Ceramic Tube
5 Day With Week Schedule


Displaying: 1 - 24 of 32 Matching Items
32 Items
View:
Part #:BUSS FRN-R-125

CLASS RK5 TYPE 7.13 INCH UL 248-12, CSA C22.2, CE APPROVAL 250 VOLT AC, 125 VOLT DC VOLTAGE RATING 1.56 INCH DIAMETER 200 KILOAMP SYMMETRICAL (AC), 20 KILOAMP (DC) INTERRUPTING RATING 125 AMP CURRENT RATING BLADE TERMINAL TYPE 10 SECOND TIME DELAY AT 500 PERCENT RATED LOAD, DUAL ELEMENT, NON-INDICATING CHARACTERISTICS FUSETRON[TM] BRAND APPLICATION POWER PANELBOARD, MOTOR CONTROL CENTER, COMBINATION STARTER, MACHINERY DISCONNECT FRN-R MODEL
$ 229.84
Part #:BUSS FRS-R-300

CLASS RK5 TYPE 11.63 INCH UL 248-12, CSA C22.2, CE APPROVAL 600 VOLT AC, 300 VOLT DC VOLTAGE RATING 2.34 INCH DIAMETER 200 KILOAMP SYMMETRICAL (AC), 20 KILOAMP (DC) INTERRUPTING RATING 300 AMP CURRENT RATING BLADE TERMINAL TYPE 10 SECOND TIME DELAY AT 500 PERCENT RATED LOAD, DUAL ELEMENT, NON-INDICATING CHARACTERISTICS FUSETRON[TM] BRAND APPLICATION POWER PANELBOARD, MOTOR CONTROL CENTER, COMBINATION STARTER, MACHINERY DISCONNECT FRS-R MODEL
$ 707.80
Part #:BUSS FRN-R-15

CLASS RK5 TYPE 2 INCH UL 248-12, CSA C22.2, CE APPROVAL 250 VAC/125 VDC VOLTAGE RATING 0.56 INCH DIAMETER 200 KILOAMPERE (SYMMETRICAL), 20 KILOAMPERE (DC) INTERRUPTING RATING 15 AMPERE CURRENT RATING FERRULE WITH GROOVED RING TERMINAL TYPE 10 SEC TIME DELAY (AT 500 PERCENT RATED LOAD), DUAL ELEMENT, NON-INDICATING CHARACTERISTICS FUSETRON[TM] BRAND APPLICATION POWER PANELBOARD, MOTOR CONTROL CENTER, COMBINATION STARTER, MACHINERY DISCONNECT SERIES FRN-R MODEL
$ 24.08
Part #:BUSS FRN-R-40

CLASS RK5 TYPE 3 INCH UL 248-12, CSA C22.2, CE APPROVAL 250 VAC/125 VDC VOLTAGE RATING 0.81 INCH DIAMETER 200 KILOAMPERE (SYMMETRICAL), 20 KILOAMPERE (DC) INTERRUPTING RATING 40 AMPERE CURRENT RATING FERRULE WITH GROOVED RING TERMINAL TYPE 10 SEC TIME DELAY (AT 500 PERCENT RATED LOAD), DUAL ELEMENT, NON-INDICATING CHARACTERISTICS FUSETRON[TM] BRAND APPLICATION POWER PANELBOARD, MOTOR CONTROL CENTER, COMBINATION STARTER, MACHINERY DISCONNECT SERIES FRN-R MODEL
$ 39.88
Part #:BUSS FRN-R-45

CLASS RK5 TYPE 3 INCH UL 248-12, CSA C22.2, CE APPROVAL 250 VOLT AC, 125 VOLT DC VOLTAGE RATING 0.81 INCH DIAMETER 200 KILOAMP SYMMETRICAL (AC), 20 KILOAMP (DC) INTERRUPTING RATING 45 AMP CURRENT RATING BLADE TERMINAL TYPE 10 SECOND TIME DELAY AT 500 PERCENT RATED LOAD, DUAL ELEMENT, NON-INDICATING CHARACTERISTICS FUSETRON[TM] BRAND APPLICATION POWER PANELBOARD, MOTOR CONTROL CENTER, COMBINATION STARTER, MACHINERY DISCONNECT FRN-R MODEL
$ 39.88
Part #:BUSS FRN-R-50

