Outlet Boxes, Etc. - Non-Metallic
Dual Element Fuses
View:
Active Filters :
Part #:CARLON E989RRR-UPC
- MOLDED PPO THERMOPLASTIC MATERIAL 6 INCH 6 INCH 6 INCH DIRECT BURIAL INSTALLATION UL, CSA APPROVAL NEMA 4/4X/6P ENCLOSURE SCREW COVER TYPE 8 STANDARD PACKAGE
Part #:CARLON E381D-CAR
- T TYPE NON-METALLIC MATERIAL GRAY COLOR 1/2 INCH HUB SIZE 3 HUB(S) 1 GANG(S) UL APPROVAL SURFACE MOUNTING FEET MOUNTING HARDWARE (1) BACK, (1) EACH END HUB LOCATION ENVIRONMENTAL CONDITIONS CORROSION RESISTANT
Part #:BUSS FRN-R-125
- CLASS RK5 TYPE 7.13 INCH UL 248-12, CSA C22.2, CE APPROVAL 250 VOLT AC, 125 VOLT DC VOLTAGE RATING 1.56 INCH DIAMETER 200 KILOAMP SYMMETRICAL (AC), 20 KILOAMP (DC) INTERRUPTING RATING 125 AMP CURRENT RATING BLADE TERMINAL TYPE 10 SECOND TIME DELAY AT 500 PERCENT RATED LOAD, DUAL ELEMENT, NON-INDICATING CHARACTERISTICS FUSETRON[TM] BRAND APPLICATION POWER PANELBOARD, MOTOR CONTROL CENTER, COMBINATION STARTER, MACHINERY DISCONNECT FRN-R MODEL
$
260.64
Qty:
Part #:BUSS FRS-R-300
- CLASS RK5 TYPE 11.63 INCH UL 248-12, CSA C22.2, CE APPROVAL 600 VOLT AC, 300 VOLT DC VOLTAGE RATING 2.34 INCH DIAMETER 200 KILOAMP SYMMETRICAL (AC), 20 KILOAMP (DC) INTERRUPTING RATING 300 AMP CURRENT RATING BLADE TERMINAL TYPE 10 SECOND TIME DELAY AT 500 PERCENT RATED LOAD, DUAL ELEMENT, NON-INDICATING CHARACTERISTICS FUSETRON[TM] BRAND APPLICATION POWER PANELBOARD, MOTOR CONTROL CENTER, COMBINATION STARTER, MACHINERY DISCONNECT FRS-R MODEL
$
802.66
Qty:
Part #:BUSS LPJ-200SP
- CLASS J TYPE 5.75 INCH UL, CSA C22.2, CE APPROVAL 600 VOLT AC, 300 VOLT DC VOLTAGE RATING 1.5 INCH DIAMETER 300 KILOAMP SYMMETRICAL, 100 KILOAMP (DC) INTERRUPTING RATING 200 AMP CURRENT RATING BLADE TERMINAL TYPE 10 SECOND TIME DELAY AT 500 PERCENT RATED LOAD, DUAL ELEMENT, NON-INDICATING CHARACTERISTICS LOW-PEAK[TM] BRAND ROHS COMPLIANT CONTACT MATERIAL SILVER PLATED APPLICATION POWER PANELBOARD, BRANCH CIRCUIT BREAKER PANELBOARD MAIN, MACHINERY DISCONNECT, INDUSTRIAL CONTROL LPJ MODEL
$
599.50
Qty:
Part #:GE RT1J
- THERMAL, BIMETALLIC FIXED HEATER, ADJUSTABLE TRIP TYPE 690 V CONTACT RATING UL (CANADA AND US), CSA C22.2, CE APPROVAL 1-PHASE APPLICATION CONTACTOR/PANEL MOUNTING 3 POLE(S) SCREW TERMINAL TYPE 1NO-1NC AUXILIARY CONTACT 1.8 TO 2.7 AMPERE MOTOR FLA AUTOMATIC/MANUAL RESET TYPE YES HEATER INCLUDED COMPENSATED AMBIENT TEMPERATURE CLASS 10A TRIP CLASS APPLICABLE STANDARD IEC/EN 60947-4-1, IEC/EN 60947-5-1, VDE 0660 USED ON CL00/CL01/CL02/CL25/CL03/CL04/CL45 SERIES CONTACTOR MAXIMUM CIRCUIT BREAKER CURRENT RATING 15 AMPERE RT MODEL
$
55.00
Qty:
closeout
Part #:GE RT1L
- CLOSEOUTS Only 1 Left!
