Molded Case, Thermal Magnetic, Internal Common Trip
Class Rk5


Displaying: 1 - 24 of 34 Matching Items
34 Items
View:
Part #:BUSS FRN-R-125

CLASS RK5 TYPE 7.13 INCH UL 248-12, CSA C22.2, CE APPROVAL 250 VOLT AC, 125 VOLT DC VOLTAGE RATING 1.56 INCH DIAMETER 200 KILOAMP SYMMETRICAL (AC), 20 KILOAMP (DC) INTERRUPTING RATING 125 AMP CURRENT RATING BLADE TERMINAL TYPE 10 SECOND TIME DELAY AT 500 PERCENT RATED LOAD, DUAL ELEMENT, NON-INDICATING CHARACTERISTICS FUSETRON[TM] BRAND APPLICATION POWER PANELBOARD, MOTOR CONTROL CENTER, COMBINATION STARTER, MACHINERY DISCONNECT FRN-R MODEL
$ 235.45
Part #:BUSS FRS-R-300

CLASS RK5 TYPE 11.63 INCH UL 248-12, CSA C22.2, CE APPROVAL 600 VOLT AC, 300 VOLT DC VOLTAGE RATING 2.34 INCH DIAMETER 200 KILOAMP SYMMETRICAL (AC), 20 KILOAMP (DC) INTERRUPTING RATING 300 AMP CURRENT RATING BLADE TERMINAL TYPE 10 SECOND TIME DELAY AT 500 PERCENT RATED LOAD, DUAL ELEMENT, NON-INDICATING CHARACTERISTICS FUSETRON[TM] BRAND APPLICATION POWER PANELBOARD, MOTOR CONTROL CENTER, COMBINATION STARTER, MACHINERY DISCONNECT FRS-R MODEL
$ 725.07
Part #:BUSS FRN-R-15

CLASS RK5 TYPE 2 INCH UL 248-12, CSA C22.2, CE APPROVAL 250 VAC/125 VDC VOLTAGE RATING 0.56 INCH DIAMETER 200 KILOAMPERE (SYMMETRICAL), 20 KILOAMPERE (DC) INTERRUPTING RATING 15 AMPERE CURRENT RATING FERRULE WITH GROOVED RING TERMINAL TYPE 10 SEC TIME DELAY (AT 500 PERCENT RATED LOAD), DUAL ELEMENT, NON-INDICATING CHARACTERISTICS FUSETRON[TM] BRAND APPLICATION POWER PANELBOARD, MOTOR CONTROL CENTER, COMBINATION STARTER, MACHINERY DISCONNECT SERIES FRN-R MODEL
$ 24.68
Part #:BUSS FRN-R-40

CLASS RK5 TYPE 3 INCH UL 248-12, CSA C22.2, CE APPROVAL 250 VAC/125 VDC VOLTAGE RATING 0.81 INCH DIAMETER 200 KILOAMPERE (SYMMETRICAL), 20 KILOAMPERE (DC) INTERRUPTING RATING 40 AMPERE CURRENT RATING FERRULE WITH GROOVED RING TERMINAL TYPE 10 SEC TIME DELAY (AT 500 PERCENT RATED LOAD), DUAL ELEMENT, NON-INDICATING CHARACTERISTICS FUSETRON[TM] BRAND APPLICATION POWER PANELBOARD, MOTOR CONTROL CENTER, COMBINATION STARTER, MACHINERY DISCONNECT SERIES FRN-R MODEL
$ 40.85
Part #:BUSS FRN-R-45

CLASS RK5 TYPE 3 INCH UL 248-12, CSA C22.2, CE APPROVAL 250 VOLT AC, 125 VOLT DC VOLTAGE RATING 0.81 INCH DIAMETER 200 KILOAMP SYMMETRICAL (AC), 20 KILOAMP (DC) INTERRUPTING RATING 45 AMP CURRENT RATING BLADE TERMINAL TYPE 10 SECOND TIME DELAY AT 500 PERCENT RATED LOAD, DUAL ELEMENT, NON-INDICATING CHARACTERISTICS FUSETRON[TM] BRAND APPLICATION POWER PANELBOARD, MOTOR CONTROL CENTER, COMBINATION STARTER, MACHINERY DISCONNECT FRN-R MODEL
$ 40.85
Part #:BUSS FRN-R-50

