER Service Entrance may be used as service-entrance conductors and in other applications where SE cables are permitted when installed as specified by NEC® dry locations at temperatures up to 90°C.
ConductorStranded conductors Uncoated copper per ASTM-B3, ASTM-B8, and ASTM-B787
Phase ConductorType THHN conductors Black PVC (polyvinyl chloride), rated to 90°C in wet or dry locations Jacketed with black nylon (polyamide) One phase conductor has a red stripe on its insulation surface for easy polarity identification.
Neutral ConductorWhite PVC (polyvinyl chloride), rated 90°C Jacketed with white nylon (polyamide)
Equipment Ground ConductorBare stranded copper conductor
JacketGray, sunlight-resistant PVC (polyvinyl chloride) jacket over the complete assembly
StandardsUL 83 (insulated conductors)UL 854 Service Entrance Cables, File No. 11098ASTM-B3ASTM-B8ASTM-B787Federal Specification A-A-59544NFPA70 National Electrical Code
Specifications
Insulated Conductor Size2 AWGBare Ground Size4 AWG (7)Outside Diameter0.970 inchesAmpacity amps125 @90°CNet Weight.899 lbs/ft
$
1.95
M
Qty:
Part #:SER 1113AL500R
- SER is type SE, Style R cable, used as an above ground service entrance cable, a panel feeder and in branch circuits. The cable is rated at 600 volts and 90_C for use in wet and dry locations. SER cables are LEAD FREE and RoHS compliant.
ConstructionConductor - Compact stranded AA-8000 series aluminum alloy (ACM) per ASTM B801 or B836. #8 AWG is solid AA-8000 series aluminum alloy (ACM) per ASTM B800.Insulation - Color coded cross-linked polyethylene (XLPE).Assembly - Insulated conductors are cabled with the bare ground wire. A flame retardant fiberglass reinforced binder tape assembles the core in a circular configuration.Jacket - Sunlight resistant, LEAD FREE, flame retardant, gray polyvinyl chloride (PVC) material.
Specifications
Insulated Conductor Size1 AWGInsulation Thickness0.055 inchesBare Neutral Size3 AWG (7)Jacket Thickness0.030 inchesOutside Diameter0.97 inchesAmpacity amps110Net Weight0.45 lbs per ft
$
8.44
M
Qty:
Part #:UF 123WG
-
Underground Feeder and Branch Circuit Cable
600 Volt
Copper Conductors
Sunlight, Moisture, and Fungus Resistant Overall PVC Jacket
Applications
Southwire Type UF-B cable is generally used as feeder to outside post lamps, pumps, and other loads or apparatus fed from a distribution point in an existing building as specified in the National Electrical Code.1 UF-B cable may be used underground, including direct burial. Multiple conductor UF-B cable may be used for interior branch circuit wiring in residential or agricultural buildings at conductor temperatures not to exceed 90°C (with ampacity limited to that for 60°C conductors) as specified by the National Electrical Code. UF-B can be used in applications permitted for NMC in Section 334.10(B) of the National Electrical Code. Voltage rating for UF-B cable is 600 volts.
$
0.71
M
Qty:
Part #:CRL 76812.R8.03
- MTW/TFF/AWM (UL), TEW (CSA) TYPE 500 FT 500 LENGTH IN FT 0.136 INCH OUTER DIAMETER ANNEALED STRANDED BARE COPPER CONDUCTOR MATERIAL UL, CSA APPROVAL 600 V VOLTAGE RATING 20 LB/MFT WEIGHT PVC INSULATION MATERIAL 14 AWG CONDUCTOR SIZE SPOOL PACKAGE TYPE 19/0.0159 STRANDS STRANDING CAROL[R] BRAND LENGTH IN FT - UOM FT
$
0.44
M
Qty:
Part #:CRL 03662.63.07
- BLUE COLOR 100 FT 100 LENGTH IN FT 5-15P, 5-15R CONFIGURATION UL APPROVAL SNOW BLOWER, ENGINE HEATER, BATTERY CHARGER, OUTDOOR EQUIPMENT APPLICATION 125 V VOLTAGE RATING 13 AMPERE CURRENT RATING 3 CONDUCTOR(S) 14 AWG CONDUCTOR SIZE SJEOOW CORD TYPE CAROL[R] BRAND WATTAGE 1625 W TEMPERATURE RANGE -50 TO 105 DEG C CONDUCTOR MATERIAL STRANDED BARE COPPER PACKAGE QUANTITY 2 PER CARTON LENGTH IN FT - UOM FT