CLASS RK5 TYPE 3 INCH UL 248-12, CSA C22.2, CE APPROVAL 250 VOLT AC, 125 VOLT DC VOLTAGE RATING 0.81 INCH DIAMETER 200 KILOAMP SYMMETRICAL (AC), 20 KILOAMP (DC) INTERRUPTING RATING 50 AMP CURRENT RATING BLADE TERMINAL TYPE 10 SECOND TIME DELAY AT 500 PERCENT RATED LOAD, DUAL ELEMENT, NON-INDICATING CHARACTERISTICS FUSETRON[TM] BRAND APPLICATION POWER PANELBOARD, MOTOR CONTROL CENTER, COMBINATION STARTER, MACHINERY DISCONNECT FRN-R MODEL
$ 39.88
Part #:BUSS FRN-R-60

CLASS RK5 TYPE 3 INCH UL 248-12, CSA C22.2, CE APPROVAL 250 VAC/125 VDC VOLTAGE RATING 0.81 INCH DIAMETER 200 KILOAMPERE (SYMMETRICAL), 20 KILOAMPERE (DC) INTERRUPTING RATING 60 AMPERE CURRENT RATING FERRULE WITH GROOVED RING TERMINAL TYPE 10 SEC TIME DELAY (AT 500 PERCENT RATED LOAD), DUAL ELEMENT, NON-INDICATING CHARACTERISTICS FUSETRON[TM] BRAND APPLICATION POWER PANELBOARD, MOTOR CONTROL CENTER, COMBINATION STARTER, MACHINERY DISCONNECT SERIES FRN-R MODEL
$ 39.88
Part #:BUSS FRN-R-5

CLASS RK5 TYPE 2 INCH UL 248-12, CSA C22.2, CE APPROVAL 250 VOLT AC, 125 VOLT DC VOLTAGE RATING 0.56 INCH DIAMETER 200 KILOAMP SYMMETRICAL (AC), 20 KILOAMP (DC) INTERRUPTING RATING 5 AMP CURRENT RATING BLADE TERMINAL TYPE 8 SECOND TIME DELAY AT 500 PERCENT RATED LOAD, DUAL ELEMENT, NON-INDICATING CHARACTERISTICS FUSETRON[TM] BRAND APPLICATION POWER PANELBOARD, MOTOR CONTROL CENTER, COMBINATION STARTER, MACHINERY DISCONNECT FRN-R MODEL
$ 37.98
Part #:BUSS FRN-R-70

CLASS RK5 TYPE 5.88 INCH UL 248-12, CSA C22.2, CE APPROVAL 250 VAC VOLTAGE RATING 1.06 INCH DIAMETER 200 KILOAMPERE (SYMMETRICAL), 20 KILOAMPERE (DC) INTERRUPTING RATING 70 AMPERE CURRENT RATING BLADE TERMINAL TYPE 10 SEC TIME DELAY (AT 500 PERCENT RATED LOAD), DUAL ELEMENT CHARACTERISTICS FUSETRON[TM] BRAND APPLICATION POWER PANELBOARD, MOTOR CONTROL CENTER, COMBINATION STARTER, MACHINERY DISCONNECT SERIES FRN-R MODEL
$ 94.00
Part #:BUSS FRN-R-90

CLASS RK5 TYPE 5.88 INCH UL 248-12, CSA C22.2, CE APPROVAL 250 VOLT AC, 125 VOLT DC VOLTAGE RATING 1.06 INCH DIAMETER 200 KILOAMP SYMMETRICAL (AC), 20 KILOAMP (DC) INTERRUPTING RATING 90 AMP CURRENT RATING BLADE TERMINAL TYPE 10 SECOND TIME DELAY AT 500 PERCENT RATED LOAD, DUAL ELEMENT, NON-INDICATING CHARACTERISTICS FUSETRON[TM] BRAND APPLICATION POWER PANELBOARD, MOTOR CONTROL CENTER, COMBINATION STARTER, MACHINERY DISCONNECT FRN-R MODEL
$ 94.00
Part #:BUSS FRS-R-3