CLASS RK5 TYPE 3 INCH UL 248-12, CSA C22.2, CE APPROVAL 250 VOLT AC, 125 VOLT DC VOLTAGE RATING 0.81 INCH DIAMETER 200 KILOAMP SYMMETRICAL (AC), 20 KILOAMP (DC) INTERRUPTING RATING 50 AMP CURRENT RATING BLADE TERMINAL TYPE 10 SECOND TIME DELAY AT 500 PERCENT RATED LOAD, DUAL ELEMENT, NON-INDICATING CHARACTERISTICS FUSETRON[TM] BRAND APPLICATION POWER PANELBOARD, MOTOR CONTROL CENTER, COMBINATION STARTER, MACHINERY DISCONNECT FRN-R MODEL
$ 40.85
Part #:BUSS FRN-R-60

CLASS RK5 TYPE 3 INCH UL 248-12, CSA C22.2, CE APPROVAL 250 VAC/125 VDC VOLTAGE RATING 0.81 INCH DIAMETER 200 KILOAMPERE (SYMMETRICAL), 20 KILOAMPERE (DC) INTERRUPTING RATING 60 AMPERE CURRENT RATING FERRULE WITH GROOVED RING TERMINAL TYPE 10 SEC TIME DELAY (AT 500 PERCENT RATED LOAD), DUAL ELEMENT, NON-INDICATING CHARACTERISTICS FUSETRON[TM] BRAND APPLICATION POWER PANELBOARD, MOTOR CONTROL CENTER, COMBINATION STARTER, MACHINERY DISCONNECT SERIES FRN-R MODEL
$ 40.85
Part #:BUSS FRN-R-5

CLASS RK5 TYPE 2 INCH UL 248-12, CSA C22.2, CE APPROVAL 250 VOLT AC, 125 VOLT DC VOLTAGE RATING 0.56 INCH DIAMETER 200 KILOAMP SYMMETRICAL (AC), 20 KILOAMP (DC) INTERRUPTING RATING 5 AMP CURRENT RATING BLADE TERMINAL TYPE 8 SECOND TIME DELAY AT 500 PERCENT RATED LOAD, DUAL ELEMENT, NON-INDICATING CHARACTERISTICS FUSETRON[TM] BRAND APPLICATION POWER PANELBOARD, MOTOR CONTROL CENTER, COMBINATION STARTER, MACHINERY DISCONNECT FRN-R MODEL
$ 38.91
Part #:BUSS FRN-R-70

CLASS RK5 TYPE 5.88 INCH UL 248-12, CSA C22.2, CE APPROVAL 250 VAC VOLTAGE RATING 1.06 INCH DIAMETER 200 KILOAMPERE (SYMMETRICAL), 20 KILOAMPERE (DC) INTERRUPTING RATING 70 AMPERE CURRENT RATING BLADE TERMINAL TYPE 10 SEC TIME DELAY (AT 500 PERCENT RATED LOAD), DUAL ELEMENT CHARACTERISTICS FUSETRON[TM] BRAND APPLICATION POWER PANELBOARD, MOTOR CONTROL CENTER, COMBINATION STARTER, MACHINERY DISCONNECT SERIES FRN-R MODEL
$ 96.29
Part #:BUSS FRN-R-90

CLASS RK5 TYPE 5.88 INCH UL 248-12, CSA C22.2, CE APPROVAL 250 VOLT AC, 125 VOLT DC VOLTAGE RATING 1.06 INCH DIAMETER 200 KILOAMP SYMMETRICAL (AC), 20 KILOAMP (DC) INTERRUPTING RATING 90 AMP CURRENT RATING BLADE TERMINAL TYPE 10 SECOND TIME DELAY AT 500 PERCENT RATED LOAD, DUAL ELEMENT, NON-INDICATING CHARACTERISTICS FUSETRON[TM] BRAND APPLICATION POWER PANELBOARD, MOTOR CONTROL CENTER, COMBINATION STARTER, MACHINERY DISCONNECT FRN-R MODEL
$ 111.60
Part #:BUSS FRS-R-3