- THERMAL, BIMETALLIC FIXED HEATER, ADJUSTABLE TRIP TYPE 690 V CONTACT RATING UL (CANADA AND US), CSA C22.2, CE APPROVAL 1-PHASE APPLICATION CONTACTOR/PANEL MOUNTING 3 POLE(S) SCREW TERMINAL TYPE 1NO-1NC AUXILIARY CONTACT 4 TO 6.3 AMPERE MOTOR FLA AUTOMATIC/MANUAL RESET TYPE YES HEATER INCLUDED COMPENSATED AMBIENT TEMPERATURE CLASS 10A TRIP CLASS APPLICABLE STANDARD IEC/EN 60947-4-1, IEC/EN 60947-5-1, VDE 0660 USED ON CL00/CL01/CL02/CL25/CL03/CL04/CL45 SERIES CONTACTOR MAXIMUM CIRCUIT BREAKER CURRENT RATING 15 AMPERE RT MODEL
$
55.00
Qty:
Part #:GE RT1M
- THERMAL, BIMETALLIC FIXED HEATER, ADJUSTABLE TRIP TYPE 690 V CONTACT RATING UL (CANADA AND US), CSA C22.2, CE APPROVAL 1 PHASE APPLICATION CONTACTOR MOUNTING 3 POLE(S) SCREW TERMINAL TYPE 1NO-1NC AUXILIARY CONTACT 5.5 TO 8.5 AMPERE MOTOR FLA AUTOMATIC/MANUAL RESET TYPE YES HEATER INCLUDED COMPENSATED AMBIENT TEMPERATURE CLASS 10A TRIP CLASS APPLICABLE STANDARD IEC/EN 60947-4-1, IEC/EN 60947-5-1, VDE 0660 USED ON CL00/CL01/CL02/CL25/CL03/CL04/CL45 SERIES CONTACTOR MAXIMUM CIRCUIT BREAKER CURRENT RATING 15 AMPERE RT MODEL
$
57.00
Qty:
Part #:GE RT1P
- THERMAL, BIMETALLIC FIXED HEATER, ADJUSTABLE TRIP TYPE 690 V CONTACT RATING UL (CANADA AND US), CSA C22.2, CE APPROVAL 1-PHASE APPLICATION CONTACTOR/PANEL MOUNTING 3 POLE(S) SCREW TERMINAL TYPE 1NO-1NC AUXILIARY CONTACT 10 TO 16 AMPERE MOTOR FLA AUTOMATIC/MANUAL RESET TYPE YES HEATER INCLUDED COMPENSATED AMBIENT TEMPERATURE CLASS 10A TRIP CLASS APPLICABLE STANDARD IEC/EN 60947-4-1, IEC/EN 60947-5-1, VDE 0660 USED ON CL00/CL01/CL02/CL25/CL03/CL04/CL45 SERIES CONTACTOR MAXIMUM CIRCUIT BREAKER CURRENT RATING 35 AMPERE RT MODEL
$
57.00
Qty:
Part #:ARL FS8141
- PLASTIC MATERIAL TEXTURED FINISH 3.312 INCH 3.312 WIDTH IN INCH 5.093 INCH 5.093 HEIGHT IN INCH 2.056 INCH 2.056 DEPTH IN INCH 1 GANG(S) UL APPROVAL 18.6 CU INCH CAPACITY 1/2 INCH LAP STANDARD PACKAGE 25 DEPTH IN INCH - UOM IN HEIGHT IN INCH - UOM IN WIDTH IN INCH - UOM IN FS MODEL
$
7.05
Qty:
Part #:ARL MB8
- CEILING FAN/FIXTURE TYPE 0.74 INCH .74 DEPTH IN INCH 8 DIAMETER IN INCH ROUND SHAPE 10 APPROVAL 8 INCH DIAMETER (2) #10 X 3 INCH WOOD SCREW, (1) #8 X 1 1/2 INCH WOOD SCREW MOUNTING UL, CSA STANDARD PACKAGE 6.1 CU INCH CAPACITY DEPTH IN INCH - UOM IN DIAMETER IN INCH - UOM IN