CLASS RK5 TYPE 5 INCH UL 248-12, CSA C22.2, CE APPROVAL 600 VAC/300 VDC VOLTAGE RATING 0.81 INCH DIAMETER 200 KILOAMPERE (SYMMETRICAL), 20 KILOAMPERE (DC) INTERRUPTING RATING 3 AMPERE CURRENT RATING FERRULE WITH GROOVED RING TERMINAL TYPE 10 SEC TIME DELAY (AT 500 PERCENT RATED LOAD), DUAL ELEMENT, NON-INDICATING CHARACTERISTICS FUSETRON[TM] BRAND APPLICATION POWER PANELBOARD, MOTOR CONTROL CENTER, COMBINATION STARTER, MACHINERY DISCONNECT SERIES FRS-R MODEL
$ 53.46
Part #:BUSS FRS-R-5

CLASS RK5 TYPE 5 INCH UL 248-12, CSA C22.2, CE APPROVAL 600 VOLT AC, 300 VOLT DC VOLTAGE RATING 0.81 INCH DIAMETER 200 KILOAMP SYMMETRICAL (AC), 20 KILOAMP (DC) INTERRUPTING RATING 5 AMP CURRENT RATING FERRULE WITH GROOVED RING TERMINAL TYPE 10 SECOND TIME DELAY AT 500 PERCENT RATED LOAD, DUAL ELEMENT, NON-INDICATING CHARACTERISTICS FUSETRON[TM] BRAND APPLICATION POWER PANELBOARD, MOTOR CONTROL CENTER, COMBINATION STARTER, MACHINERY DISCONNECT FRS-R MODEL
$ 53.46
Part #:BUSS FRS-R-8

CLASS RK5 TYPE 5 INCH UL 248-12, CSA C22.2, CE APPROVAL 600 VAC/300 VDC VOLTAGE RATING 0.81 INCH DIAMETER 200 KILOAMPERE (SYMMETRICAL), 20 KILOAMPERE (DC) INTERRUPTING RATING 8 AMPERE CURRENT RATING FERRULE WITH GROOVED RING TERMINAL TYPE 10 SEC TIME DELAY (AT 500 PERCENT RATED LOAD), DUAL ELEMENT, NON-INDICATING CHARACTERISTICS FUSETRON[TM] BRAND APPLICATION POWER PANELBOARD, MOTOR CONTROL CENTER, COMBINATION STARTER, MACHINERY DISCONNECT SERIES FRS-R MODEL
$ 53.46
Part #:BUSS FRS-R-35

CLASS RK5 TYPE 5.5 INCH UL 248-12, CSA C22.2, CE APPROVAL 600 VOLT AC, 250 VOLT DC VOLTAGE RATING 1.06 INCH DIAMETER 200 KILOAMP SYMMETRICAL (AC), 20 KILOAMP (DC) INTERRUPTING RATING 35 AMP CURRENT RATING FERRULE WITH GROOVED RING TERMINAL TYPE 10 SECOND TIME DELAY AT 500 PERCENT RATED LOAD, DUAL ELEMENT, NON-INDICATING CHARACTERISTICS FUSETRON[TM] BRAND APPLICATION POWER PANELBOARD, MOTOR CONTROL CENTER, COMBINATION STARTER, MACHINERY DISCONNECT FRS-R MODEL
$ 81.60
Part #:BUSS FRS-R-50