CLASS RK5 TYPE 5 INCH UL 248-12, CSA C22.2, CE APPROVAL 600 VAC/300 VDC VOLTAGE RATING 0.81 INCH DIAMETER 200 KILOAMPERE (SYMMETRICAL), 20 KILOAMPERE (DC) INTERRUPTING RATING 3 AMPERE CURRENT RATING FERRULE WITH GROOVED RING TERMINAL TYPE 10 SEC TIME DELAY (AT 500 PERCENT RATED LOAD), DUAL ELEMENT, NON-INDICATING CHARACTERISTICS FUSETRON[TM] BRAND APPLICATION POWER PANELBOARD, MOTOR CONTROL CENTER, COMBINATION STARTER, MACHINERY DISCONNECT SERIES FRS-R MODEL
$ 54.77
Part #:BUSS FRS-R-5

CLASS RK5 TYPE 5 INCH UL 248-12, CSA C22.2, CE APPROVAL 600 VOLT AC, 300 VOLT DC VOLTAGE RATING 0.81 INCH DIAMETER 200 KILOAMP SYMMETRICAL (AC), 20 KILOAMP (DC) INTERRUPTING RATING 5 AMP CURRENT RATING FERRULE WITH GROOVED RING TERMINAL TYPE 10 SECOND TIME DELAY AT 500 PERCENT RATED LOAD, DUAL ELEMENT, NON-INDICATING CHARACTERISTICS FUSETRON[TM] BRAND APPLICATION POWER PANELBOARD, MOTOR CONTROL CENTER, COMBINATION STARTER, MACHINERY DISCONNECT FRS-R MODEL
$ 54.77
Part #:BUSS FRS-R-8

CLASS RK5 TYPE 5 INCH UL 248-12, CSA C22.2, CE APPROVAL 600 VAC/300 VDC VOLTAGE RATING 0.81 INCH DIAMETER 200 KILOAMPERE (SYMMETRICAL), 20 KILOAMPERE (DC) INTERRUPTING RATING 8 AMPERE CURRENT RATING FERRULE WITH GROOVED RING TERMINAL TYPE 10 SEC TIME DELAY (AT 500 PERCENT RATED LOAD), DUAL ELEMENT, NON-INDICATING CHARACTERISTICS FUSETRON[TM] BRAND APPLICATION POWER PANELBOARD, MOTOR CONTROL CENTER, COMBINATION STARTER, MACHINERY DISCONNECT SERIES FRS-R MODEL
$ 54.77
Part #:BUSS FRS-R-35

CLASS RK5 TYPE 5.5 INCH UL 248-12, CSA C22.2, CE APPROVAL 600 VOLT AC, 250 VOLT DC VOLTAGE RATING 1.06 INCH DIAMETER 200 KILOAMP SYMMETRICAL (AC), 20 KILOAMP (DC) INTERRUPTING RATING 35 AMP CURRENT RATING FERRULE WITH GROOVED RING TERMINAL TYPE 10 SECOND TIME DELAY AT 500 PERCENT RATED LOAD, DUAL ELEMENT, NON-INDICATING CHARACTERISTICS FUSETRON[TM] BRAND APPLICATION POWER PANELBOARD, MOTOR CONTROL CENTER, COMBINATION STARTER, MACHINERY DISCONNECT FRS-R MODEL
$ 83.58
Part #:BUSS FRS-R-50

CLASS RK5 TYPE 5.5 INCH UL 248-12, CSA C22.2, CE APPROVAL 600 VOLT AC, 250 VOLT DC VOLTAGE RATING 1.06 INCH DIAMETER 200 KILOAMP SYMMETRICAL (AC), 20 KILOAMP (DC) INTERRUPTING RATING 50 AMP CURRENT RATING FERRULE WITH GROOVED RING TERMINAL TYPE 10 SECOND TIME DELAY AT 500 PERCENT RATED LOAD, DUAL ELEMENT, NON-INDICATING CHARACTERISTICS FUSETRON[TM] BRAND APPLICATION POWER PANELBOARD, MOTOR CONTROL CENTER, COMBINATION STARTER, MACHINERY DISCONNECT FRS-R MODEL
$ 83.58
Part #:BUSS FRS-R-250