$
22.56
Qty:
Part #:BUSS FRN-R-15
- CLASS RK5 TYPE 2 INCH UL 248-12, CSA C22.2, CE APPROVAL 250 VAC/125 VDC VOLTAGE RATING 0.56 INCH DIAMETER 200 KILOAMPERE (SYMMETRICAL), 20 KILOAMPERE (DC) INTERRUPTING RATING 15 AMPERE CURRENT RATING FERRULE WITH GROOVED RING TERMINAL TYPE 10 SEC TIME DELAY (AT 500 PERCENT RATED LOAD), DUAL ELEMENT, NON-INDICATING CHARACTERISTICS FUSETRON[TM] BRAND APPLICATION POWER PANELBOARD, MOTOR CONTROL CENTER, COMBINATION STARTER, MACHINERY DISCONNECT SERIES FRN-R MODEL
$
27.30
Qty:
Part #:BUSS FRN-R-40
- CLASS RK5 TYPE 3 INCH UL 248-12, CSA C22.2, CE APPROVAL 250 VAC/125 VDC VOLTAGE RATING 0.81 INCH DIAMETER 200 KILOAMPERE (SYMMETRICAL), 20 KILOAMPERE (DC) INTERRUPTING RATING 40 AMPERE CURRENT RATING FERRULE WITH GROOVED RING TERMINAL TYPE 10 SEC TIME DELAY (AT 500 PERCENT RATED LOAD), DUAL ELEMENT, NON-INDICATING CHARACTERISTICS FUSETRON[TM] BRAND APPLICATION POWER PANELBOARD, MOTOR CONTROL CENTER, COMBINATION STARTER, MACHINERY DISCONNECT SERIES FRN-R MODEL
$
45.22
Qty:
Part #:BUSS FRN-R-45
- CLASS RK5 TYPE 3 INCH UL 248-12, CSA C22.2, CE APPROVAL 250 VOLT AC, 125 VOLT DC VOLTAGE RATING 0.81 INCH DIAMETER 200 KILOAMP SYMMETRICAL (AC), 20 KILOAMP (DC) INTERRUPTING RATING 45 AMP CURRENT RATING BLADE TERMINAL TYPE 10 SECOND TIME DELAY AT 500 PERCENT RATED LOAD, DUAL ELEMENT, NON-INDICATING CHARACTERISTICS FUSETRON[TM] BRAND APPLICATION POWER PANELBOARD, MOTOR CONTROL CENTER, COMBINATION STARTER, MACHINERY DISCONNECT FRN-R MODEL
$
45.22
Qty:
Part #:BUSS FRN-R-50
- CLASS RK5 TYPE 3 INCH UL 248-12, CSA C22.2, CE APPROVAL 250 VOLT AC, 125 VOLT DC VOLTAGE RATING 0.81 INCH DIAMETER 200 KILOAMP SYMMETRICAL (AC), 20 KILOAMP (DC) INTERRUPTING RATING 50 AMP CURRENT RATING BLADE TERMINAL TYPE 10 SECOND TIME DELAY AT 500 PERCENT RATED LOAD, DUAL ELEMENT, NON-INDICATING CHARACTERISTICS FUSETRON[TM] BRAND APPLICATION POWER PANELBOARD, MOTOR CONTROL CENTER, COMBINATION STARTER, MACHINERY DISCONNECT FRN-R MODEL
$
45.22
Qty:
Part #:BUSS FRN-R-60