CLASS RK5 TYPE 5.5 INCH UL 248-12, CSA C22.2, CE APPROVAL 600 VOLT AC, 250 VOLT DC VOLTAGE RATING 1.06 INCH DIAMETER 200 KILOAMP SYMMETRICAL (AC), 20 KILOAMP (DC) INTERRUPTING RATING 50 AMP CURRENT RATING FERRULE WITH GROOVED RING TERMINAL TYPE 10 SECOND TIME DELAY AT 500 PERCENT RATED LOAD, DUAL ELEMENT, NON-INDICATING CHARACTERISTICS FUSETRON[TM] BRAND APPLICATION POWER PANELBOARD, MOTOR CONTROL CENTER, COMBINATION STARTER, MACHINERY DISCONNECT FRS-R MODEL
$ 81.60
Part #:BUSS FRS-R-250

CLASS RK5 TYPE 11.63 INCH UL 248-12, CSA C22.2, CE APPROVAL 600 VAC/300 VDC VOLTAGE RATING 2.59 INCH DIAMETER 200 KILOAMPERE (SYMMETRICAL), 20 KILOAMPERE (DC) INTERRUPTING RATING 250 AMPERE CURRENT RATING BLADE TERMINAL TYPE 10 SEC TIME DELAY (AT 500 PERCENT RATED LOAD), DUAL ELEMENT CHARACTERISTICS FUSETRON[TM] BRAND APPLICATION POWER PANELBOARD, MOTOR CONTROL CENTER, COMBINATION STARTER, MACHINERY DISCONNECT SERIES FRS-R MODEL
$ 707.80
Part #:BUSS MDA-6

MINIATURE CERAMIC TUBE TYPE 1-1/4 INCH UL 248-14, CSA, CE APPROVAL 250 VAC VOLTAGE RATING 1/4 INCH DIAMETER 200 AMPERE AT 250 VAC, 10000 AMPERE AT 125 VAC INTERRUPTING RATING 6 AMPERE CURRENT RATING FERRULE TERMINAL TYPE TIME DELAY CHARACTERISTICS MDA MODEL
$ 6.22
Part #:INT-MAT EH10

5 DAY WITH WEEK SCHEDULE TYPE DRAWN STEEL MATERIAL 5 INCH W X 3 INCH D X 7 3/4 INCH H SIZE GRAY FINISH 6 MAX. NUMBER OF OPERATIONS UL 916 APPROVAL WATER HEATER APPLICATION 120 VAC AT 50/60 HZ VOLTAGE RATING WALL MOUNTING 30 AMPERE AT 120 VAC (RESISTIVE/INDUCTIVE), 5 AMPERE AT 120 VAC (TUNGSTEN) CURRENT RATING 1 HP AT 120 VAC, 3600 W POWER RATING -40 T0 104 DEG F OPERATING TEMPERATURE SPST SWITCH TYPE ALKALINE BATTERY 3 YEAR RESERVE POWER INTERMATIC[R] BRAND WITH MANUAL EXTERNAL OVERRIDE, LOAD INDICATOR
$ 203.98
Part #:INT-MAT EH40

5 DAY WITH WEEK SCHEDULE TYPE DRAWN STEEL MATERIAL 5 INCH W X 3 INCH D X 7 3/4 INCH H SIZE GRAY FINISH 6 MAX. NUMBER OF OPERATIONS UL 916 APPROVAL WATER HEATER APPLICATION 240 VAC AT 50/60 HZ VOLTAGE RATING WALL MOUNTING 30 AMPERE AT 240 VAC (RESISTIVE/INDUCTIVE), 5 AMPERE AT 240 VAC (TUNGSTEN) CURRENT RATING 1 1/2 HP AT 240 VAC, 7200 W POWER RATING -40 T0 104 DEG F OPERATING TEMPERATURE DPST SWITCH TYPE ALKALINE BATTERY 3 YEAR RESERVE POWER INTERMATIC[R] BRAND WITH MANUAL EXTERNAL OVERRIDE, LOAD INDICATOR
$ 243.74
Part #:GE THQL1115AF