CLASS RK5 TYPE 11.63 INCH UL 248-12, CSA C22.2, CE APPROVAL 600 VAC/300 VDC VOLTAGE RATING 2.59 INCH DIAMETER 200 KILOAMPERE (SYMMETRICAL), 20 KILOAMPERE (DC) INTERRUPTING RATING 250 AMPERE CURRENT RATING BLADE TERMINAL TYPE 10 SEC TIME DELAY (AT 500 PERCENT RATED LOAD), DUAL ELEMENT CHARACTERISTICS FUSETRON[TM] BRAND APPLICATION POWER PANELBOARD, MOTOR CONTROL CENTER, COMBINATION STARTER, MACHINERY DISCONNECT SERIES FRS-R MODEL
$ 725.07
Part #:GE THQL2120

MOLDED CASE, FIXED THERMAL MAGNETIC, INTERNAL COMMON TRIP TYPE 2 INCH WIDTH X 2-3/8 INCH DEPTH X 3-9/32 INCH HEIGHT SIZE AL SERIES PANELBOARD USED ON 14 TO 8 AWG (COPPER), 12 TO 8 AWG (ALUMINUM) WIRE SIZE UL APPROVAL 120/240 VOLT AC VOLTAGE RATING 1 INCH PLUG-IN MOUNTING 10 KILOAMP INTERRUPTING RATING 20 AMP CURRENT RATING 2 POLE(S) COPPER/ALUMINUM LOAD LUG TERMINAL TYPE TRIP TYPE NON-INTERCHANGEABLE FRAME TYPE THQL TRIP FUNCTION LI APPLICATION HEATING, AIR CONDITIONING, REFRIGERATION THQL MODEL
$ 48.00
Part #:GE THQL2140

MOLDED CASE, FIXED THERMAL MAGNETIC, INTERNAL COMMON TRIP TYPE 2 INCH WIDTH X 2-3/8 INCH DEPTH X 3-9/32 INCH HEIGHT SIZE AL SERIES PANELBOARD USED ON 8 TO 3 AWG (COPPER/ALUMINUM) WIRE SIZE UL APPROVAL 120/240 VOLT AC VOLTAGE RATING 1 INCH PLUG-IN MOUNTING 10 KILOAMP INTERRUPTING RATING 40 AMP CURRENT RATING 2 POLE(S) COPPER/ALUMINUM LOAD LUG TERMINAL TYPE TRIP TYPE NON-INTERCHANGEABLE FRAME TYPE THQL TRIP FUNCTION LI APPLICATION HEATING, AIR CONDITIONING, REFRIGERATION THQL MODEL
$ 53.00
Part #:GE THQB2115

MOLDED CASE, FIXED THERMAL MAGNETIC, INTERNAL COMMON TRIP TYPE 2 INCH W X 2-3/8 INCH D X 3-9/32 INCH H SIZE AQ SERIES PANELBOARD USED ON 14 TO 8 AWG (COPPER)/12 TO 8 AWG (ALUMINUM) WIRE SIZE UL APPROVAL 120/240 VAC VOLTAGE RATING 1 INCH BOLT-ON MOUNTING 10 KILOAMPERE INTERRUPTING RATING 15 AMPERE CURRENT RATING 2 POLE(S) COPPER/ALUMINUM LOAD LUG, BOLT-ON TERMINAL TYPE TRIP TYPE NON-INTERCHANGEABLE FRAME TYPE THQB TRIP FUNCTION LI APPLICATION HEATING, AIR CONDITIONING, REFRIGERATION SERIES THQB MODEL
$ 78.00
Part #:GE THQB2150