- CLASS RK5 TYPE 3 INCH UL 248-12, CSA C22.2, CE APPROVAL 250 VAC/125 VDC VOLTAGE RATING 0.81 INCH DIAMETER 200 KILOAMPERE (SYMMETRICAL), 20 KILOAMPERE (DC) INTERRUPTING RATING 60 AMPERE CURRENT RATING FERRULE WITH GROOVED RING TERMINAL TYPE 10 SEC TIME DELAY (AT 500 PERCENT RATED LOAD), DUAL ELEMENT, NON-INDICATING CHARACTERISTICS FUSETRON[TM] BRAND APPLICATION POWER PANELBOARD, MOTOR CONTROL CENTER, COMBINATION STARTER, MACHINERY DISCONNECT SERIES FRN-R MODEL
$
45.22
Qty:
Part #:BUSS SC-20
- CLASS G TYPE 1.419 INCH UL 248-5, CSA, CE APPROVAL 600 VAC/170 VDC VOLTAGE RATING 0.41 INCH DIAMETER 100000 AMPERE (SYMMETRICAL), 10000 AMPERE (DC) INTERRUPTING RATING 20 AMPERE CURRENT RATING FERRULE TERMINAL TYPE TIME DELAY CHARACTERISTICS BUSSMANN. BRAND CURRENT LIMITING MELAMINE TUBE SC MODEL
$
27.28
Qty:
Part #:BUSS FRN-R-5
- CLASS RK5 TYPE 2 INCH UL 248-12, CSA C22.2, CE APPROVAL 250 VOLT AC, 125 VOLT DC VOLTAGE RATING 0.56 INCH DIAMETER 200 KILOAMP SYMMETRICAL (AC), 20 KILOAMP (DC) INTERRUPTING RATING 5 AMP CURRENT RATING BLADE TERMINAL TYPE 8 SECOND TIME DELAY AT 500 PERCENT RATED LOAD, DUAL ELEMENT, NON-INDICATING CHARACTERISTICS FUSETRON[TM] BRAND APPLICATION POWER PANELBOARD, MOTOR CONTROL CENTER, COMBINATION STARTER, MACHINERY DISCONNECT FRN-R MODEL
$
43.08
Qty:
Part #:BUSS FRN-R-70
- CLASS RK5 TYPE 5.88 INCH UL 248-12, CSA C22.2, CE APPROVAL 250 VAC VOLTAGE RATING 1.06 INCH DIAMETER 200 KILOAMPERE (SYMMETRICAL), 20 KILOAMPERE (DC) INTERRUPTING RATING 70 AMPERE CURRENT RATING BLADE TERMINAL TYPE 10 SEC TIME DELAY (AT 500 PERCENT RATED LOAD), DUAL ELEMENT CHARACTERISTICS FUSETRON[TM] BRAND APPLICATION POWER PANELBOARD, MOTOR CONTROL CENTER, COMBINATION STARTER, MACHINERY DISCONNECT SERIES FRN-R MODEL
$
106.58
Qty:
Part #:BUSS FRN-R-90
- CLASS RK5 TYPE 5.88 INCH UL 248-12, CSA C22.2, CE APPROVAL 250 VOLT AC, 125 VOLT DC VOLTAGE RATING 1.06 INCH DIAMETER 200 KILOAMP SYMMETRICAL (AC), 20 KILOAMP (DC) INTERRUPTING RATING 90 AMP CURRENT RATING BLADE TERMINAL TYPE 10 SECOND TIME DELAY AT 500 PERCENT RATED LOAD, DUAL ELEMENT, NON-INDICATING CHARACTERISTICS FUSETRON[TM] BRAND APPLICATION POWER PANELBOARD, MOTOR CONTROL CENTER, COMBINATION STARTER, MACHINERY DISCONNECT FRN-R MODEL
$
106.58
Qty:
closeout
Part #:BUSS FRS-R-3
- CLOSEOUTS Only 7 Left!
