Class Rk5
Circuit Breakers, Encl & Accy


Displaying: 1 - 24 of 46 Matching Items
46 Items
View:
Part #:BUSS FRN-R-125

CLASS RK5 TYPE 7.13 INCH UL 248-12, CSA C22.2, CE APPROVAL 250 VOLT AC, 125 VOLT DC VOLTAGE RATING 1.56 INCH DIAMETER 200 KILOAMP SYMMETRICAL (AC), 20 KILOAMP (DC) INTERRUPTING RATING 125 AMP CURRENT RATING BLADE TERMINAL TYPE 10 SECOND TIME DELAY AT 500 PERCENT RATED LOAD, DUAL ELEMENT, NON-INDICATING CHARACTERISTICS FUSETRON[TM] BRAND APPLICATION POWER PANELBOARD, MOTOR CONTROL CENTER, COMBINATION STARTER, MACHINERY DISCONNECT FRN-R MODEL
$ 229.84
Part #:BUSS FRS-R-300

CLASS RK5 TYPE 11.63 INCH UL 248-12, CSA C22.2, CE APPROVAL 600 VOLT AC, 300 VOLT DC VOLTAGE RATING 2.34 INCH DIAMETER 200 KILOAMP SYMMETRICAL (AC), 20 KILOAMP (DC) INTERRUPTING RATING 300 AMP CURRENT RATING BLADE TERMINAL TYPE 10 SECOND TIME DELAY AT 500 PERCENT RATED LOAD, DUAL ELEMENT, NON-INDICATING CHARACTERISTICS FUSETRON[TM] BRAND APPLICATION POWER PANELBOARD, MOTOR CONTROL CENTER, COMBINATION STARTER, MACHINERY DISCONNECT FRS-R MODEL
$ 707.80
Part #:BUSS FRN-R-15

CLASS RK5 TYPE 2 INCH UL 248-12, CSA C22.2, CE APPROVAL 250 VAC/125 VDC VOLTAGE RATING 0.56 INCH DIAMETER 200 KILOAMPERE (SYMMETRICAL), 20 KILOAMPERE (DC) INTERRUPTING RATING 15 AMPERE CURRENT RATING FERRULE WITH GROOVED RING TERMINAL TYPE 10 SEC TIME DELAY (AT 500 PERCENT RATED LOAD), DUAL ELEMENT, NON-INDICATING CHARACTERISTICS FUSETRON[TM] BRAND APPLICATION POWER PANELBOARD, MOTOR CONTROL CENTER, COMBINATION STARTER, MACHINERY DISCONNECT SERIES FRN-R MODEL
$ 24.08
Part #:BUSS FRN-R-40

CLASS RK5 TYPE 3 INCH UL 248-12, CSA C22.2, CE APPROVAL 250 VAC/125 VDC VOLTAGE RATING 0.81 INCH DIAMETER 200 KILOAMPERE (SYMMETRICAL), 20 KILOAMPERE (DC) INTERRUPTING RATING 40 AMPERE CURRENT RATING FERRULE WITH GROOVED RING TERMINAL TYPE 10 SEC TIME DELAY (AT 500 PERCENT RATED LOAD), DUAL ELEMENT, NON-INDICATING CHARACTERISTICS FUSETRON[TM] BRAND APPLICATION POWER PANELBOARD, MOTOR CONTROL CENTER, COMBINATION STARTER, MACHINERY DISCONNECT SERIES FRN-R MODEL
$ 39.88
Part #:BUSS FRN-R-45

CLASS RK5 TYPE 3 INCH UL 248-12, CSA C22.2, CE APPROVAL 250 VOLT AC, 125 VOLT DC VOLTAGE RATING 0.81 INCH DIAMETER 200 KILOAMP SYMMETRICAL (AC), 20 KILOAMP (DC) INTERRUPTING RATING 45 AMP CURRENT RATING BLADE TERMINAL TYPE 10 SECOND TIME DELAY AT 500 PERCENT RATED LOAD, DUAL ELEMENT, NON-INDICATING CHARACTERISTICS FUSETRON[TM] BRAND APPLICATION POWER PANELBOARD, MOTOR CONTROL CENTER, COMBINATION STARTER, MACHINERY DISCONNECT FRN-R MODEL
$ 39.88
Part #:BUSS FRN-R-50

CLASS RK5 TYPE 3 INCH UL 248-12, CSA C22.2, CE APPROVAL 250 VOLT AC, 125 VOLT DC VOLTAGE RATING 0.81 INCH DIAMETER 200 KILOAMP SYMMETRICAL (AC), 20 KILOAMP (DC) INTERRUPTING RATING 50 AMP CURRENT RATING BLADE TERMINAL TYPE 10 SECOND TIME DELAY AT 500 PERCENT RATED LOAD, DUAL ELEMENT, NON-INDICATING CHARACTERISTICS FUSETRON[TM] BRAND APPLICATION POWER PANELBOARD, MOTOR CONTROL CENTER, COMBINATION STARTER, MACHINERY DISCONNECT FRN-R MODEL
$ 39.88
Part #:BUSS FRN-R-60