FIXED THERMAL MAGNETIC TYPE 1 INCH W X 2-3/8 INCH D X 3-9/32 INCH H SIZE AL/ALC SERIES PANELBOARD, RESIDENTIAL LOADCENTER USED ON 14 TO 10 AWG (COPPER/ALUMINUM) WIRE SIZE UL APPROVAL 120/240 VAC VOLTAGE RATING 1 INCH PLUG-IN MOUNTING 10 KILOAMPERE INTERRUPTING RATING 15 AMPERE CURRENT RATING 1 POLES ARC FAULT CIRCUIT INTERRUPTER CONSTRUCTION FEATURE TRIP TYPE NON-INTERCHANGEABLE FRAME TYPE THQL TRIP FUNCTION LI SERIES THQL MODEL
$ 179.00
Part #:GE THQL1120AF

FIXED THERMAL MAGNETIC TYPE 1 INCH W X 2-3/8 INCH D X 3-9/32 INCH H SIZE AL/ALC SERIES PANELBOARD, RESIDENTIAL LOADCENTER USED ON 14 TO 10 AWG (COPPER/ALUMINUM) WIRE SIZE UL APPROVAL 120/240 VAC VOLTAGE RATING 1 INCH PLUG-IN MOUNTING 10 KILOAMPERE INTERRUPTING RATING 20 AMPERE CURRENT RATING 1 POLES ARC FAULT CIRCUIT INTERRUPTER CONSTRUCTION FEATURE BUYLOG[TM] BRAND TRIP TYPE NON-INTERCHANGEABLE FRAME TYPE THQL TRIP FUNCTION LI THQL MODEL
$ 179.00
Part #:BUSS FRN-R-10

CLASS RK5 TYPE 2 INCH UL 248-12, CSA C22.2, CE APPROVAL 250 VOLT AC, 125 VOLT DC VOLTAGE RATING 0.56 INCH DIAMETER 200 KILOAMP SYMMETRICAL (AC), 20 KILOAMP (DC) INTERRUPTING RATING 10 AMP CURRENT RATING BLADE TERMINAL TYPE 8 SECOND TIME DELAY AT 500 PERCENT RATED LOAD, DUAL ELEMENT, NON-INDICATING CHARACTERISTICS FUSETRON[TM] BRAND APPLICATION POWER PANELBOARD, MOTOR CONTROL CENTER, COMBINATION STARTER, MACHINERY DISCONNECT FRN-R MODEL
$ 31.46
Part #:BUSS FRN-R-20

CLASS RK5 TYPE 2 INCH UL 248-12, CSA C22.2, CE APPROVAL 250 VOLT AC, 125 VOLT DC VOLTAGE RATING 0.56 INCH DIAMETER 200 KILOAMP SYMMETRICAL (AC), 20 KILOAMP (DC) INTERRUPTING RATING 20 AMP CURRENT RATING BLADE TERMINAL TYPE 8 SECOND TIME DELAY AT 500 PERCENT RATED LOAD, DUAL ELEMENT, NON-INDICATING CHARACTERISTICS FUSETRON[TM] BRAND APPLICATION POWER PANELBOARD, MOTOR CONTROL CENTER, COMBINATION STARTER, MACHINERY DISCONNECT FRN-R MODEL
$ 24.08
Part #:BUSS FRN-R-30

CLASS RK5 TYPE 2 INCH UL 248-12, CSA C22.2, CE APPROVAL 250 VAC/125 VDC VOLTAGE RATING 0.56 INCH DIAMETER 200 KILOAMPERE (SYMMETRICAL), 20 KILOAMPERE (DC) INTERRUPTING RATING 30 AMPERE CURRENT RATING FERRULE WITH GROOVED RING TERMINAL TYPE 10 SEC TIME DELAY (AT 500 PERCENT RATED LOAD), DUAL ELEMENT, NON-INDICATING CHARACTERISTICS FUSETRON[TM] BRAND APPLICATION POWER PANELBOARD, MOTOR CONTROL CENTER, COMBINATION STARTER, MACHINERY DISCONNECT SERIES FRN-R MODEL
$ 24.08
 
Displaying: 1 - 24 of 32 Matching Items