$
109.06
Qty:
Part #:CRL 76832.18.01
- MTW/TFF/AWM (UL), TEW (CSA) TYPE 500 FT 500 LENGTH IN FT 0.179 INCH OUTER DIAMETER ASTM B-8 ANNEALED BARE COPPER CONDUCTOR MATERIAL UL, CSA APPROVAL 600 V VOLTAGE RATING -40 TO 90 DEG C (MTW/TFF), -20 TO 105 DEG C (AWM/TEW) TEMPERATURE RATING 42 LB/MFT WEIGHT PVC INSULATION MATERIAL 10 AWG CONDUCTOR SIZE BLACK COLOR CODE SPOOL PACKAGE TYPE 19/0.0234 STRANDS STRANDING CAROL[R] BRAND LENGTH IN FT - UOM FT
$
0.65
M
Qty:
Part #:CRL 76512.18.10
- MTW/TFF/AWM (UL), TEW (CSA) TYPE 2000 FT 2000 LENGTH IN FT 0.123 INCH OUTER DIAMETER ASTM B-8 ANNEALED BARE COPPER CONDUCTOR MATERIAL UL, CSA APPROVAL 600 V VOLTAGE RATING -40 TO 90 DEG C (MTW/TFF), -20 TO 105 DEG C (AWM/TEW) TEMPERATURE RATING 14 LB/MFT WEIGHT PVC INSULATION MATERIAL 16 AWG CONDUCTOR SIZE GRAY COLOR CODE 26/30 STRANDS STRANDING CAROL[R] BRAND LENGTH IN FT - UOM FT
$
0.16
M
Qty:
Part #:CRL 76512.18.04
- MTW/TFF/AWM (UL), TEW (CSA) TYPE 2000 FT 2000 LENGTH IN FT 0.123 INCH OUTER DIAMETER ASTM B-8 ANNEALED BARE COPPER CONDUCTOR MATERIAL UL, CSA APPROVAL 600 V VOLTAGE RATING -40 TO 90 DEG C (MTW/TFF), -20 TO 105 DEG C (AWM/TEW) TEMPERATURE RATING 14 LB/MFT WEIGHT PVC INSULATION MATERIAL 16 AWG CONDUCTOR SIZE ORANGE COLOR CODE 26/30 STRANDS STRANDING CAROL[R] BRAND LENGTH IN FT - UOM FT
$
0.30
M
Qty:
Part #:CRL 76502.18.06
- MTW/TFF/AWM (UL), TEW (CSA) TYPE 2000 FT 2000 LENGTH IN FT 0.11 INCH OUTER DIAMETER ASTM B-8 ANNEALED BARE COPPER CONDUCTOR MATERIAL UL, CSA APPROVAL 600 V VOLTAGE RATING -40 TO 90 DEG C (MTW/TFF), -20 TO 105 DEG C (AWM/TEW) TEMPERATURE RATING 10 LB/MFT WEIGHT PVC INSULATION MATERIAL 18 AWG CONDUCTOR SIZE GREEN COLOR CODE 16/30 STRANDS STRANDING CAROL[R] BRAND LENGTH IN FT - UOM FT
$
0.16
M
Qty:
Part #:CRL E1022S.30.10
- CMR, CL3R TYPE 1000 FT 0.134 INCH OUTER DIAMETER STRANDED BARE COPPER CONDUCTOR MATERIAL UL APPROVAL POWER-LIMITED CONTROL CIRCUIT, INTERCOM, AUDIO, BACKGROUND MUSIC APPLICATION 300 V VOLTAGE RATING -20 TO 75 DEG C TEMPERATURE RATING 2 CONDUCTOR(S) PVC INSULATION MATERIAL 20 AWG CONDUCTOR SIZE BLACK, RED COLOR CODE PVC JACKET MATERIAL GRAY JACKET COLOR CAROL[R] BRAND
$
0.14
Qty:
Part #:CRL 76502.18.07
- MTW/TFF/AWM (UL), TEW (CSA) TYPE 2000 FT 2000 LENGTH IN FT 0.11 INCH OUTER DIAMETER ASTM B-8 ANNEALED BARE COPPER CONDUCTOR MATERIAL UL, CSA APPROVAL 600 V VOLTAGE RATING -40 TO 90 DEG C (MTW/TFF), -20 TO 105 DEG C (AWM/TEW) TEMPERATURE RATING 10 LB/MFT WEIGHT PVC INSULATION MATERIAL 18 AWG CONDUCTOR SIZE BLUE COLOR CODE 16/30 STRANDS STRANDING CAROL[R] BRAND LENGTH IN FT - UOM FT
$
0.09
M
Qty:
Part #:UF 142WG
-
Underground Feeder and Branch Circuit Cable
600 Volt
Copper Conductors
Sunlight, Moisture, and Fungus Resistant Overall PVC Jacket
Applications
Southwire Type UF-B cable is generally used as feeder to outside post lamps, pumps, and other loads or apparatus fed from a distribution point in an existing building as specified in the National Electrical Code.1 UF-B cable may be used underground, including direct burial. Multiple conductor UF-B cable may be used for interior branch circuit wiring in residential or agricultural buildings at conductor temperatures not to exceed 90°C (with ampacity limited to that for 60°C conductors) as specified by the National Electrical Code. UF-B can be used in applications permitted for NMC in Section 334.10(B) of the National Electrical Code. Voltage rating for UF-B cable is 600 volts.