CLASS RK5 TYPE 3 INCH UL 248-12, CSA C22.2, CE APPROVAL 250 VAC/125 VDC VOLTAGE RATING 0.81 INCH DIAMETER 200 KILOAMPERE (SYMMETRICAL), 20 KILOAMPERE (DC) INTERRUPTING RATING 60 AMPERE CURRENT RATING FERRULE WITH GROOVED RING TERMINAL TYPE 10 SEC TIME DELAY (AT 500 PERCENT RATED LOAD), DUAL ELEMENT, NON-INDICATING CHARACTERISTICS FUSETRON[TM] BRAND APPLICATION POWER PANELBOARD, MOTOR CONTROL CENTER, COMBINATION STARTER, MACHINERY DISCONNECT SERIES FRN-R MODEL
$ 39.88
Part #:BUSS FRN-R-5

CLASS RK5 TYPE 2 INCH UL 248-12, CSA C22.2, CE APPROVAL 250 VOLT AC, 125 VOLT DC VOLTAGE RATING 0.56 INCH DIAMETER 200 KILOAMP SYMMETRICAL (AC), 20 KILOAMP (DC) INTERRUPTING RATING 5 AMP CURRENT RATING BLADE TERMINAL TYPE 8 SECOND TIME DELAY AT 500 PERCENT RATED LOAD, DUAL ELEMENT, NON-INDICATING CHARACTERISTICS FUSETRON[TM] BRAND APPLICATION POWER PANELBOARD, MOTOR CONTROL CENTER, COMBINATION STARTER, MACHINERY DISCONNECT FRN-R MODEL
$ 37.98
Part #:BUSS FRN-R-70

CLASS RK5 TYPE 5.88 INCH UL 248-12, CSA C22.2, CE APPROVAL 250 VAC VOLTAGE RATING 1.06 INCH DIAMETER 200 KILOAMPERE (SYMMETRICAL), 20 KILOAMPERE (DC) INTERRUPTING RATING 70 AMPERE CURRENT RATING BLADE TERMINAL TYPE 10 SEC TIME DELAY (AT 500 PERCENT RATED LOAD), DUAL ELEMENT CHARACTERISTICS FUSETRON[TM] BRAND APPLICATION POWER PANELBOARD, MOTOR CONTROL CENTER, COMBINATION STARTER, MACHINERY DISCONNECT SERIES FRN-R MODEL
$ 94.00
Part #:BUSS FRN-R-90

CLASS RK5 TYPE 5.88 INCH UL 248-12, CSA C22.2, CE APPROVAL 250 VOLT AC, 125 VOLT DC VOLTAGE RATING 1.06 INCH DIAMETER 200 KILOAMP SYMMETRICAL (AC), 20 KILOAMP (DC) INTERRUPTING RATING 90 AMP CURRENT RATING BLADE TERMINAL TYPE 10 SECOND TIME DELAY AT 500 PERCENT RATED LOAD, DUAL ELEMENT, NON-INDICATING CHARACTERISTICS FUSETRON[TM] BRAND APPLICATION POWER PANELBOARD, MOTOR CONTROL CENTER, COMBINATION STARTER, MACHINERY DISCONNECT FRN-R MODEL
$ 94.00
Part #:BUSS FRS-R-3

CLASS RK5 TYPE 5 INCH UL 248-12, CSA C22.2, CE APPROVAL 600 VAC/300 VDC VOLTAGE RATING 0.81 INCH DIAMETER 200 KILOAMPERE (SYMMETRICAL), 20 KILOAMPERE (DC) INTERRUPTING RATING 3 AMPERE CURRENT RATING FERRULE WITH GROOVED RING TERMINAL TYPE 10 SEC TIME DELAY (AT 500 PERCENT RATED LOAD), DUAL ELEMENT, NON-INDICATING CHARACTERISTICS FUSETRON[TM] BRAND APPLICATION POWER PANELBOARD, MOTOR CONTROL CENTER, COMBINATION STARTER, MACHINERY DISCONNECT SERIES FRS-R MODEL
$ 53.46
Part #:BUSS FRS-R-5