MOLDED CASE, FIXED THERMAL MAGNETIC, INTERNAL COMMON TRIP TYPE 2 INCH W X 2-3/8 INCH D X 3-9/32 INCH H SIZE AQ SERIES PANELBOARD USED ON 8 TO 3 AWG (COPPER/ALUMINUM) WIRE SIZE UL APPROVAL 120/240 VAC VOLTAGE RATING 1 INCH BOLT-ON MOUNTING 10 KILOAMPERE INTERRUPTING RATING 50 AMPERE CURRENT RATING 2 POLE(S) COPPER/ALUMINUM LOAD LUG, BOLT-ON TERMINAL TYPE TRIP TYPE NON-INTERCHANGEABLE FRAME TYPE THQB TRIP FUNCTION LI APPLICATION HEATING, AIR CONDITIONING, REFRIGERATION SERIES THQB MODEL
$ 78.00
Part #:GE THQP220

MOLDED CASE, FIXED THERMAL MAGNETIC, INTERNAL COMMON TRIP TYPE 1 INCH WIDTH X 2-3/8 INCH DEPTH X 3-9/32 INCH HEIGHT SIZE 14 TO 8 AWG (COPPER), 12 TO 8 AWG (ALUMINUM) WIRE SIZE UL APPROVAL 120/240 VOLT AC VOLTAGE RATING 1/2 INCH PLUG-IN MOUNTING 10 KILOAMP INTERRUPTING RATING 20 AMP CURRENT RATING 2 POLE(S) COPPER/ALUMINUM LOAD LUG TERMINAL TYPE TRIP TYPE NON-INTERCHANGEABLE FRAME TYPE THQP TRIP FUNCTION LI APPLICATION HEATING, AIR CONDITIONING, REFRIGERATION THQP MODEL
$ 48.00
Part #:BUSS FRN-R-10

CLASS RK5 TYPE 2 INCH UL 248-12, CSA C22.2, CE APPROVAL 250 VOLT AC, 125 VOLT DC VOLTAGE RATING 0.56 INCH DIAMETER 200 KILOAMP SYMMETRICAL (AC), 20 KILOAMP (DC) INTERRUPTING RATING 10 AMP CURRENT RATING BLADE TERMINAL TYPE 8 SECOND TIME DELAY AT 500 PERCENT RATED LOAD, DUAL ELEMENT, NON-INDICATING CHARACTERISTICS FUSETRON[TM] BRAND APPLICATION POWER PANELBOARD, MOTOR CONTROL CENTER, COMBINATION STARTER, MACHINERY DISCONNECT FRN-R MODEL
$ 32.24
Part #:BUSS FRN-R-20

CLASS RK5 TYPE 2 INCH UL 248-12, CSA C22.2, CE APPROVAL 250 VOLT AC, 125 VOLT DC VOLTAGE RATING 0.56 INCH DIAMETER 200 KILOAMP SYMMETRICAL (AC), 20 KILOAMP (DC) INTERRUPTING RATING 20 AMP CURRENT RATING BLADE TERMINAL TYPE 8 SECOND TIME DELAY AT 500 PERCENT RATED LOAD, DUAL ELEMENT, NON-INDICATING CHARACTERISTICS FUSETRON[TM] BRAND APPLICATION POWER PANELBOARD, MOTOR CONTROL CENTER, COMBINATION STARTER, MACHINERY DISCONNECT FRN-R MODEL
$ 34.13
Part #:BUSS FRN-R-30

CLASS RK5 TYPE 2 INCH UL 248-12, CSA C22.2, CE APPROVAL 250 VAC/125 VDC VOLTAGE RATING 0.56 INCH DIAMETER 200 KILOAMPERE (SYMMETRICAL), 20 KILOAMPERE (DC) INTERRUPTING RATING 30 AMPERE CURRENT RATING FERRULE WITH GROOVED RING TERMINAL TYPE 10 SEC TIME DELAY (AT 500 PERCENT RATED LOAD), DUAL ELEMENT, NON-INDICATING CHARACTERISTICS FUSETRON[TM] BRAND APPLICATION POWER PANELBOARD, MOTOR CONTROL CENTER, COMBINATION STARTER, MACHINERY DISCONNECT SERIES FRN-R MODEL
$ 24.68
 
Displaying: 1 - 24 of 34 Matching Items