$
0.62
M
Qty:
$
2.42
M
Qty:
$
3.06
FOOT
Qty:
$
0.40
FT
Qty:
Part #:SOU 20493301
- THHN, THWN-2, MTW, AWM TYPE 500 FT 500 LENGTH IN FT 249 MIL OUTER DIAMETER ANNEALED COPPER CONDUCTOR MATERIAL UL 83, UL 1063, UL 1581, UL (CANADA AND US), CSA APPROVAL 600 V VOLTAGE RATING 55 AMPERE (60 DEG C), 65 AMPERE (75 DEG C), 75 AMPERE (90 DEG C) CURRENT RATING 90 DEG C TEMPERATURE RATING 95 LB/MFT WEIGHT PVC INSULATION MATERIAL 6 AWG CONDUCTOR SIZE NYLON JACKET MATERIAL SPOOL PACKAGE TYPE 19 STRANDS STRANDING BLACK INSULATION COLOR NOLUBE[T], SIM TECHNOLOGY[R] BRAND
$
1.24
M
Qty:
Part #:THHN 500BK500
- APPLICATIONS
Southwire Type THHN or THWN-2 conductors are primarily used in conduit and cable trays for services, feeders, and branch circuits in commercial or industrial applications as specified in the 2008 National Electrical Code. When used as Type THHN, or T90 Nylon conductor is suitable for use in dry locations at temperatures not to exceed 90 °C. When used as Type THWN-2 or TWN75, conductor is suitable for use in wet or dry locations at temperatures not to exceed 90 °C or not to exceed 75 °C when exposed to oil or coolant. When used as Type MTW, conductor is suitable for use in wet locations or when exposed to oil or coolant at temperatures not to exceed 60 °C or dry locations at temperatures not to exceed 90 °C (with ampacity limited to that for 75 °C conductor temperature per NFPA 79). Conductor temperatures not to exceed 105 °C in dry locations when rated AWM and used as appliance wiring material or when used asT90 Nylon. Voltage for all applications is 600 volts.
$
17.76
M
Qty:
Part #:SOU 22955901
- THHN, THWN, MTW, AWM TYPE 500 FT 500 LENGTH IN FT 109 MIL OUTER DIAMETER ANNEALED COPPER CONDUCTOR MATERIAL UL 83, UL 1063, UL 1581, UL (CANADA AND US), CSA APPROVAL 600 V VOLTAGE RATING 15 AMPERE CURRENT RATING 90 DEG C TEMPERATURE RATING 16 LB/MFT WEIGHT PVC INSULATION MATERIAL 14 AWG CONDUCTOR SIZE NYLON JACKET MATERIAL SPOOL PACKAGE TYPE 19 STRANDS STRANDING BLACK INSULATION COLOR NOLUBE[T], SIM TECHNOLOGY[R] BRAND
$
0.19
M
Qty:
Part #:SOU 22956701
- THHN, THWN, MTW, AWM TYPE 500 FT 500 LENGTH IN FT 109 MIL OUTER DIAMETER ANNEALED COPPER CONDUCTOR MATERIAL UL 83, UL 1063, UL 1581, UL (CANADA AND US), CSA APPROVAL 600 V VOLTAGE RATING 15 AMPERE CURRENT RATING 90 DEG C TEMPERATURE RATING 16 LB/MFT WEIGHT PVC INSULATION MATERIAL 14 AWG CONDUCTOR SIZE NYLON JACKET MATERIAL SPOOL PACKAGE TYPE 19 STRANDS STRANDING WHITE INSULATION COLOR NOLUBE[T], SIM TECHNOLOGY[R] BRAND
$
0.17
M
Qty:
Displaying: 49 - 72 of 199 Matching Items