CLASS RK5 TYPE 5 INCH UL 248-12, CSA C22.2, CE APPROVAL 600 VOLT AC, 300 VOLT DC VOLTAGE RATING 0.81 INCH DIAMETER 200 KILOAMP SYMMETRICAL (AC), 20 KILOAMP (DC) INTERRUPTING RATING 5 AMP CURRENT RATING FERRULE WITH GROOVED RING TERMINAL TYPE 10 SECOND TIME DELAY AT 500 PERCENT RATED LOAD, DUAL ELEMENT, NON-INDICATING CHARACTERISTICS FUSETRON[TM] BRAND APPLICATION POWER PANELBOARD, MOTOR CONTROL CENTER, COMBINATION STARTER, MACHINERY DISCONNECT FRS-R MODEL
$ 53.46
Part #:BUSS FRS-R-8

CLASS RK5 TYPE 5 INCH UL 248-12, CSA C22.2, CE APPROVAL 600 VAC/300 VDC VOLTAGE RATING 0.81 INCH DIAMETER 200 KILOAMPERE (SYMMETRICAL), 20 KILOAMPERE (DC) INTERRUPTING RATING 8 AMPERE CURRENT RATING FERRULE WITH GROOVED RING TERMINAL TYPE 10 SEC TIME DELAY (AT 500 PERCENT RATED LOAD), DUAL ELEMENT, NON-INDICATING CHARACTERISTICS FUSETRON[TM] BRAND APPLICATION POWER PANELBOARD, MOTOR CONTROL CENTER, COMBINATION STARTER, MACHINERY DISCONNECT SERIES FRS-R MODEL
$ 53.46
Part #:BUSS FRS-R-35

CLASS RK5 TYPE 5.5 INCH UL 248-12, CSA C22.2, CE APPROVAL 600 VOLT AC, 250 VOLT DC VOLTAGE RATING 1.06 INCH DIAMETER 200 KILOAMP SYMMETRICAL (AC), 20 KILOAMP (DC) INTERRUPTING RATING 35 AMP CURRENT RATING FERRULE WITH GROOVED RING TERMINAL TYPE 10 SECOND TIME DELAY AT 500 PERCENT RATED LOAD, DUAL ELEMENT, NON-INDICATING CHARACTERISTICS FUSETRON[TM] BRAND APPLICATION POWER PANELBOARD, MOTOR CONTROL CENTER, COMBINATION STARTER, MACHINERY DISCONNECT FRS-R MODEL
$ 81.60
Part #:BUSS FRS-R-50

CLASS RK5 TYPE 5.5 INCH UL 248-12, CSA C22.2, CE APPROVAL 600 VOLT AC, 250 VOLT DC VOLTAGE RATING 1.06 INCH DIAMETER 200 KILOAMP SYMMETRICAL (AC), 20 KILOAMP (DC) INTERRUPTING RATING 50 AMP CURRENT RATING FERRULE WITH GROOVED RING TERMINAL TYPE 10 SECOND TIME DELAY AT 500 PERCENT RATED LOAD, DUAL ELEMENT, NON-INDICATING CHARACTERISTICS FUSETRON[TM] BRAND APPLICATION POWER PANELBOARD, MOTOR CONTROL CENTER, COMBINATION STARTER, MACHINERY DISCONNECT FRS-R MODEL
$ 81.60
Part #:BUSS FRS-R-250

CLASS RK5 TYPE 11.63 INCH UL 248-12, CSA C22.2, CE APPROVAL 600 VAC/300 VDC VOLTAGE RATING 2.59 INCH DIAMETER 200 KILOAMPERE (SYMMETRICAL), 20 KILOAMPERE (DC) INTERRUPTING RATING 250 AMPERE CURRENT RATING BLADE TERMINAL TYPE 10 SEC TIME DELAY (AT 500 PERCENT RATED LOAD), DUAL ELEMENT CHARACTERISTICS FUSETRON[TM] BRAND APPLICATION POWER PANELBOARD, MOTOR CONTROL CENTER, COMBINATION STARTER, MACHINERY DISCONNECT SERIES FRS-R MODEL
$ 707.80
Part #:3M 130C-3/4X30FT

LINERLESS, HIGH VOLTAGE INSULATING TYPE ETHYLENE PROPYLENE RUBBER MATERIAL BLACK FINISH 30 FOOT 0.75 INCH 194 DEG F MAX. CONTINUOUS TEMPERATURE 266 DEG F MAX. SHORT TERM TEMPERATURE 69 KILOVOLT VOLTAGE RATING 30 MIL THICKNESS 750 VOLT PER MIL DIELECTRIC STRENGTH SCOTCH[R] BRAND ROHS COMPLIANT BREAKING STRENGTH 7.5 INCH-POUND APPLICATION PREMIUM GRADE APPLICABLE STANDARD ASTM D-4388 130C MODEL
$ 33.03
Part #:3M 130C-2X30FT