- CLASS RK5 TYPE 5 INCH UL 248-12, CSA C22.2, CE APPROVAL 600 VAC/300 VDC VOLTAGE RATING 0.81 INCH DIAMETER 200 KILOAMPERE (SYMMETRICAL), 20 KILOAMPERE (DC) INTERRUPTING RATING 3 AMPERE CURRENT RATING FERRULE WITH GROOVED RING TERMINAL TYPE 10 SEC TIME DELAY (AT 500 PERCENT RATED LOAD), DUAL ELEMENT, NON-INDICATING CHARACTERISTICS FUSETRON[TM] BRAND APPLICATION POWER PANELBOARD, MOTOR CONTROL CENTER, COMBINATION STARTER, MACHINERY DISCONNECT SERIES FRS-R MODEL
$
60.62
Qty:
Part #:BUSS FRS-R-5
- CLASS RK5 TYPE 5 INCH UL 248-12, CSA C22.2, CE APPROVAL 600 VOLT AC, 300 VOLT DC VOLTAGE RATING 0.81 INCH DIAMETER 200 KILOAMP SYMMETRICAL (AC), 20 KILOAMP (DC) INTERRUPTING RATING 5 AMP CURRENT RATING FERRULE WITH GROOVED RING TERMINAL TYPE 10 SECOND TIME DELAY AT 500 PERCENT RATED LOAD, DUAL ELEMENT, NON-INDICATING CHARACTERISTICS FUSETRON[TM] BRAND APPLICATION POWER PANELBOARD, MOTOR CONTROL CENTER, COMBINATION STARTER, MACHINERY DISCONNECT FRS-R MODEL
$
60.62
Qty:
Part #:BUSS FRS-R-8
- CLASS RK5 TYPE 5 INCH UL 248-12, CSA C22.2, CE APPROVAL 600 VAC/300 VDC VOLTAGE RATING 0.81 INCH DIAMETER 200 KILOAMPERE (SYMMETRICAL), 20 KILOAMPERE (DC) INTERRUPTING RATING 8 AMPERE CURRENT RATING FERRULE WITH GROOVED RING TERMINAL TYPE 10 SEC TIME DELAY (AT 500 PERCENT RATED LOAD), DUAL ELEMENT, NON-INDICATING CHARACTERISTICS FUSETRON[TM] BRAND APPLICATION POWER PANELBOARD, MOTOR CONTROL CENTER, COMBINATION STARTER, MACHINERY DISCONNECT SERIES FRS-R MODEL
$
60.62
Qty:
Part #:BUSS FRS-R-35
- CLASS RK5 TYPE 5.5 INCH UL 248-12, CSA C22.2, CE APPROVAL 600 VOLT AC, 250 VOLT DC VOLTAGE RATING 1.06 INCH DIAMETER 200 KILOAMP SYMMETRICAL (AC), 20 KILOAMP (DC) INTERRUPTING RATING 35 AMP CURRENT RATING FERRULE WITH GROOVED RING TERMINAL TYPE 10 SECOND TIME DELAY AT 500 PERCENT RATED LOAD, DUAL ELEMENT, NON-INDICATING CHARACTERISTICS FUSETRON[TM] BRAND APPLICATION POWER PANELBOARD, MOTOR CONTROL CENTER, COMBINATION STARTER, MACHINERY DISCONNECT FRS-R MODEL
$
92.52
Qty:
Displaying: 1 - 24 of 80 Matching Items