HIGH VOLTAGE INSULATING TYPE LINERLESS, EPR MATERIAL 30 FT 2 INCH 194 DEG F MAX. CONTINUOUS TEMPERATURE 266 DEG F MAX. SHORT TERM TEMPERATURE 30 MIL THICKNESS 30 THICKNESS IN MIL 750 V PER MIL DIELECTRIC STRENGTH SCOTCH[R] BRAND APPLICABLE STANDARD ASTM D-4388, HH-I-553C PACKAGING QUANTITY 12 ROLL PER CASE 130C MODEL
$ 88.03
Part #:SIEM5 Q115

MINIATURE, THERMAL AND FIXED MAGNETIC TRIP TYPE 1 INCH WIDTH X 3 INCH DEPTH X 3-1/8 INCH HEIGHT SIZE LOAD CENTER USED ON 14 TO 6 AWG (COPPER/ALUMINUM) WIRE SIZE UL 489 APPROVAL 120 VOLT AC VOLTAGE RATING PLUG-IN MOUNTING 10 KILOAMP INTERRUPTING RATING 15 AMP AT 40 DEG C CURRENT RATING 1 POLE(S) LOAD LUG TERMINAL TYPE SPEEDFAX[TM], INSTA-WIRE BRAND FRAME TYPE QP QP MODEL
$ 78.72
Part #:SIEM5 Q230

MINIATURE, THERMAL AND FIXED MAGNETIC TRIP, COMMON TRIP TYPE 2 INCH WIDTH X 3 INCH DEPTH X 3-1/8 INCH HEIGHT SIZE LOAD CENTER USED ON 14 TO 6 AWG (COPPER/ALUMINUM) WIRE SIZE UL 489 APPROVAL 120/240 VOLT AC VOLTAGE RATING PLUG-IN MOUNTING 10 KILOAMP INTERRUPTING RATING 30 AMP AT 40 DEG C CURRENT RATING 2 POLE(S) LOAD LUG TERMINAL TYPE SPEEDFAX[TM], INSTA-WIRE BRAND FRAME TYPE QP QP MODEL
$ 161.14
Part #:GE EP101ULH3C01

Circuit Breaker, 1 Pole, C-Curve, 1A, UL489, 277V 10kA, 480Y/277VAC, 60/125VDC EP100 UL UL1077 10kA C trip curves 277/480VAC, 50/110VDC
$ 122.00
Part #:SIEM5 Q290

MINIATURE, THERMAL AND FIXED MAGNETIC TRIP, COMMON TRIP TYPE 2 INCH WIDTH X 3 INCH DEPTH X 3-1/8 INCH HEIGHT SIZE LOAD CENTER USED ON 8 TO 2/0 AWG (COPPER/ALUMINUM) WIRE SIZE UL 489 APPROVAL 120/240 VOLT AC VOLTAGE RATING PLUG-IN MOUNTING 10 KILOAMP INTERRUPTING RATING 90 AMP AT 40 DEG C CURRENT RATING 2 POLE(S) LOAD LUG TERMINAL TYPE SPEEDFAX[TM], INSTA-WIRE BRAND FRAME TYPE QP QP MODEL
$ 470.68
Part #:SIEM5 Q1515NC

MINIATURE, THERMAL AND FIXED MAGNETIC TRIP, DUPLEX TYPE 1 INCH WIDTH X 2.06 INCH DEPTH X 3.12 INCH HEIGHT SIZE LOAD CENTER USED ON 14 TO 6 AWG (COPPER/ALUMINUM) WIRE SIZE UL 489 APPROVAL 120 VOLT AC VOLTAGE RATING PLUG-IN MOUNTING 10 KILOAMP INTERRUPTING RATING 15 AMP CURRENT RATING 1 POLE(S) LOAD LUG TERMINAL TYPE SPEEDFAX[TM] BRAND FRAME TYPE QT APPLICATION HEATING, AIR CONDITIONING, REFRIGERATION QT MODEL
$ 282.08
Part #:SIEM5 B120H

MOLDED CASE, THERMAL AND FIXED MAGNETIC, BRANCH TYPE P1/P2/P3/P4/P5 PANELBOARD USED ON BOLT-ON INSTALLATION UL 489, CSA C22.2 APPROVAL LIGHTING, DISTRIBUTION APPLICATION 120 VOLT AC AT 50/60 HERTZ VOLTAGE RATING 22 KILOAMP AT 120 VOLT AC INTERRUPTING RATING 20 AMP AT 40 DEG C CURRENT RATING 1 POLE(S) SPEEDFAX[TM] BRAND FRAME TYPE BLH TERMINAL TYPE BOLT-ON OVERALL DIMENSION 1 INCH WIDTH X 3 INCH DEPTH X 3-9/16 INCH HEIGHT
$ 204.48
 